João Moura Neto, Lais Medeiros Cardoso, Taisa Nogueira Pansani, Larissa M S C Raucci, Carlos Alberto de Souza Costa, Fernanda G Basso
{"title":"Influence of titanium and zirconia substrates on the synthesis of inflammatory mediators.","authors":"João Moura Neto, Lais Medeiros Cardoso, Taisa Nogueira Pansani, Larissa M S C Raucci, Carlos Alberto de Souza Costa, Fernanda G Basso","doi":"10.1116/6.0002659","DOIUrl":null,"url":null,"abstract":"<p><p>The repair and homeostasis of peri-implant tissues depend on several factors such as the local presence of pathogenic bacteria and their products. Among other events, peri-implant tissue response is also related to the implant material used, which interferes with cells and extracellular matrix interactions, affecting the osseointegration process. In this study, the influence of zirconia (Zr) and titanium (Ti) substrates on the response of preosteoblasts (MC3T3) and murine macrophages (RAW 264.7) exposed to lipopolysaccharide (LPS, P. gingivalis) was evaluated. Zr and Ti disks were obtained and subjected to surface roughness standardization, which was analyzed by scanning electronic microscopy (SEM). The cells were subsequently cultured on Zr and Ti surfaces in AlphaMEM culture medium for 24 h, followed by LPS stimulus for 4 h. The production of reactive oxygen species (ROS) and gene expression of inflammatory markers were determined. SEM images showed that Ti disks exhibited higher surface roughness than that of Zr disks. Cells that seeded onto Ti and Zr had increased expression of inflammatory mediators and ROS production in the presence of LPS; however, such cell responses were more evident for Ti disks. These data indicate that contact of cells with Zr surfaces may lead to a lower inflammatory potential than Ti surfaces. Elucidation of the inflammatory response triggered by LPS for cells in contact with titanium and zirconia may contribute to the selection of materials for installation of osseointegrated implants.</p>","PeriodicalId":9053,"journal":{"name":"Biointerphases","volume":"18 4","pages":""},"PeriodicalIF":1.6000,"publicationDate":"2023-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biointerphases","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1116/6.0002659","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"BIOPHYSICS","Score":null,"Total":0}
引用次数: 0
Abstract
The repair and homeostasis of peri-implant tissues depend on several factors such as the local presence of pathogenic bacteria and their products. Among other events, peri-implant tissue response is also related to the implant material used, which interferes with cells and extracellular matrix interactions, affecting the osseointegration process. In this study, the influence of zirconia (Zr) and titanium (Ti) substrates on the response of preosteoblasts (MC3T3) and murine macrophages (RAW 264.7) exposed to lipopolysaccharide (LPS, P. gingivalis) was evaluated. Zr and Ti disks were obtained and subjected to surface roughness standardization, which was analyzed by scanning electronic microscopy (SEM). The cells were subsequently cultured on Zr and Ti surfaces in AlphaMEM culture medium for 24 h, followed by LPS stimulus for 4 h. The production of reactive oxygen species (ROS) and gene expression of inflammatory markers were determined. SEM images showed that Ti disks exhibited higher surface roughness than that of Zr disks. Cells that seeded onto Ti and Zr had increased expression of inflammatory mediators and ROS production in the presence of LPS; however, such cell responses were more evident for Ti disks. These data indicate that contact of cells with Zr surfaces may lead to a lower inflammatory potential than Ti surfaces. Elucidation of the inflammatory response triggered by LPS for cells in contact with titanium and zirconia may contribute to the selection of materials for installation of osseointegrated implants.
期刊介绍:
Biointerphases emphasizes quantitative characterization of biomaterials and biological interfaces. As an interdisciplinary journal, a strong foundation of chemistry, physics, biology, engineering, theory, and/or modelling is incorporated into originated articles, reviews, and opinionated essays. In addition to regular submissions, the journal regularly features In Focus sections, targeted on specific topics and edited by experts in the field. Biointerphases is an international journal with excellence in scientific peer-review. Biointerphases is indexed in PubMed and the Science Citation Index (Clarivate Analytics). Accepted papers appear online immediately after proof processing and are uploaded to key citation sources daily. The journal is based on a mixed subscription and open-access model: Typically, authors can publish without any page charges but if the authors wish to publish open access, they can do so for a modest fee.
Topics include:
bio-surface modification
nano-bio interface
protein-surface interactions
cell-surface interactions
in vivo and in vitro systems
biofilms / biofouling
biosensors / biodiagnostics
bio on a chip
coatings
interface spectroscopy
biotribology / biorheology
molecular recognition
ambient diagnostic methods
interface modelling
adhesion phenomena.