John Kenneth Leypoldt, Mauro Pietribiasi, Malgorzata Debowska, Monika Wieliczko, Malgorzata Twardowska-Kawalec, Jolanta Malyszko, Jacek Waniewski
{"title":"Validity of the hydrogen ion mobilisation model during haemodialysis with time-dependent dialysate bicarbonate concentrations.","authors":"John Kenneth Leypoldt, Mauro Pietribiasi, Malgorzata Debowska, Monika Wieliczko, Malgorzata Twardowska-Kawalec, Jolanta Malyszko, Jacek Waniewski","doi":"10.1177/03913988231179233","DOIUrl":null,"url":null,"abstract":"Background: The hydrogen ion (H+) mobilisation model has been previously shown to accurately describe blood bicarbonate (HCO3) kinetics during haemodialysis (HD) when the dialysate bicarbonate concentration ([HCO3]) is constant throughout the treatment. This study evaluated the ability of the H+ mobilization model to describe blood HCO3 kinetics during HD treatments with a time-dependent dialysate [HCO3]. Methods: Data from a recent clinical study where blood [HCO3] was measured at the beginning of and every hour during 4-h treatments in 20 chronic, thrice-weekly HD patients with a constant (Treatment A), decreasing (Treatment B) and increasing (Treatment C) dialysate [HCO3] were evaluated. The H+ mobilization model was used to determine the model parameter (Hm) that provided the best fit of the model to the clinical data using nonlinear regression. A total of 114 HD treatments provided individual estimates of Hm. Results: Mean ± standard deviation estimates of Hm during Treatments A, B and C were 0.153 ± 0.069, 0.180 ± 0.109 and 0.205 ± 0.141 L/min (medians [interquartile ranges] were 0.145 [0.118,0.191], 0.159 [0.112,0.209], 0.169 [0.115,0.236] L/min), respectively; these estimates were not different from each other (p = 0.26). The sum of squared differences between the measured blood [HCO3] and that predicted by the model were not different during Treatments A, B and C (p = 0.50), suggesting a similar degree of model fit to the data. Conclusions: This study supports the validity of the H+ mobilization model to describe intradialysis blood HCO3 kinetics during HD with a constant Hm value when using a time-dependent dialysate [HCO3].","PeriodicalId":13932,"journal":{"name":"International Journal of Artificial Organs","volume":null,"pages":null},"PeriodicalIF":1.4000,"publicationDate":"2023-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Artificial Organs","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1177/03913988231179233","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Background: The hydrogen ion (H+) mobilisation model has been previously shown to accurately describe blood bicarbonate (HCO3) kinetics during haemodialysis (HD) when the dialysate bicarbonate concentration ([HCO3]) is constant throughout the treatment. This study evaluated the ability of the H+ mobilization model to describe blood HCO3 kinetics during HD treatments with a time-dependent dialysate [HCO3]. Methods: Data from a recent clinical study where blood [HCO3] was measured at the beginning of and every hour during 4-h treatments in 20 chronic, thrice-weekly HD patients with a constant (Treatment A), decreasing (Treatment B) and increasing (Treatment C) dialysate [HCO3] were evaluated. The H+ mobilization model was used to determine the model parameter (Hm) that provided the best fit of the model to the clinical data using nonlinear regression. A total of 114 HD treatments provided individual estimates of Hm. Results: Mean ± standard deviation estimates of Hm during Treatments A, B and C were 0.153 ± 0.069, 0.180 ± 0.109 and 0.205 ± 0.141 L/min (medians [interquartile ranges] were 0.145 [0.118,0.191], 0.159 [0.112,0.209], 0.169 [0.115,0.236] L/min), respectively; these estimates were not different from each other (p = 0.26). The sum of squared differences between the measured blood [HCO3] and that predicted by the model were not different during Treatments A, B and C (p = 0.50), suggesting a similar degree of model fit to the data. Conclusions: This study supports the validity of the H+ mobilization model to describe intradialysis blood HCO3 kinetics during HD with a constant Hm value when using a time-dependent dialysate [HCO3].
期刊介绍:
The International Journal of Artificial Organs (IJAO) publishes peer-reviewed research and clinical, experimental and theoretical, contributions to the field of artificial, bioartificial and tissue-engineered organs. The mission of the IJAO is to foster the development and optimization of artificial, bioartificial and tissue-engineered organs, for implantation or use in procedures, to treat functional deficits of all human tissues and organs.