Alina Ariceta, Mirian Elizabeth Casco, Paula Kurlander, Francisca Forti, Antonion Camarano, Roberto Volfovicz, Hsun-Lian Chan, Diego Velásquez-Plata
{"title":"Performance and Strength Characteristics of Suture Knots in Periodontal Microsurgery: An In Vitro Study.","authors":"Alina Ariceta, Mirian Elizabeth Casco, Paula Kurlander, Francisca Forti, Antonion Camarano, Roberto Volfovicz, Hsun-Lian Chan, Diego Velásquez-Plata","doi":"10.11607/prd.6899","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>This study is aimed to investigate the types of knot failure (untying or breaking) and the tension required to break different sutures diameters.</p><p><strong>Methods: </strong>One hundred and fifty knots were fabricated using polyamide sutures diameters of 6/0, 7/0, and 8/0. The studied knots were either squared or slipped with different numbers of throws (2, 3, 4, 5 and 6), and the following data were recorded: type of failure (untied or broken), number of throws, the tension required to untie or break each knot, slippage, and elongation of the knot. The knots were created in a standardized way. with a device and weights and then subjected to a controlled tension.</p><p><strong>Results: </strong>The knots that got untied were: 1=1, 1x1, 2=1, and 2x1, whereas the remaining knots got broken. Notably, at least three throws were required to prevent untying, but separately, as in 1=1=1 or 1x1x1. The mean tension to break the knots of 6/0, 7/0, and 8/0 sutures were 3.1, 1.3, and 0.6 N, respectively (P < 0.05), and they were independent of the knot type.</p><p><strong>Conclusion: </strong>Results from this study demonstrated that the knots with geometries of 2=2/2x2 and 1=1=1/1x1x1 were secure, and additional throws does not increase their security. Furthermore, tensile strength reduces with decreased suture size.</p>","PeriodicalId":54948,"journal":{"name":"International Journal of Periodontics & Restorative Dentistry","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2023-08-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Periodontics & Restorative Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.11607/prd.6899","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0
Abstract
Background: This study is aimed to investigate the types of knot failure (untying or breaking) and the tension required to break different sutures diameters.
Methods: One hundred and fifty knots were fabricated using polyamide sutures diameters of 6/0, 7/0, and 8/0. The studied knots were either squared or slipped with different numbers of throws (2, 3, 4, 5 and 6), and the following data were recorded: type of failure (untied or broken), number of throws, the tension required to untie or break each knot, slippage, and elongation of the knot. The knots were created in a standardized way. with a device and weights and then subjected to a controlled tension.
Results: The knots that got untied were: 1=1, 1x1, 2=1, and 2x1, whereas the remaining knots got broken. Notably, at least three throws were required to prevent untying, but separately, as in 1=1=1 or 1x1x1. The mean tension to break the knots of 6/0, 7/0, and 8/0 sutures were 3.1, 1.3, and 0.6 N, respectively (P < 0.05), and they were independent of the knot type.
Conclusion: Results from this study demonstrated that the knots with geometries of 2=2/2x2 and 1=1=1/1x1x1 were secure, and additional throws does not increase their security. Furthermore, tensile strength reduces with decreased suture size.
期刊介绍:
The International Journal of Periodontics & Restorative Dentistry will
publish manuscripts concerned with all aspects of clinical periodontology,
restorative dentistry, and implantology. This includes pertinent research
as well as clinical methodology (their interdependence and relationship
should be addressed where applicable); proceedings of relevant symposia
or conferences; and quality review papers. Original manuscripts are considered for publication on the condition that they have not been published
or submitted for publication elsewhere.