{"title":"全腕关节置换术后,腕关节固定术结合大块骨异体移植治疗植入物松动:病例报告。","authors":"Yoshihisa Nasu, Keiichiro Nishida, Masamitsu Natsumeda, Ryuichi Nakahara, Ryozo Harada, Toshifumi Ozaki","doi":"10.1093/mrcr/rxad048","DOIUrl":null,"url":null,"abstract":"<p><p>Total wrist arthroplasty (TWA) is a challenging procedure for wrist joints severely destroyed by rheumatoid arthritis. The most common postoperative complication of TWAs is the loosening of the carpal component. Revision surgeries for failed TWAs can be complicated owing to severe bone loss and concomitant soft-tissue problems. Here, we report a case (68-year-old woman with a history of rheumatoid arthritis for 24 years) of severe aseptic loosening of semi-constrained TWA and its salvage surgery. During the primary arthroplasty procedure, severe instability at the second through fifth carpometacarpal joints was observed and arthrodesis of these joints was required. The radiographs obtained 9 months after surgery showed loosening of the carpal component. Subsequently, she suffered a stroke, resulting in a loss of follow-up, and higher stress was loaded on her upper extremities during standing and walking. In the radiograph taken at her revisit 25 months after the primary surgery, the subsidence of the carpal component progressed and loosening of the radial component was observed. Total wrist arthrodesis was performed using a bulk bone allograft of the femoral head, combined with a penetrating Wrist Fusion Rod®. Rapid bone union was achieved without soft-tissue irritation. We conclude that wrist arthrodesis with a bulk bone allograft combined with an intramedullary nail is a reasonable option for failed total wrist arthroplasty.</p>","PeriodicalId":18677,"journal":{"name":"Modern Rheumatology Case Reports","volume":" ","pages":"43-48"},"PeriodicalIF":0.0000,"publicationDate":"2023-12-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Wrist arthrodesis combined with a bulk bone allograft for implant loosening after total wrist arthroplasty: A case report.\",\"authors\":\"Yoshihisa Nasu, Keiichiro Nishida, Masamitsu Natsumeda, Ryuichi Nakahara, Ryozo Harada, Toshifumi Ozaki\",\"doi\":\"10.1093/mrcr/rxad048\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Total wrist arthroplasty (TWA) is a challenging procedure for wrist joints severely destroyed by rheumatoid arthritis. The most common postoperative complication of TWAs is the loosening of the carpal component. Revision surgeries for failed TWAs can be complicated owing to severe bone loss and concomitant soft-tissue problems. Here, we report a case (68-year-old woman with a history of rheumatoid arthritis for 24 years) of severe aseptic loosening of semi-constrained TWA and its salvage surgery. During the primary arthroplasty procedure, severe instability at the second through fifth carpometacarpal joints was observed and arthrodesis of these joints was required. The radiographs obtained 9 months after surgery showed loosening of the carpal component. Subsequently, she suffered a stroke, resulting in a loss of follow-up, and higher stress was loaded on her upper extremities during standing and walking. In the radiograph taken at her revisit 25 months after the primary surgery, the subsidence of the carpal component progressed and loosening of the radial component was observed. Total wrist arthrodesis was performed using a bulk bone allograft of the femoral head, combined with a penetrating Wrist Fusion Rod®. Rapid bone union was achieved without soft-tissue irritation. We conclude that wrist arthrodesis with a bulk bone allograft combined with an intramedullary nail is a reasonable option for failed total wrist arthroplasty.</p>\",\"PeriodicalId\":18677,\"journal\":{\"name\":\"Modern Rheumatology Case Reports\",\"volume\":\" \",\"pages\":\"43-48\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-12-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Modern Rheumatology Case Reports\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1093/mrcr/rxad048\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Modern Rheumatology Case Reports","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/mrcr/rxad048","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
全腕关节置换术(TWA)是一种治疗因类风湿性关节炎而严重受损的腕关节的高难度手术。TWA 最常见的术后并发症是腕关节组件松动。由于严重的骨质流失和伴随的软组织问题,TWA失败后的翻修手术可能很复杂。在此,我们报告了一例(68 岁女性,类风湿性关节炎病史 24 年)半约束 TWA 的严重无菌性松动及其挽救手术。在初次关节置换术中,观察到第二至第五腕掌关节严重失稳,因此需要对这些关节进行关节固定。术后 9 个月的 X 光片显示腕关节组件出现松动。随后,她因中风而失去了随访机会,站立和行走时上肢承受了更大的压力。在初次手术后 25 个月复查时拍摄的照片中,她的腕关节组件下沉,桡骨组件也出现了松动。我们使用股骨头大块骨异体移植,结合穿透式腕关节融合棒®,对她进行了全腕关节置换术。在没有软组织刺激的情况下实现了快速骨结合。我们的结论是,使用大块骨异体移植结合髓内钉进行腕关节置换术是治疗失败的全腕关节置换术的合理选择。
Wrist arthrodesis combined with a bulk bone allograft for implant loosening after total wrist arthroplasty: A case report.
Total wrist arthroplasty (TWA) is a challenging procedure for wrist joints severely destroyed by rheumatoid arthritis. The most common postoperative complication of TWAs is the loosening of the carpal component. Revision surgeries for failed TWAs can be complicated owing to severe bone loss and concomitant soft-tissue problems. Here, we report a case (68-year-old woman with a history of rheumatoid arthritis for 24 years) of severe aseptic loosening of semi-constrained TWA and its salvage surgery. During the primary arthroplasty procedure, severe instability at the second through fifth carpometacarpal joints was observed and arthrodesis of these joints was required. The radiographs obtained 9 months after surgery showed loosening of the carpal component. Subsequently, she suffered a stroke, resulting in a loss of follow-up, and higher stress was loaded on her upper extremities during standing and walking. In the radiograph taken at her revisit 25 months after the primary surgery, the subsidence of the carpal component progressed and loosening of the radial component was observed. Total wrist arthrodesis was performed using a bulk bone allograft of the femoral head, combined with a penetrating Wrist Fusion Rod®. Rapid bone union was achieved without soft-tissue irritation. We conclude that wrist arthrodesis with a bulk bone allograft combined with an intramedullary nail is a reasonable option for failed total wrist arthroplasty.