KangarooSci®好氧计数板在选定食品和不锈钢环境表面中嗜氧需氧细菌计数的验证:AOAC性能测试方法sm 062301。

IF 1.7 4区 农林科学 Q3 CHEMISTRY, ANALYTICAL
Danping Wei, Di Wu, Jisheng Wang, Yazhou Li, Xinyu Sun, Can Zhang, Shuai Zhang, Wesley Thompson, M Joseph Benzinger, Erin Crowley
{"title":"KangarooSci®好氧计数板在选定食品和不锈钢环境表面中嗜氧需氧细菌计数的验证:AOAC性能测试方法sm 062301。","authors":"Danping Wei,&nbsp;Di Wu,&nbsp;Jisheng Wang,&nbsp;Yazhou Li,&nbsp;Xinyu Sun,&nbsp;Can Zhang,&nbsp;Shuai Zhang,&nbsp;Wesley Thompson,&nbsp;M Joseph Benzinger,&nbsp;Erin Crowley","doi":"10.1093/jaoacint/qsad088","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The KangarooSci® Aerobic Count Plate (ACP) is a sample-ready culture medium system for direct counting of aerobic bacteria colonies after 48-72 h of incubation.</p><p><strong>Objective: </strong>The KangarooSci ACP was evaluated for AOAC Performance Tested MethodsSM certification.</p><p><strong>Methods: </strong>The KangarooSci ACP was evaluated through matrix studies and product consistency/stability study and robustness testing. For the matrix study, nine food products (nonfat dry milk powder, fresh raw bovine milk, pasteurized liquid bovine milk, fresh raw ground beef, frozen uncooked chicken breast, cooked shredded pork, apple juice, ice cream, and fresh strawberries), and one environmental surface (stainless steel) were evaluated following the KangarooSci ACP product instructions and compared to the ISO 4833-1:2013, Microbiology of food and animal feeding stuffs-Horizontal methods for the enumeration of microorganisms-Part 1: Colony count at 30 °C by the pour plate technique reference standard. The product consistency and stability testing evaluated three separate production lots of the KangarooSci ACP. The robustness testing examined three test parameters, volume of sample plated, incubation time, and incubation temperature, using a factorial study design.</p><p><strong>Results: </strong>Results from the matrix study demonstrated equivalent performance between the KangarooSci ACP and the ISO 4833-1:2013 reference standard. The product consistency and stability testing showed that the performance of the assay was equivalent over time up to 12 months and between production lots. Minor changes to the operational test conditions showed no significant impact on performance during the robustness testing.</p><p><strong>Conclusion: </strong>The KangarooSci ACP is an effective method for aerobic plate count for all matrixes evaluated.</p><p><strong>Highlights: </strong>The KangarooSci ACP allows for fast, reliable enumeration of aerobic bacteria. Utilizing the alternative method takes up less space in incubators, requires no sample spreader, and requires fewer consumables compared to the reference method.</p>","PeriodicalId":15003,"journal":{"name":"Journal of AOAC International","volume":" ","pages":"1589-1597"},"PeriodicalIF":1.7000,"publicationDate":"2023-11-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Validation of the KangarooSci® Aerobic Count Plate for the Enumeration of Meosphilic Aerobic Bacteria in Selected Foods and on Stainless Steel Environmental Surfaces: AOAC Performance Tested MethodSM 062301.\",\"authors\":\"Danping Wei,&nbsp;Di Wu,&nbsp;Jisheng Wang,&nbsp;Yazhou Li,&nbsp;Xinyu Sun,&nbsp;Can Zhang,&nbsp;Shuai Zhang,&nbsp;Wesley Thompson,&nbsp;M Joseph Benzinger,&nbsp;Erin Crowley\",\"doi\":\"10.1093/jaoacint/qsad088\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>The KangarooSci® Aerobic Count Plate (ACP) is a sample-ready culture medium system for direct counting of aerobic bacteria colonies after 48-72 h of incubation.</p><p><strong>Objective: </strong>The KangarooSci ACP was evaluated for AOAC Performance Tested MethodsSM certification.</p><p><strong>Methods: </strong>The KangarooSci ACP was evaluated through matrix studies and product consistency/stability study and robustness testing. For the matrix study, nine food products (nonfat dry milk powder, fresh raw bovine milk, pasteurized liquid bovine milk, fresh raw ground beef, frozen uncooked chicken breast, cooked shredded pork, apple juice, ice cream, and fresh strawberries), and one environmental surface (stainless steel) were evaluated following the KangarooSci ACP product instructions and compared to the ISO 4833-1:2013, Microbiology of food and animal feeding stuffs-Horizontal methods for the enumeration of microorganisms-Part 1: Colony count at 30 °C by the pour plate technique reference standard. The product consistency and stability testing evaluated three separate production lots of the KangarooSci ACP. The robustness testing examined three test parameters, volume of sample plated, incubation time, and incubation temperature, using a factorial study design.</p><p><strong>Results: </strong>Results from the matrix study demonstrated equivalent performance between the KangarooSci ACP and the ISO 4833-1:2013 reference standard. The product consistency and stability testing showed that the performance of the assay was equivalent over time up to 12 months and between production lots. Minor changes to the operational test conditions showed no significant impact on performance during the robustness testing.</p><p><strong>Conclusion: </strong>The KangarooSci ACP is an effective method for aerobic plate count for all matrixes evaluated.</p><p><strong>Highlights: </strong>The KangarooSci ACP allows for fast, reliable enumeration of aerobic bacteria. Utilizing the alternative method takes up less space in incubators, requires no sample spreader, and requires fewer consumables compared to the reference method.</p>\",\"PeriodicalId\":15003,\"journal\":{\"name\":\"Journal of AOAC International\",\"volume\":\" \",\"pages\":\"1589-1597\"},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2023-11-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of AOAC International\",\"FirstCategoryId\":\"97\",\"ListUrlMain\":\"https://doi.org/10.1093/jaoacint/qsad088\",\"RegionNum\":4,\"RegionCategory\":\"农林科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of AOAC International","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.1093/jaoacint/qsad088","RegionNum":4,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

背景:KangaroSci®需氧菌计数板(ACP)是一种可直接计数48-72后需氧菌菌落的样品培养基系统 孵育h。目的:对KangaroSci-ACP进行AOAC性能测试方法SM认证。方法:通过基质研究、产品一致性/稳定性研究和稳健性测试对KangaroSci-ACP进行评估。在基质研究中,九种食品(脱脂奶粉、新鲜生牛乳、巴氏灭菌液态牛乳、新鲜生碎牛肉、冷冻生鸡胸肉、熟肉丝、苹果汁、冰淇淋和新鲜草莓)和一种环境表面(不锈钢)按照KangaroSci-ACP产品说明进行了评估,并与ISO 4833-1:2013进行了比较,食品和动物饲料的微生物学微生物计数的水平方法第1部分:30时的菌落计数 °C,采用浇注板技术参考标准。产品一致性和稳定性测试评估了KangaroSci-ACP的三个独立生产批次。稳健性测试使用析因研究设计检查了三个测试参数,即样品电镀体积、培养时间和培养温度。结果:基质研究的结果表明,KangaroSci-ACP和ISO 4833-1:2013参考标准的性能相当。产品一致性和稳定性测试表明,在长达12 月和生产批次之间。在稳健性测试期间,操作测试条件的微小变化对性能没有显著影响。结论:KangaroSci-ACP是一种对所有基质进行有氧平板计数的有效方法。亮点:袋鼠科学ACP允许快速、可靠地计数需氧细菌。与参考方法相比,使用替代方法在培养箱中占用更少的空间,不需要样品散布器,并且需要更少的耗材。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Validation of the KangarooSci® Aerobic Count Plate for the Enumeration of Meosphilic Aerobic Bacteria in Selected Foods and on Stainless Steel Environmental Surfaces: AOAC Performance Tested MethodSM 062301.

Background: The KangarooSci® Aerobic Count Plate (ACP) is a sample-ready culture medium system for direct counting of aerobic bacteria colonies after 48-72 h of incubation.

Objective: The KangarooSci ACP was evaluated for AOAC Performance Tested MethodsSM certification.

Methods: The KangarooSci ACP was evaluated through matrix studies and product consistency/stability study and robustness testing. For the matrix study, nine food products (nonfat dry milk powder, fresh raw bovine milk, pasteurized liquid bovine milk, fresh raw ground beef, frozen uncooked chicken breast, cooked shredded pork, apple juice, ice cream, and fresh strawberries), and one environmental surface (stainless steel) were evaluated following the KangarooSci ACP product instructions and compared to the ISO 4833-1:2013, Microbiology of food and animal feeding stuffs-Horizontal methods for the enumeration of microorganisms-Part 1: Colony count at 30 °C by the pour plate technique reference standard. The product consistency and stability testing evaluated three separate production lots of the KangarooSci ACP. The robustness testing examined three test parameters, volume of sample plated, incubation time, and incubation temperature, using a factorial study design.

Results: Results from the matrix study demonstrated equivalent performance between the KangarooSci ACP and the ISO 4833-1:2013 reference standard. The product consistency and stability testing showed that the performance of the assay was equivalent over time up to 12 months and between production lots. Minor changes to the operational test conditions showed no significant impact on performance during the robustness testing.

Conclusion: The KangarooSci ACP is an effective method for aerobic plate count for all matrixes evaluated.

Highlights: The KangarooSci ACP allows for fast, reliable enumeration of aerobic bacteria. Utilizing the alternative method takes up less space in incubators, requires no sample spreader, and requires fewer consumables compared to the reference method.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of AOAC International
Journal of AOAC International 医学-分析化学
CiteScore
3.10
自引率
12.50%
发文量
144
审稿时长
2.7 months
期刊介绍: The Journal of AOAC INTERNATIONAL publishes the latest in basic and applied research in analytical sciences related to foods, drugs, agriculture, the environment, and more. The Journal is the method researchers'' forum for exchanging information and keeping informed of new technology and techniques pertinent to regulatory agencies and regulated industries.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信