Short-pulse laser plus subthreshold diffuse laser for serous retinal detachment in dome-shaped macula.

IF 1.9 Q2 OPHTHALMOLOGY
Murilo Wendeborn Rodrigues, Thais Bastos, Annelise Nicotti Gonçalves, José Augusto Cardillo, André Messias, Eduardo Cunha de Souza, Rodrigo Jorge
{"title":"Short-pulse laser plus subthreshold diffuse laser for serous retinal detachment in dome-shaped macula.","authors":"Murilo Wendeborn Rodrigues, Thais Bastos, Annelise Nicotti Gonçalves, José Augusto Cardillo, André Messias, Eduardo Cunha de Souza, Rodrigo Jorge","doi":"10.1186/s40942-023-00483-8","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>First described by Gaucher and associates in 2008, dome-shaped macula (DSM) is an anterior convex protrusion of the macula visible on OCT (optical coherence tomography). Visual impairment in DSM results mainly from sub-foveal serous retinal detachment (SRD). Herein, this original study from retrospective data analysis evaluate the anatomical and functional effects of Pascal<sup>®</sup> short-pulse (SP) laser plus endpoint management (EpM) subthreshold diffuse laser (SDL) in patients with SRD due to DSM.</p><p><strong>Methods: </strong>This retrospective study included seven consecutive patients (eight eyes) with SRD secondary to dome-shaped macula who underwent a comprehensive ophthalmological evaluation including logMAR BCVA, slit-lamp biomicroscopy, indirect ophthalmoscopy, and spectral-domain optical coherence tomography (SD-OCT) (Spectralis; Heidelberg Engineering, Germany) before combined Pascal<sup>®</sup> SP laser plus EpM-SDL with 1 to 6 month intervals, postoperatively, with a mean ± standard error (SE) follow-up time of 12.92 ± 1.34 months.</p><p><strong>Results: </strong>Eight eyes from seven patients were analyzed in this study. At baseline, mean BCVA (LogMAR) ± standard error (SE) and mean CST (central subfield thickness)(µm) ± SE were 0.6125 ± 0.14 and 412.50 ± 24.65, respectively. After a mean follow-up time of 12.92 ± 1.34 months, mean CST (µm) ± SE and BCVA (LogMAR) ± SE were 294.75 ± 19.68 (p = 0.0078) and 0.4537 ± 0.12 (p = 0.0313), respectively. A statistically significant reduction in mean CST and an improvement in mean BCVA were noted after SRD resolution with laser therapy application. The mean serous retinal detachment resolution time (months) ± SE was 3.75 ± 1.08. No adverse events were registered, including enlargement of atrophic alterations and choroidal neovascularization.</p><p><strong>Conclusions: </strong>The novel combined laser modality with Pascal<sup>®</sup> SP laser plus EpM-SDL treatment may induce subretinal fluid regression and BCVA improvement 1 year after treatment in DSM patients with SRD.</p>","PeriodicalId":14289,"journal":{"name":"International Journal of Retina and Vitreous","volume":null,"pages":null},"PeriodicalIF":1.9000,"publicationDate":"2023-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10474725/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Retina and Vitreous","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/s40942-023-00483-8","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: First described by Gaucher and associates in 2008, dome-shaped macula (DSM) is an anterior convex protrusion of the macula visible on OCT (optical coherence tomography). Visual impairment in DSM results mainly from sub-foveal serous retinal detachment (SRD). Herein, this original study from retrospective data analysis evaluate the anatomical and functional effects of Pascal® short-pulse (SP) laser plus endpoint management (EpM) subthreshold diffuse laser (SDL) in patients with SRD due to DSM.

Methods: This retrospective study included seven consecutive patients (eight eyes) with SRD secondary to dome-shaped macula who underwent a comprehensive ophthalmological evaluation including logMAR BCVA, slit-lamp biomicroscopy, indirect ophthalmoscopy, and spectral-domain optical coherence tomography (SD-OCT) (Spectralis; Heidelberg Engineering, Germany) before combined Pascal® SP laser plus EpM-SDL with 1 to 6 month intervals, postoperatively, with a mean ± standard error (SE) follow-up time of 12.92 ± 1.34 months.

Results: Eight eyes from seven patients were analyzed in this study. At baseline, mean BCVA (LogMAR) ± standard error (SE) and mean CST (central subfield thickness)(µm) ± SE were 0.6125 ± 0.14 and 412.50 ± 24.65, respectively. After a mean follow-up time of 12.92 ± 1.34 months, mean CST (µm) ± SE and BCVA (LogMAR) ± SE were 294.75 ± 19.68 (p = 0.0078) and 0.4537 ± 0.12 (p = 0.0313), respectively. A statistically significant reduction in mean CST and an improvement in mean BCVA were noted after SRD resolution with laser therapy application. The mean serous retinal detachment resolution time (months) ± SE was 3.75 ± 1.08. No adverse events were registered, including enlargement of atrophic alterations and choroidal neovascularization.

Conclusions: The novel combined laser modality with Pascal® SP laser plus EpM-SDL treatment may induce subretinal fluid regression and BCVA improvement 1 year after treatment in DSM patients with SRD.

Abstract Image

Abstract Image

Abstract Image

短脉冲激光加阈下扩散激光治疗穹状黄斑浆液性视网膜脱离。
背景:2008年,Gaucher及其同事首次描述了圆顶状黄斑(DSM),它是在OCT(光学相干断层扫描)上可见的黄斑的前凸突出。DSM的视力损害主要由中央凹下浆液性视网膜脱离(SRD)引起。本研究通过回顾性数据分析,评估Pascal®短脉冲(SP)激光加终点管理(EpM)阈下漫射激光(SDL)治疗因DSM导致的SRD患者的解剖和功能影响。方法:本回顾性研究纳入了连续7例(8只眼)继发于穹状黄斑的SRD患者,他们接受了全面的眼科评估,包括logMAR BCVA、裂隙灯生物显微镜、间接眼科检查和光谱域光学相干断层扫描(SD-OCT) (Spectralis;Pascal®SP激光联合EpM-SDL前,术后间隔1 ~ 6个月,平均±标准误差(SE)随访时间为12.92±1.34个月。结果:本研究分析了7例患者的8只眼。基线时,平均BCVA (LogMAR)±标准误差(SE)和平均CST(中心子场厚度)(µm)±SE分别为0.6125±0.14和412.50±24.65。平均随访12.92±1.34个月后,平均CST(µm)±SE为294.75±19.68 (p = 0.0078), BCVA (LogMAR)±SE为0.4537±0.12 (p = 0.0313)。应用激光治疗解决SRD后,平均CST降低和平均BCVA改善具有统计学意义。浆液性视网膜脱离的平均分辨时间(月)±SE为3.75±1.08。没有记录到不良事件,包括萎缩变大和脉络膜新生血管。结论:Pascal®SP激光加EpM-SDL治疗的新型联合激光治疗方式可诱导DSM合并SRD患者治疗1年后视网膜下液消退和BCVA改善。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.50
自引率
4.30%
发文量
81
审稿时长
19 weeks
期刊介绍: International Journal of Retina and Vitreous focuses on the ophthalmic subspecialty of vitreoretinal disorders. The journal presents original articles on new approaches to diagnosis, outcomes of clinical trials, innovations in pharmacological therapy and surgical techniques, as well as basic science advances that impact clinical practice. Topical areas include, but are not limited to: -Imaging of the retina, choroid and vitreous -Innovations in optical coherence tomography (OCT) -Small-gauge vitrectomy, retinal detachment, chromovitrectomy -Electroretinography (ERG), microperimetry, other functional tests -Intraocular tumors -Retinal pharmacotherapy & drug delivery -Diabetic retinopathy & other vascular diseases -Age-related macular degeneration (AMD) & other macular entities
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信