Effect of Temporal Sampling Rate on Estimates of the Perfusion Parameters for Patients with Moyamoya Disease Assessed with Simultaneous Multislice Dynamic Susceptibility Contrast-enhanced MR Imaging.
IF 2.5 3区 医学Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
{"title":"Effect of Temporal Sampling Rate on Estimates of the Perfusion Parameters for Patients with Moyamoya Disease Assessed with Simultaneous Multislice Dynamic Susceptibility Contrast-enhanced MR Imaging.","authors":"Tomohiro Takamura, Shoko Hara, Tadashi Nariai, Yutaka Ikenouchi, Michimasa Suzuki, Toshiaki Taoka, Masahiro Ida, Keiichi Ishigame, Masaaki Hori, Kanako Sato, Koji Kamagata, Kanako Kumamaru, Hidenori Oishi, Sho Okamoto, Yoshio Araki, Kenji Uda, Masakazu Miyajima, Taketoshi Maehara, Motoki Inaji, Yoji Tanaka, Shinji Naganawa, Hisashi Kawai, Toshiki Nakane, Yasuaki Tsurushima, Toshiyuki Onodera, Shuko Nojiri, Shigeki Aoki","doi":"10.2463/mrms.mp.2021-0162","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The effect of temporal sampling rate (TSR) on perfusion parameters has not been fully investigated in Moyamoya disease (MMD); therefore, this study evaluated the influence of different TSRs on perfusion parameters quantitatively and qualitatively by applying simultaneous multi-slice (SMS) dynamic susceptibility contrast-enhanced MR imaging (DSC-MRI).</p><p><strong>Methods: </strong>DSC-MRI datasets were acquired from 28 patients with MMD with a TSR of 0.5 s. Cerebral blood flow (CBF), cerebral blood volume (CBV), mean transit time (MTT), time to peak (TTP), and time to maximum tissue residue function (Tmax) were calculated for eight TSRs ranging from 0.5 to 4.0 s in 0.5-s increments that were subsampled from a TSR of 0.5 s datasets. Perfusion measurements and volume for chronic ischemic (Tmax ≥ 2 s) and non-ischemic (Tmax < 2 s) areas for each TSR were compared to measurements with a TSR of 0.5 s, as was visual perfusion map analysis.</p><p><strong>Results: </strong>CBF, CBV, and Tmax values tended to be underestimated, whereas MTT and TTP values were less influenced, with a longer TSR. Although Tmax values were overestimated in the TSR of 1.0 s in non-ischemic areas, differences in perfusion measurements between the TSRs of 0.5 and 1.0 s were generally minimal. The volumes of the chronic ischemic areas with a TSR ≥ 3.0 s were significantly underestimated. In CBF and CBV maps, no significant deterioration was noted in image quality up to 3.0 and 2.5 s, respectively. The image quality of MTT, TTP, and Tmax maps for the TSR of 1.0 s was similar to that for the TSR of 0.5 s but was significantly deteriorated for the TSRs of ≥ 1.5 s.</p><p><strong>Conclusion: </strong>In the assessment of MMD by SMS DSC-MRI, application of TSRs of ≥ 1.5 s may lead to deterioration of the perfusion measurements; however, that was less influenced in TSRs of ≤ 1.0 s.</p>","PeriodicalId":18119,"journal":{"name":"Magnetic Resonance in Medical Sciences","volume":"22 3","pages":"301-312"},"PeriodicalIF":2.5000,"publicationDate":"2023-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/5a/1b/mrms-22-301.PMC10449549.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Magnetic Resonance in Medical Sciences","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.2463/mrms.mp.2021-0162","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: The effect of temporal sampling rate (TSR) on perfusion parameters has not been fully investigated in Moyamoya disease (MMD); therefore, this study evaluated the influence of different TSRs on perfusion parameters quantitatively and qualitatively by applying simultaneous multi-slice (SMS) dynamic susceptibility contrast-enhanced MR imaging (DSC-MRI).
Methods: DSC-MRI datasets were acquired from 28 patients with MMD with a TSR of 0.5 s. Cerebral blood flow (CBF), cerebral blood volume (CBV), mean transit time (MTT), time to peak (TTP), and time to maximum tissue residue function (Tmax) were calculated for eight TSRs ranging from 0.5 to 4.0 s in 0.5-s increments that were subsampled from a TSR of 0.5 s datasets. Perfusion measurements and volume for chronic ischemic (Tmax ≥ 2 s) and non-ischemic (Tmax < 2 s) areas for each TSR were compared to measurements with a TSR of 0.5 s, as was visual perfusion map analysis.
Results: CBF, CBV, and Tmax values tended to be underestimated, whereas MTT and TTP values were less influenced, with a longer TSR. Although Tmax values were overestimated in the TSR of 1.0 s in non-ischemic areas, differences in perfusion measurements between the TSRs of 0.5 and 1.0 s were generally minimal. The volumes of the chronic ischemic areas with a TSR ≥ 3.0 s were significantly underestimated. In CBF and CBV maps, no significant deterioration was noted in image quality up to 3.0 and 2.5 s, respectively. The image quality of MTT, TTP, and Tmax maps for the TSR of 1.0 s was similar to that for the TSR of 0.5 s but was significantly deteriorated for the TSRs of ≥ 1.5 s.
Conclusion: In the assessment of MMD by SMS DSC-MRI, application of TSRs of ≥ 1.5 s may lead to deterioration of the perfusion measurements; however, that was less influenced in TSRs of ≤ 1.0 s.
期刊介绍:
Magnetic Resonance in Medical Sciences (MRMS or Magn
Reson Med Sci) is an international journal pursuing the
publication of original articles contributing to the progress
of magnetic resonance in the field of biomedical sciences
including technical developments and clinical applications.
MRMS is an official journal of the Japanese Society for
Magnetic Resonance in Medicine (JSMRM).