分析测定和引导重采样法验证罗氏 Elecsys STAT 高灵敏肌钙蛋白 T 测定的性能及其在 ESC NTSTEMI 指南 "排除 "部分的应用。

IF 2.1 4区 医学 Q3 MEDICAL LABORATORY TECHNOLOGY
Annals of Clinical Biochemistry Pub Date : 2024-01-01 Epub Date: 2023-08-07 DOI:10.1177/00045632231194449
David Metsu, Daphné Mille, Carole Pailly, Valerica G Oancea, Luc Essemilaire, Dominique Coppin
{"title":"分析测定和引导重采样法验证罗氏 Elecsys STAT 高灵敏肌钙蛋白 T 测定的性能及其在 ESC NTSTEMI 指南 \"排除 \"部分的应用。","authors":"David Metsu, Daphné Mille, Carole Pailly, Valerica G Oancea, Luc Essemilaire, Dominique Coppin","doi":"10.1177/00045632231194449","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The European Society of Cardiology (ESC) guidelines recommend a dynamic (0-1h) cardiac troponin (cTn) determination for non-ST elevation myocardial infarction diagnosis. For patients with low cTn levels, a discharge from emergency can be considered. Nevertheless, cTn cutoffs for discharge are lower than the limits of quantification proposed by laboratory reagent suppliers.</p><p><strong>Aim: </strong>Validate cTn assay on the Elecsys STAT kit.</p><p><strong>Materials and methods: </strong>Precision, trueness, repeatability and within-laboratory variability were calculated from internal quality control and plasma pooled at 5.78 and 10.73 ng/L. Accuracy was calculated from external quality control. Uncertainty of measurement was calculated from (i) the uncertainty of the standard and control values and (ii) by precision from pooled plasma. Distribution of precision results from pooled plasma has been evaluated by bootstrap simulations. Dilution linearity tests with patient plasma were performed to evaluate the method for values near 5 ng/L.</p><p><strong>Results: </strong>Precision and trueness ranged from 1.35 to 4.45% and from 0.14 to -3.74%, respectively. Accuracy results ranged from 101.40 to 104.90%. Within laboratory variability was 2.91%. Uncertainty ranged from 3.66% to 19.90% for higher (2188) to lower values (5.78 ng/L). Bootstrap simulations allowed utilization of precision data from pooled plasma to evaluate cTn assay. The method was linear from 4.48 to 39.80 ng/L. A linear regression model best described the data.</p><p><strong>Conclusion: </strong>Elecsys STAT method provides accurate cTn results, including patients with cTn results categorizing them as 'rule-out' in the ESC guidelines.</p>","PeriodicalId":8005,"journal":{"name":"Annals of Clinical Biochemistry","volume":" ","pages":"63-69"},"PeriodicalIF":2.1000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Analytical assays and bootstrap resampling method to validate performance of the Roche Elecsys STAT highly sensitive troponin T assay and its application for the 'rule-out' part of ESC guidelines for NTSTEMI.\",\"authors\":\"David Metsu, Daphné Mille, Carole Pailly, Valerica G Oancea, Luc Essemilaire, Dominique Coppin\",\"doi\":\"10.1177/00045632231194449\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>The European Society of Cardiology (ESC) guidelines recommend a dynamic (0-1h) cardiac troponin (cTn) determination for non-ST elevation myocardial infarction diagnosis. For patients with low cTn levels, a discharge from emergency can be considered. Nevertheless, cTn cutoffs for discharge are lower than the limits of quantification proposed by laboratory reagent suppliers.</p><p><strong>Aim: </strong>Validate cTn assay on the Elecsys STAT kit.</p><p><strong>Materials and methods: </strong>Precision, trueness, repeatability and within-laboratory variability were calculated from internal quality control and plasma pooled at 5.78 and 10.73 ng/L. Accuracy was calculated from external quality control. Uncertainty of measurement was calculated from (i) the uncertainty of the standard and control values and (ii) by precision from pooled plasma. Distribution of precision results from pooled plasma has been evaluated by bootstrap simulations. Dilution linearity tests with patient plasma were performed to evaluate the method for values near 5 ng/L.</p><p><strong>Results: </strong>Precision and trueness ranged from 1.35 to 4.45% and from 0.14 to -3.74%, respectively. Accuracy results ranged from 101.40 to 104.90%. Within laboratory variability was 2.91%. Uncertainty ranged from 3.66% to 19.90% for higher (2188) to lower values (5.78 ng/L). Bootstrap simulations allowed utilization of precision data from pooled plasma to evaluate cTn assay. The method was linear from 4.48 to 39.80 ng/L. A linear regression model best described the data.</p><p><strong>Conclusion: </strong>Elecsys STAT method provides accurate cTn results, including patients with cTn results categorizing them as 'rule-out' in the ESC guidelines.</p>\",\"PeriodicalId\":8005,\"journal\":{\"name\":\"Annals of Clinical Biochemistry\",\"volume\":\" \",\"pages\":\"63-69\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Annals of Clinical Biochemistry\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/00045632231194449\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/8/7 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"MEDICAL LABORATORY TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of Clinical Biochemistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/00045632231194449","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/8/7 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

背景:欧洲心脏病学会(ESC)指南建议采用动态(0-1 小时)心肌肌钙蛋白(cTn)测定来诊断非 ST 段抬高型心肌梗死。对于 cTn 水平较低的患者,可以考虑急诊出院。然而,出院的 cTn 临界值低于实验室试剂供应商建议的定量限:根据内部质控和 5.78 和 10.73 纳克/升的血浆池计算精确度、真实度、可重复性和实验室内变异性。准确度由外部质量控制计算得出。测量的不确定性根据(i)标准值和对照值的不确定性以及(ii)血浆池的精密度计算得出。通过自举模拟评估了集合血浆精确度结果的分布情况。用患者血浆进行稀释线性测试,以评估接近 5 纳克/升值的方法:结果:精确度和真实度范围分别为 1.35% 至 4.45% 和 0.14% 至 -3.74%。准确度为 101.40% 至 104.90%。实验室内变异率为 2.91%。从较高值(2188)到较低值(5.78 纳克/升),不确定性在 3.66% 到 19.90% 之间。通过 Bootstrap 模拟,可以利用来自集合血浆的精确数据来评估 cTn 检测。该方法在 4.48 至 39.80 纳克/升之间呈线性关系。线性回归模型对数据进行了最佳描述:Elecsys STAT 方法可提供准确的 cTn 结果,包括在 ESC 指南中将 cTn 结果归类为 "排除 "的患者。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Analytical assays and bootstrap resampling method to validate performance of the Roche Elecsys STAT highly sensitive troponin T assay and its application for the 'rule-out' part of ESC guidelines for NTSTEMI.

Background: The European Society of Cardiology (ESC) guidelines recommend a dynamic (0-1h) cardiac troponin (cTn) determination for non-ST elevation myocardial infarction diagnosis. For patients with low cTn levels, a discharge from emergency can be considered. Nevertheless, cTn cutoffs for discharge are lower than the limits of quantification proposed by laboratory reagent suppliers.

Aim: Validate cTn assay on the Elecsys STAT kit.

Materials and methods: Precision, trueness, repeatability and within-laboratory variability were calculated from internal quality control and plasma pooled at 5.78 and 10.73 ng/L. Accuracy was calculated from external quality control. Uncertainty of measurement was calculated from (i) the uncertainty of the standard and control values and (ii) by precision from pooled plasma. Distribution of precision results from pooled plasma has been evaluated by bootstrap simulations. Dilution linearity tests with patient plasma were performed to evaluate the method for values near 5 ng/L.

Results: Precision and trueness ranged from 1.35 to 4.45% and from 0.14 to -3.74%, respectively. Accuracy results ranged from 101.40 to 104.90%. Within laboratory variability was 2.91%. Uncertainty ranged from 3.66% to 19.90% for higher (2188) to lower values (5.78 ng/L). Bootstrap simulations allowed utilization of precision data from pooled plasma to evaluate cTn assay. The method was linear from 4.48 to 39.80 ng/L. A linear regression model best described the data.

Conclusion: Elecsys STAT method provides accurate cTn results, including patients with cTn results categorizing them as 'rule-out' in the ESC guidelines.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Annals of Clinical Biochemistry
Annals of Clinical Biochemistry Biochemistry, Genetics and Molecular Biology-Clinical Biochemistry
CiteScore
5.20
自引率
4.50%
发文量
61
期刊介绍: Annals of Clinical Biochemistry is the fully peer reviewed international journal of the Association for Clinical Biochemistry and Laboratory Medicine. Annals of Clinical Biochemistry accepts papers that contribute to knowledge in all fields of laboratory medicine, especially those pertaining to the understanding, diagnosis and treatment of human disease. It publishes papers on clinical biochemistry, clinical audit, metabolic medicine, immunology, genetics, biotechnology, haematology, microbiology, computing and management where they have both biochemical and clinical relevance. Papers describing evaluation or implementation of commercial reagent kits or the performance of new analysers require substantial original information. Unless of exceptional interest and novelty, studies dealing with the redox status in various diseases are not generally considered within the journal''s scope. Studies documenting the association of single nucleotide polymorphisms (SNPs) with particular phenotypes will not normally be considered, given the greater strength of genome wide association studies (GWAS). Research undertaken in non-human animals will not be considered for publication in the Annals. Annals of Clinical Biochemistry is also the official journal of NVKC (de Nederlandse Vereniging voor Klinische Chemie) and JSCC (Japan Society of Clinical Chemistry).
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信