N-Butyl Cyanoacrylate Glue Versus Nonspherical Polyvinyl Alcohol Particles For Prostatic Arterial Embolization To Treat Benign Prostatic Hyperplasia: Safety and Efficacy.

IF 1.5 4区 医学 Q3 UROLOGY & NEPHROLOGY
Bilal Ahmad Hijazi, Hai-Bin Shi, Sheng Liu, Turki A Alqurashi, Zakir J Sabri
{"title":"N-Butyl Cyanoacrylate Glue Versus Nonspherical Polyvinyl Alcohol Particles For Prostatic Arterial Embolization To Treat Benign Prostatic Hyperplasia: Safety and Efficacy.","authors":"Bilal Ahmad Hijazi,&nbsp;Hai-Bin Shi,&nbsp;Sheng Liu,&nbsp;Turki A Alqurashi,&nbsp;Zakir J Sabri","doi":"10.22037/uj.v20i.7734","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Our aim is to compare N-butyl cyanoacrylate (NBCA) glue and non-spherical polyvinyl alcohol (PVA) particles for prostatic artery embolization (PAE) for patients with benign prostatic hyperplasia (BPH) to treat lower urinary tract symptoms (LUTS) and report their feasibility, safety, and short-term effectiveness.</p><p><strong>Materials and methods: </strong>110 patients (mean age: 72.6 years) with BPH related to LUTS were divided into two groups, PAE was performed in one group with 250 - 355 μm non-spherical PVA particles. Whereas, the other group received a mixture of NBCA glue/ lipiodol for PAE.</p><p><strong>Results: </strong>PAE was technically successful in all 110 patients (100 %). During 6 months follow up, we found that in patients who received NBCA glue, the mean of prostatic volume (PV) was significantly reduced compared to baseline (67.1 ± 8.5 to 40.2 ± 5.4), International Prostate Symptom Score (IPSS) (25.7 ± 4.3 to 7.2 ± 1.09), Quality of life (QoL) (4.43 ± 0.27 to 1.58 ± 2.27); whereas, the mean of Peak urinary flow (Qmax) increased significantly from baseline to 6 months (8.6 ± 2.3 to 15.4 ± 2.3), International Index of Erectile Function (IIEFS) (9.46 ± 1.51 to 19.3 ± 1.33). Meanwhile, non-spherical PVA particles used in the other group show that PV significantly reduced from baseline to 6 months (68.2 ± 8.32 to 38.8 ± 6.13), IPSS (25.0 ± 3.59 to7.24 ± 0.83), QoL (4.43 ± 0.24 to1.56 ± 0.55). The mean for Qmax increased from baseline to 6 months (7.19 ± 1.67 to15.1 ± 2.42), IIEFS (9.22 ± 1.30 to 19.5 ± 0.96).</p><p><strong>Conclusion: </strong>PAE with NBCA glue and non-spherical PVA particles is feasible, safe, and effective for patients with BPH related-LUTS. This gives the physicians options to choose between embolizing agents based on the architecture of the prostatic artery.</p>","PeriodicalId":23416,"journal":{"name":"Urology Journal","volume":null,"pages":null},"PeriodicalIF":1.5000,"publicationDate":"2023-07-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Urology Journal","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.22037/uj.v20i.7734","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"UROLOGY & NEPHROLOGY","Score":null,"Total":0}
引用次数: 2

Abstract

Purpose: Our aim is to compare N-butyl cyanoacrylate (NBCA) glue and non-spherical polyvinyl alcohol (PVA) particles for prostatic artery embolization (PAE) for patients with benign prostatic hyperplasia (BPH) to treat lower urinary tract symptoms (LUTS) and report their feasibility, safety, and short-term effectiveness.

Materials and methods: 110 patients (mean age: 72.6 years) with BPH related to LUTS were divided into two groups, PAE was performed in one group with 250 - 355 μm non-spherical PVA particles. Whereas, the other group received a mixture of NBCA glue/ lipiodol for PAE.

Results: PAE was technically successful in all 110 patients (100 %). During 6 months follow up, we found that in patients who received NBCA glue, the mean of prostatic volume (PV) was significantly reduced compared to baseline (67.1 ± 8.5 to 40.2 ± 5.4), International Prostate Symptom Score (IPSS) (25.7 ± 4.3 to 7.2 ± 1.09), Quality of life (QoL) (4.43 ± 0.27 to 1.58 ± 2.27); whereas, the mean of Peak urinary flow (Qmax) increased significantly from baseline to 6 months (8.6 ± 2.3 to 15.4 ± 2.3), International Index of Erectile Function (IIEFS) (9.46 ± 1.51 to 19.3 ± 1.33). Meanwhile, non-spherical PVA particles used in the other group show that PV significantly reduced from baseline to 6 months (68.2 ± 8.32 to 38.8 ± 6.13), IPSS (25.0 ± 3.59 to7.24 ± 0.83), QoL (4.43 ± 0.24 to1.56 ± 0.55). The mean for Qmax increased from baseline to 6 months (7.19 ± 1.67 to15.1 ± 2.42), IIEFS (9.22 ± 1.30 to 19.5 ± 0.96).

Conclusion: PAE with NBCA glue and non-spherical PVA particles is feasible, safe, and effective for patients with BPH related-LUTS. This gives the physicians options to choose between embolizing agents based on the architecture of the prostatic artery.

正丁基氰基丙烯酸酯胶与非球形聚乙烯醇颗粒前列腺动脉栓塞治疗良性前列腺增生:安全性和有效性。
目的:比较正丁基氰基丙烯酸酯(NBCA)胶和非球形聚乙烯醇(PVA)颗粒用于前列腺动脉栓塞(PAE)治疗良性前列腺增生(BPH)患者下尿路症状(LUTS)的可行性、安全性和短期疗效。材料与方法:将110例LUTS相关BPH患者(平均年龄72.6岁)分为两组,一组采用250 ~ 355 μm非球形PVA颗粒进行PAE;另一组采用NBCA胶/脂醇混合治疗PAE。结果:110例患者(100%)PAE技术成功。在6个月的随访中,我们发现,与基线相比,接受NBCA胶的患者前列腺体积(PV)平均值(67.1±8.5至40.2±5.4),国际前列腺症状评分(IPSS)(25.7±4.3至7.2±1.09),生活质量(QoL)(4.43±0.27至1.58±2.27)显著降低;而尿流量峰值平均值(Qmax)在6个月内从基线(8.6±2.3)增加到15.4±2.3),国际勃起功能指数(IIEFS)从9.46±1.51增加到19.3±1.33。与此同时,另一组使用非球形PVA颗粒,在6个月内PV从基线(68.2±8.32至38.8±6.13),IPSS(25.0±3.59至7.24±0.83),生活质量(4.43±0.24至1.56±0.55)显著降低。Qmax的平均值从基线增加到6个月(7.19±1.67至15.1±2.42),IIEFS从9.22±1.30至19.5±0.96)。结论:应用NBCA胶和非球形PVA颗粒进行PAE治疗前列腺增生相关luts是可行、安全、有效的。这使得医生可以根据前列腺动脉的结构选择栓塞剂。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Urology Journal
Urology Journal UROLOGY & NEPHROLOGY-
CiteScore
2.60
自引率
6.70%
发文量
44
审稿时长
6-12 weeks
期刊介绍: As the official journal of the Urology and Nephrology Research Center (UNRC) and the Iranian Urological Association (IUA), Urology Journal is a comprehensive digest of useful information on modern urology. Emphasis is on practical information that reflects the latest diagnostic and treatment techniques. Our objectives are to provide an exceptional source of current and clinically relevant research in the discipline of urology, to reflect the scientific work and progress of our colleagues, and to present the articles in a logical, timely, and concise format that meets the diverse needs of today’s urologist. Urology Journal publishes manuscripts on urology and kidney transplantation, all of which undergo extensive peer review by recognized authorities in the field prior to their acceptance for publication. Accordingly, original articles, case reports, and letters to editor are encouraged.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信