{"title":"Management of abdominal gas leakage from surgical trocars in laparoscopic surgery: a preclinical study.","authors":"Yoshinori Hayashi, Yuji Ishii, Tomo Ishida, Kotaro Yamashita, Takuro Saito, Koji Tanaka, Kazuyoshi Yamamoto, Tomoki Makino, Tsuyoshi Takahashi, Yukinori Kurokawa, Hidetoshi Eguchi, Yuichiro Doki, Kiyokazu Nakajima","doi":"10.1080/13645706.2023.2211661","DOIUrl":null,"url":null,"abstract":"<p><p><b>Introduction:</b> There is an ongoing concern about the potential infectious risk due to pneumoperitoneal gas leakage from surgical trocars in laparoscopic surgery. We aimed to visually confirm the presence of leakage from trocars and investigate the changes in the leakage scale according to intra-abdominal pressures and trocar types. <b>Material and methods:</b> We established a porcine pneumoperitoneum model and performed experimental forceps manipulation using 5-mm grasping forceps with 12-mm trocars. The gas leakage, if any, was imaged using a Schlieren optical system, which can visualize minute gas flow invisible to the naked eye. For measuring the scale, we calculated the gas leakage velocity and area using image analysis software. Four types of unused and exhausted disposable trocars were compared. <b>Results:</b> Gas leakage was observed from trocars during forceps insertion and removal. Both the gas leakage velocity and area increased as the intra-abdominal pressure increased. Every type of trocar we handled was associated with gas leakage, and exhausted disposable trocars had the largest scale gas leakage. <b>Conclusions:</b> We confirmed gas leakage from trocars during device traffic. The scale of leakage increased with high intra-abdominal pressure and with the use of exhausted trocars. Current protection against gas leakage may not be sufficient and new surgical safety measures and device development may be needed in the future.</p>","PeriodicalId":18537,"journal":{"name":"Minimally Invasive Therapy & Allied Technologies","volume":"32 4","pages":"183-189"},"PeriodicalIF":1.7000,"publicationDate":"2023-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Minimally Invasive Therapy & Allied Technologies","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/13645706.2023.2211661","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0
Abstract
Introduction: There is an ongoing concern about the potential infectious risk due to pneumoperitoneal gas leakage from surgical trocars in laparoscopic surgery. We aimed to visually confirm the presence of leakage from trocars and investigate the changes in the leakage scale according to intra-abdominal pressures and trocar types. Material and methods: We established a porcine pneumoperitoneum model and performed experimental forceps manipulation using 5-mm grasping forceps with 12-mm trocars. The gas leakage, if any, was imaged using a Schlieren optical system, which can visualize minute gas flow invisible to the naked eye. For measuring the scale, we calculated the gas leakage velocity and area using image analysis software. Four types of unused and exhausted disposable trocars were compared. Results: Gas leakage was observed from trocars during forceps insertion and removal. Both the gas leakage velocity and area increased as the intra-abdominal pressure increased. Every type of trocar we handled was associated with gas leakage, and exhausted disposable trocars had the largest scale gas leakage. Conclusions: We confirmed gas leakage from trocars during device traffic. The scale of leakage increased with high intra-abdominal pressure and with the use of exhausted trocars. Current protection against gas leakage may not be sufficient and new surgical safety measures and device development may be needed in the future.
期刊介绍:
Minimally Invasive Therapy and Allied Technologies (MITAT) is an international forum for endoscopic surgeons, interventional radiologists and industrial instrument manufacturers. It is the official journal of the Society for Medical Innovation and Technology (SMIT) whose membership includes representatives from a broad spectrum of medical specialities, instrument manufacturing and research. The journal brings the latest developments and innovations in minimally invasive therapy to its readers. What makes Minimally Invasive Therapy and Allied Technologies unique is that we publish one or two special issues each year, which are devoted to a specific theme. Key topics covered by the journal include: interventional radiology, endoscopic surgery, imaging technology, manipulators and robotics for surgery and education and training for MIS.