用球囊导管解结血管造影导管1例。

Motonori Takahagi, Haruyuki Takaki, Hiroyuki Yokoyama, Junichi Taniguchi, Hisashi Komoto, Atsushi Ogasawara, Hiroshi Kodama, Yasukazu Kako, Kaoru Kobayashi, Koichiro Yamakado
{"title":"用球囊导管解结血管造影导管1例。","authors":"Motonori Takahagi,&nbsp;Haruyuki Takaki,&nbsp;Hiroyuki Yokoyama,&nbsp;Junichi Taniguchi,&nbsp;Hisashi Komoto,&nbsp;Atsushi Ogasawara,&nbsp;Hiroshi Kodama,&nbsp;Yasukazu Kako,&nbsp;Kaoru Kobayashi,&nbsp;Koichiro Yamakado","doi":"10.22575/interventionalradiology.2022-0036","DOIUrl":null,"url":null,"abstract":"<p><p>When a 66-year-old man with hepatocellular carcinoma underwent an angiographic examination, a 4-Fr catheter was inserted from the right femoral artery. It became tightly knotted in the descending aorta. To untangle the knotted catheter, a noncompliant balloon catheter was delivered into the knotted loop from the contralateral femoral artery. After the balloon catheter was inflated from the inside of the knotted loop, the knot became loose. Finally, the knotted catheter was untangled. Subsequently, the remainder of the examination was performed as initially planned.</p>","PeriodicalId":73503,"journal":{"name":"Interventional radiology (Higashimatsuyama-shi (Japan)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/2c/62/2432-0935-8-2-0080.PMC10359165.pdf","citationCount":"1","resultStr":"{\"title\":\"Untangling a Knotted Angiographic Catheter Using a Balloon Catheter: A Case Report.\",\"authors\":\"Motonori Takahagi,&nbsp;Haruyuki Takaki,&nbsp;Hiroyuki Yokoyama,&nbsp;Junichi Taniguchi,&nbsp;Hisashi Komoto,&nbsp;Atsushi Ogasawara,&nbsp;Hiroshi Kodama,&nbsp;Yasukazu Kako,&nbsp;Kaoru Kobayashi,&nbsp;Koichiro Yamakado\",\"doi\":\"10.22575/interventionalradiology.2022-0036\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>When a 66-year-old man with hepatocellular carcinoma underwent an angiographic examination, a 4-Fr catheter was inserted from the right femoral artery. It became tightly knotted in the descending aorta. To untangle the knotted catheter, a noncompliant balloon catheter was delivered into the knotted loop from the contralateral femoral artery. After the balloon catheter was inflated from the inside of the knotted loop, the knot became loose. Finally, the knotted catheter was untangled. Subsequently, the remainder of the examination was performed as initially planned.</p>\",\"PeriodicalId\":73503,\"journal\":{\"name\":\"Interventional radiology (Higashimatsuyama-shi (Japan)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/2c/62/2432-0935-8-2-0080.PMC10359165.pdf\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Interventional radiology (Higashimatsuyama-shi (Japan)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.22575/interventionalradiology.2022-0036\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Interventional radiology (Higashimatsuyama-shi (Japan)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22575/interventionalradiology.2022-0036","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

当一名66岁的肝癌患者接受血管造影检查时,从右股动脉插入一根4-Fr导管。它在降主动脉上紧紧地打结了。为了解开打结的导管,从对侧股动脉将一根不合规的球囊导管送入打结的袢。当气球导管从打结的环内充气后,结变松了。最后,解开打结的导管。随后,剩余的检查工作按原计划进行。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Untangling a Knotted Angiographic Catheter Using a Balloon Catheter: A Case Report.

Untangling a Knotted Angiographic Catheter Using a Balloon Catheter: A Case Report.

Untangling a Knotted Angiographic Catheter Using a Balloon Catheter: A Case Report.

Untangling a Knotted Angiographic Catheter Using a Balloon Catheter: A Case Report.

When a 66-year-old man with hepatocellular carcinoma underwent an angiographic examination, a 4-Fr catheter was inserted from the right femoral artery. It became tightly knotted in the descending aorta. To untangle the knotted catheter, a noncompliant balloon catheter was delivered into the knotted loop from the contralateral femoral artery. After the balloon catheter was inflated from the inside of the knotted loop, the knot became loose. Finally, the knotted catheter was untangled. Subsequently, the remainder of the examination was performed as initially planned.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信