Carbon dots derived from citric acid and urea as fluorometric probe for determining melamine contamination in infant formula sample.

IF 2.4 3区 化学 Q3 CHEMISTRY, ANALYTICAL
Souliyanh Phimmasone, Pornthip Boonsri, Weena Siangproh, Nuanlaor Ratanawimarnwong, Piyada Jittangprasert, Thitirat Mantim, Nunticha Limchoowong, Kriangsak Songsrirote
{"title":"Carbon dots derived from citric acid and urea as fluorometric probe for determining melamine contamination in infant formula sample.","authors":"Souliyanh Phimmasone,&nbsp;Pornthip Boonsri,&nbsp;Weena Siangproh,&nbsp;Nuanlaor Ratanawimarnwong,&nbsp;Piyada Jittangprasert,&nbsp;Thitirat Mantim,&nbsp;Nunticha Limchoowong,&nbsp;Kriangsak Songsrirote","doi":"10.1088/2050-6120/acf547","DOIUrl":null,"url":null,"abstract":"<p><p>Melamine has been intentionally added into food products to increase the protein count at less cost, especially in dairy products for infant resulting in serious adverse effects on health of consumers. Therefore, this study aimed to develop a method to quantify melamine in dairy products based on the change of fluorescent properties of carbon dots (CDs) as sensing probe. CDs with green-fluorescent emission were synthesized from citric acid and urea under microwave irradiation. The synthesized CDs emitted fluorescence at the maximum wavelength of 538 nm with excitation wavelength of 410 nm. Thus, they provided high sensitivity and selectivity on melamine detection by which fluorescent emission of the CDs was increasingly quenched upon increasing melamine concentrations. Optimal conditions for melamine determination using the CDs was under pH 6, volume ratio between CDs and sample of 2:8 and reaction time of 15 min. The developed method provided high precision of melamine determination with less than 5% of %RSD (n = 5), wide detection range from 1.0 to 200.0 ppm, and high sensitivity with limit of detection (LOD) of 0.47 ppm and limit of quantification (LOQ) of 1.56 ppm, which is within the regulated level by the Food and Drug Administration of the United States for melamine in dairy products. Several analytical characterization techniques were conducted to elucidate the reaction mechanism between CDs and melamine, and the hydrogen bonding interaction was proposed.</p>","PeriodicalId":18596,"journal":{"name":"Methods and Applications in Fluorescence","volume":" ","pages":""},"PeriodicalIF":2.4000,"publicationDate":"2023-10-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Methods and Applications in Fluorescence","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1088/2050-6120/acf547","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Melamine has been intentionally added into food products to increase the protein count at less cost, especially in dairy products for infant resulting in serious adverse effects on health of consumers. Therefore, this study aimed to develop a method to quantify melamine in dairy products based on the change of fluorescent properties of carbon dots (CDs) as sensing probe. CDs with green-fluorescent emission were synthesized from citric acid and urea under microwave irradiation. The synthesized CDs emitted fluorescence at the maximum wavelength of 538 nm with excitation wavelength of 410 nm. Thus, they provided high sensitivity and selectivity on melamine detection by which fluorescent emission of the CDs was increasingly quenched upon increasing melamine concentrations. Optimal conditions for melamine determination using the CDs was under pH 6, volume ratio between CDs and sample of 2:8 and reaction time of 15 min. The developed method provided high precision of melamine determination with less than 5% of %RSD (n = 5), wide detection range from 1.0 to 200.0 ppm, and high sensitivity with limit of detection (LOD) of 0.47 ppm and limit of quantification (LOQ) of 1.56 ppm, which is within the regulated level by the Food and Drug Administration of the United States for melamine in dairy products. Several analytical characterization techniques were conducted to elucidate the reaction mechanism between CDs and melamine, and the hydrogen bonding interaction was proposed.

柠檬酸和尿素衍生的碳点作为荧光探针,用于测定婴儿配方奶粉样品中的三聚氰胺污染。
三聚氰胺被有意添加到食品中,以降低成本增加蛋白质含量,尤其是在婴儿乳制品中,这对消费者的健康造成了严重的不利影响。因此,本研究旨在开发一种基于碳点(CD)作为传感探针的荧光特性变化来定量乳制品中三聚氰胺的方法。以柠檬酸和尿素为原料,在微波辐射下合成了具有绿色荧光发射的CDs。合成的CDs在最大波长538nm处发射荧光,激发波长410nm。因此,它们对三聚氰胺检测提供了高灵敏度和选择性,通过该检测,随着三聚氰胺浓度的增加,CD的荧光发射越来越熄灭。用CDs测定三聚氰胺的最佳条件是pH为6,CDs与样品的体积比为2:8,反应时间为15min。该方法的三聚氰胺测定精度高,RSD小于5%(n=5),检测范围宽,从1.0到200.0ppm,灵敏度高,检测限(LOD)为0.47 ppm,定量限(LOQ)为1.56 ppm,在美国食品药品监督管理局对乳制品中三聚氰胺的监管水平内。采用多种分析表征技术来阐明CDs与三聚氰胺之间的反应机理,并提出了氢键相互作用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Methods and Applications in Fluorescence
Methods and Applications in Fluorescence CHEMISTRY, ANALYTICALCHEMISTRY, PHYSICAL&n-CHEMISTRY, PHYSICAL
CiteScore
6.20
自引率
3.10%
发文量
60
期刊介绍: Methods and Applications in Fluorescence focuses on new developments in fluorescence spectroscopy, imaging, microscopy, fluorescent probes, labels and (nano)materials. It will feature both methods and advanced (bio)applications and accepts original research articles, reviews and technical notes.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信