Evaluation of Current Hazardous Drug Exposure Control in Community Pharmacy.

IF 1.1 Q4 PHARMACOLOGY & PHARMACY
John Papastergiou, Tom Smiley
{"title":"Evaluation of Current Hazardous Drug Exposure Control in Community Pharmacy.","authors":"John Papastergiou,&nbsp;Tom Smiley","doi":"10.1177/87551225211072743","DOIUrl":null,"url":null,"abstract":"<p><p><b>Purpose</b>: To evaluate effectiveness of current hazardous drug exposure control practices in community pharmacies through identification of commonly contaminated surfaces. We also assessed the decontamination effectiveness of 5 different cleaning agents. <b>Methods</b>: This study was prospective and nonrandomized and conducted in 2 phases. In phase 1, 15 common areas used in the dispensing process were tested at each of 4 pharmacies in Toronto Ontario, Canada. Testing was conducted using the BD<sup>®</sup> HD Check System, a rapid, point-of-care, hazardous drug detection system that is able to identify contamination with methotrexate (MTX) and cyclophosphamide (CYP) and doxorubicin. In phase 2, 5 different cleaning agents (70% isopropyl alcohol, Lysol<sup>®</sup> spray, Ecolab<sup>®</sup> retail multiquat sanitizer, Ecolab retail multisurface and glass cleaner with peroxide, and Ecolab QSR heavy-duty degreaser) were tested for their ability to eliminate contamination. <b>Results</b>: All 4 pharmacies tested positive for contamination with MTX (25.8% of surfaces). Contamination with CYP was less frequent, with only 3 sites and 18.2% of surfaces testing positive. Of the 5 cleaning agents tested, only Ecolab QSR heavy-duty degreaser was able to eliminate contamination with MTX. None of the agents were successful against CYP. <b>Conclusions:</b> The results illustrate an unacceptable prevalence of hazardous drug contamination in community pharmacy settings. The BD HD Check System can serve to rapidly detect common high-risk areas for surface contamination. Decontamination protocols against MTX may include Ecolab QSR heavy-duty degreaser. Novel agents must be identified to remove contamination caused by CYP.</p>","PeriodicalId":16796,"journal":{"name":"Journal of Pharmacy Technology","volume":null,"pages":null},"PeriodicalIF":1.1000,"publicationDate":"2022-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9116126/pdf/10.1177_87551225211072743.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Pharmacy Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/87551225211072743","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"PHARMACOLOGY & PHARMACY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To evaluate effectiveness of current hazardous drug exposure control practices in community pharmacies through identification of commonly contaminated surfaces. We also assessed the decontamination effectiveness of 5 different cleaning agents. Methods: This study was prospective and nonrandomized and conducted in 2 phases. In phase 1, 15 common areas used in the dispensing process were tested at each of 4 pharmacies in Toronto Ontario, Canada. Testing was conducted using the BD® HD Check System, a rapid, point-of-care, hazardous drug detection system that is able to identify contamination with methotrexate (MTX) and cyclophosphamide (CYP) and doxorubicin. In phase 2, 5 different cleaning agents (70% isopropyl alcohol, Lysol® spray, Ecolab® retail multiquat sanitizer, Ecolab retail multisurface and glass cleaner with peroxide, and Ecolab QSR heavy-duty degreaser) were tested for their ability to eliminate contamination. Results: All 4 pharmacies tested positive for contamination with MTX (25.8% of surfaces). Contamination with CYP was less frequent, with only 3 sites and 18.2% of surfaces testing positive. Of the 5 cleaning agents tested, only Ecolab QSR heavy-duty degreaser was able to eliminate contamination with MTX. None of the agents were successful against CYP. Conclusions: The results illustrate an unacceptable prevalence of hazardous drug contamination in community pharmacy settings. The BD HD Check System can serve to rapidly detect common high-risk areas for surface contamination. Decontamination protocols against MTX may include Ecolab QSR heavy-duty degreaser. Novel agents must be identified to remove contamination caused by CYP.

社区药房危险药物暴露控制现状评价。
目的:通过识别常见污染表面,评价当前社区药房危险药物暴露控制措施的有效性。我们还评估了5种不同清洗剂的去污效果。方法:本研究为前瞻性非随机研究,分2期进行。在第一阶段,在加拿大安大略省多伦多市的4家药房分别对配药过程中使用的15个公共区域进行了测试。测试使用BD®HD检查系统进行,这是一种快速、即时、危险药物检测系统,能够识别甲氨蝶呤(MTX)、环磷酰胺(CYP)和阿霉素的污染。在第2阶段,测试了5种不同的清洗剂(70%异丙醇、来索尔®喷雾、艺康®零售多季消毒液、艺康®零售多表面和含过氧化氢的玻璃清洗剂以及艺康QSR重型脱脂剂)消除污染的能力。结果:4家药店均检测出甲氨蝶呤污染阳性(25.8%)。CYP污染较少,只有3个位点和18.2%的表面检测呈阳性。在测试的5种清洗剂中,只有艺康QSR重型脱脂剂能够消除MTX的污染。没有一种药物对CYP有效。结论:结果表明,在社区药房环境中,危险药物污染的流行程度是不可接受的。屋宇署检查系统可迅速侦测常见的表面污染高危区域。针对MTX的净化方案可能包括艺康QSR重型脱脂剂。必须确定新的药剂来去除CYP引起的污染。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Pharmacy Technology
Journal of Pharmacy Technology PHARMACOLOGY & PHARMACY-
CiteScore
1.50
自引率
0.00%
发文量
49
期刊介绍: For both pharmacists and technicians, jPT provides valuable information for those interested in the entire body of pharmacy practice. jPT covers new drugs, products, and equipment; therapeutic trends; organizational, legal, and educational activities; drug distribution and administration; and includes continuing education articles.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信