{"title":"Surgical Technique: Lateral Plate Osteosynthesis of Proximal Phalanx Fractures.","authors":"Zhixue Lim, Anthony Tun Lin Foo, Soumen Das De","doi":"10.1097/BTH.0000000000000407","DOIUrl":null,"url":null,"abstract":"<p><p>Dorsal plate fixation of proximal phalanx (PP) fractures is a conventional approach but interferes with the extensor mechanism and results in stiffness. Biomechanical studies have shown that laterally placed plates on the proximal phalanges are equally stable and rigid. This technique obviates the issue of tendon adhesion and may result in better postoperative range of motion and lower secondary procedures such as removal of implant and tenolysis. The low adoption of this technique may be related to lack of familiarity with the surgical approach. We describe our surgical technique with lateral plating of PP fractures and present our case that lateral plate osteosynthesis is an acceptable surgical fixation option for PP fractures, which extends the hand surgeon's armamentarium for more challenging and comminuted fractures.</p>","PeriodicalId":39303,"journal":{"name":"Techniques in Hand and Upper Extremity Surgery","volume":"27 1","pages":"38-44"},"PeriodicalIF":0.0000,"publicationDate":"2023-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Techniques in Hand and Upper Extremity Surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/BTH.0000000000000407","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0
Abstract
Dorsal plate fixation of proximal phalanx (PP) fractures is a conventional approach but interferes with the extensor mechanism and results in stiffness. Biomechanical studies have shown that laterally placed plates on the proximal phalanges are equally stable and rigid. This technique obviates the issue of tendon adhesion and may result in better postoperative range of motion and lower secondary procedures such as removal of implant and tenolysis. The low adoption of this technique may be related to lack of familiarity with the surgical approach. We describe our surgical technique with lateral plating of PP fractures and present our case that lateral plate osteosynthesis is an acceptable surgical fixation option for PP fractures, which extends the hand surgeon's armamentarium for more challenging and comminuted fractures.
期刊介绍:
Techniques in Hand & Upper Extremity Surgery presents authoritative, practical information on today"s advances in hand and upper extremity surgery. It features articles by leading experts on the latest surgical techniques, the newest equipment, and progress in therapies for rehabilitation. The primary focus of the journal is hand surgery, but articles on the wrist, elbow, and shoulder are also included. Major areas covered include arthroscopy, microvascular surgery, plastic surgery, congenital anomalies, tendon and nerve disorders, trauma, and work-related injuries.