Jordan B. Fenlon MD, Geoff Nelson PhD, Kathlina M. Teague MS, Savannah Coleman MS, Dennis Shrieve MD, PhD, Jonathan Tward MD, PhD
{"title":"A Dosimetric Correlation Between Radiation Dose to Bone and Reduction of Hemoglobin Levels After Radiation Therapy for Prostate Cancer","authors":"Jordan B. Fenlon MD, Geoff Nelson PhD, Kathlina M. Teague MS, Savannah Coleman MS, Dennis Shrieve MD, PhD, Jonathan Tward MD, PhD","doi":"10.1016/j.ijrobp.2023.07.036","DOIUrl":null,"url":null,"abstract":"<div><h3>Purpose</h3><p>The aim of this work was to investigate the correlation between dose to pelvic bone marrow and anemia when treating prostate cancer (PC) with definitive radiation.</p></div><div><h3>Methods and Materials</h3><p><span>Patients were selected from a prospective institutional database of patients with PC treated between 2008 and 2021. Pelvic bone (L3/L4 interface through ischial tuberosities) was contoured, and the dose to this structure was calculated. Doses were converted to 2-Gy equivalent doses using an α/β of 10. Exploratory analysis suggested dichotomizing into low-volume exposures of ≤1000 cc (LVE) and high-volume exposures of >1000 cc (HVE). Nonparametric kernel regressions were performed evaluating the effects of time, dose, and </span>androgen deprivation therapy use on hemoglobin (Hgb) values. Reoptimization of plans was performed to evaluate the feasibility of adjusting significant dose levels.</p></div><div><h3>Results</h3><p><span>A total of 203 patients were included in the final analysis. Median baseline Hgb was 14.9 g/dL (interquartile range, 14.1-15.6). Patients with bone marrow HVE ≥15 Gy were found to have significantly lower predicted Hgb levels compared with those with LVE at day 90: 12.8 g/dL (95% CI, 12.4-13.3) versus 14.5 g/dL (95% CI, 14.0-14.9), respectively (</span><em>P</em> < .05). When normalizing starting Hgb levels, HVE patients still had significantly lower predicted Hgb levels than LVE at day 90: 86.1% (95% CI, 83.2%-89.7%) versus 96.2% (95% CI, 92.4%-100%), respectively. Reoptimizing 20 plans with high volume of bone marrow receiving 15 Gy resulted in a mean reduction from 1422 cc to 997 cc without compromise of other organs at risk or target coverage.</p></div><div><h3>Conclusions</h3><p>Patients with >1000 cc of bone marrow receiving ≥15 Gy had significantly lower predicted Hgb levels than those with ≤1000 cc. Reoptimization of plans demonstrated that this dose constraint is achievable without impairing plan quality. This dose constraint can be considered to limit acute marrow toxicity in patients with PC.</p></div>","PeriodicalId":14215,"journal":{"name":"International Journal of Radiation Oncology Biology Physics","volume":"118 1","pages":"Pages 85-93"},"PeriodicalIF":7.4000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Radiation Oncology Biology Physics","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0360301623077246","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/8/4 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"ONCOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose
The aim of this work was to investigate the correlation between dose to pelvic bone marrow and anemia when treating prostate cancer (PC) with definitive radiation.
Methods and Materials
Patients were selected from a prospective institutional database of patients with PC treated between 2008 and 2021. Pelvic bone (L3/L4 interface through ischial tuberosities) was contoured, and the dose to this structure was calculated. Doses were converted to 2-Gy equivalent doses using an α/β of 10. Exploratory analysis suggested dichotomizing into low-volume exposures of ≤1000 cc (LVE) and high-volume exposures of >1000 cc (HVE). Nonparametric kernel regressions were performed evaluating the effects of time, dose, and androgen deprivation therapy use on hemoglobin (Hgb) values. Reoptimization of plans was performed to evaluate the feasibility of adjusting significant dose levels.
Results
A total of 203 patients were included in the final analysis. Median baseline Hgb was 14.9 g/dL (interquartile range, 14.1-15.6). Patients with bone marrow HVE ≥15 Gy were found to have significantly lower predicted Hgb levels compared with those with LVE at day 90: 12.8 g/dL (95% CI, 12.4-13.3) versus 14.5 g/dL (95% CI, 14.0-14.9), respectively (P < .05). When normalizing starting Hgb levels, HVE patients still had significantly lower predicted Hgb levels than LVE at day 90: 86.1% (95% CI, 83.2%-89.7%) versus 96.2% (95% CI, 92.4%-100%), respectively. Reoptimizing 20 plans with high volume of bone marrow receiving 15 Gy resulted in a mean reduction from 1422 cc to 997 cc without compromise of other organs at risk or target coverage.
Conclusions
Patients with >1000 cc of bone marrow receiving ≥15 Gy had significantly lower predicted Hgb levels than those with ≤1000 cc. Reoptimization of plans demonstrated that this dose constraint is achievable without impairing plan quality. This dose constraint can be considered to limit acute marrow toxicity in patients with PC.
期刊介绍:
International Journal of Radiation Oncology • Biology • Physics (IJROBP), known in the field as the Red Journal, publishes original laboratory and clinical investigations related to radiation oncology, radiation biology, medical physics, and both education and health policy as it relates to the field.
This journal has a particular interest in original contributions of the following types: prospective clinical trials, outcomes research, and large database interrogation. In addition, it seeks reports of high-impact innovations in single or combined modality treatment, tumor sensitization, normal tissue protection (including both precision avoidance and pharmacologic means), brachytherapy, particle irradiation, and cancer imaging. Technical advances related to dosimetry and conformal radiation treatment planning are of interest, as are basic science studies investigating tumor physiology and the molecular biology underlying cancer and normal tissue radiation response.