{"title":"Addressing inter-device variations in optical coherence tomography angiography: will image-to-image translation systems help?","authors":"Hosein Nouri, Reza Nasri, Seyed-Hossein Abtahi","doi":"10.1186/s40942-023-00491-8","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Optical coherence tomography angiography (OCTA) is an innovative technology providing visual and quantitative data on retinal microvasculature in a non-invasive manner.</p><p><strong>Main body: </strong>Due to variations in the technical specifications of different OCTA devices, there are significant inter-device differences in OCTA data, which can limit their comparability and generalizability. These variations can also result in a domain shift problem that may interfere with applicability of machine learning models on data obtained from different OCTA machines. One possible approach to address this issue may be unsupervised deep image-to-image translation leveraging systems such as Cycle-Consistent Generative Adversarial Networks (Cycle-GANs) and Denoising Diffusion Probabilistic Models (DDPMs). Through training on unpaired images from different device domains, Cycle-GANs and DDPMs may enable cross-domain translation of images. They have been successfully applied in various medical imaging tasks, including segmentation, denoising, and cross-modality image-to-image translation. In this commentary, we briefly describe how Cycle-GANs and DDPMs operate, and review the recent experiments with these models on medical and ocular imaging data. We then discuss the benefits of applying such techniques for inter-device translation of OCTA data and the potential challenges ahead.</p><p><strong>Conclusion: </strong>Retinal imaging technologies and deep learning-based domain adaptation techniques are rapidly evolving. We suggest exploring the potential of image-to-image translation methods in improving the comparability of OCTA data from different centers or devices. This may facilitate more efficient analysis of heterogeneous data and broader applicability of machine learning models trained on limited datasets in this field.</p>","PeriodicalId":14289,"journal":{"name":"International Journal of Retina and Vitreous","volume":null,"pages":null},"PeriodicalIF":1.9000,"publicationDate":"2023-08-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10466880/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Retina and Vitreous","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/s40942-023-00491-8","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Optical coherence tomography angiography (OCTA) is an innovative technology providing visual and quantitative data on retinal microvasculature in a non-invasive manner.
Main body: Due to variations in the technical specifications of different OCTA devices, there are significant inter-device differences in OCTA data, which can limit their comparability and generalizability. These variations can also result in a domain shift problem that may interfere with applicability of machine learning models on data obtained from different OCTA machines. One possible approach to address this issue may be unsupervised deep image-to-image translation leveraging systems such as Cycle-Consistent Generative Adversarial Networks (Cycle-GANs) and Denoising Diffusion Probabilistic Models (DDPMs). Through training on unpaired images from different device domains, Cycle-GANs and DDPMs may enable cross-domain translation of images. They have been successfully applied in various medical imaging tasks, including segmentation, denoising, and cross-modality image-to-image translation. In this commentary, we briefly describe how Cycle-GANs and DDPMs operate, and review the recent experiments with these models on medical and ocular imaging data. We then discuss the benefits of applying such techniques for inter-device translation of OCTA data and the potential challenges ahead.
Conclusion: Retinal imaging technologies and deep learning-based domain adaptation techniques are rapidly evolving. We suggest exploring the potential of image-to-image translation methods in improving the comparability of OCTA data from different centers or devices. This may facilitate more efficient analysis of heterogeneous data and broader applicability of machine learning models trained on limited datasets in this field.
期刊介绍:
International Journal of Retina and Vitreous focuses on the ophthalmic subspecialty of vitreoretinal disorders. The journal presents original articles on new approaches to diagnosis, outcomes of clinical trials, innovations in pharmacological therapy and surgical techniques, as well as basic science advances that impact clinical practice. Topical areas include, but are not limited to: -Imaging of the retina, choroid and vitreous -Innovations in optical coherence tomography (OCT) -Small-gauge vitrectomy, retinal detachment, chromovitrectomy -Electroretinography (ERG), microperimetry, other functional tests -Intraocular tumors -Retinal pharmacotherapy & drug delivery -Diabetic retinopathy & other vascular diseases -Age-related macular degeneration (AMD) & other macular entities