{"title":"对于大的局灶性肝脏病变,超声造影的替代性第二表现对于充分表征是必要的。","authors":"Yang Wang, Size Wu","doi":"10.3233/CH-231721","DOIUrl":null,"url":null,"abstract":"<p><p>Focal liver lesions (FFLs) evaluated using contrast-enhanced ultrasound (CEUS) and contrast-enhanced computed tomography (CECT) may have the same or similar findings or substantial discrepant findings. Such phenomenon can be found in two performances of CEUS that the second performance of CEUS conducted shortly following the initial performance of CEUS. Discrepancy of two performances of CEUS for FFLs occurring in the same patient at a short internal has not been well addressed, which raises challenge for CEUS for the evaluation of FFLs. In this case study, such phenomenon is illustrated and implication is obtained.</p>","PeriodicalId":10425,"journal":{"name":"Clinical hemorheology and microcirculation","volume":"84 2","pages":"177-184"},"PeriodicalIF":2.1000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"An alternative second performance of contrast-enhanced ultrasound for large focal liver lesion is necessary for sufficient characterization.\",\"authors\":\"Yang Wang, Size Wu\",\"doi\":\"10.3233/CH-231721\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Focal liver lesions (FFLs) evaluated using contrast-enhanced ultrasound (CEUS) and contrast-enhanced computed tomography (CECT) may have the same or similar findings or substantial discrepant findings. Such phenomenon can be found in two performances of CEUS that the second performance of CEUS conducted shortly following the initial performance of CEUS. Discrepancy of two performances of CEUS for FFLs occurring in the same patient at a short internal has not been well addressed, which raises challenge for CEUS for the evaluation of FFLs. In this case study, such phenomenon is illustrated and implication is obtained.</p>\",\"PeriodicalId\":10425,\"journal\":{\"name\":\"Clinical hemorheology and microcirculation\",\"volume\":\"84 2\",\"pages\":\"177-184\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical hemorheology and microcirculation\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3233/CH-231721\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"HEMATOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical hemorheology and microcirculation","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3233/CH-231721","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"HEMATOLOGY","Score":null,"Total":0}
An alternative second performance of contrast-enhanced ultrasound for large focal liver lesion is necessary for sufficient characterization.
Focal liver lesions (FFLs) evaluated using contrast-enhanced ultrasound (CEUS) and contrast-enhanced computed tomography (CECT) may have the same or similar findings or substantial discrepant findings. Such phenomenon can be found in two performances of CEUS that the second performance of CEUS conducted shortly following the initial performance of CEUS. Discrepancy of two performances of CEUS for FFLs occurring in the same patient at a short internal has not been well addressed, which raises challenge for CEUS for the evaluation of FFLs. In this case study, such phenomenon is illustrated and implication is obtained.
期刊介绍:
Clinical Hemorheology and Microcirculation, a peer-reviewed international scientific journal, serves as an aid to understanding the flow properties of blood and the relationship to normal and abnormal physiology. The rapidly expanding science of hemorheology concerns blood, its components and the blood vessels with which blood interacts. It includes perihemorheology, i.e., the rheology of fluid and structures in the perivascular and interstitial spaces as well as the lymphatic system. The clinical aspects include pathogenesis, symptomatology and diagnostic methods, and the fields of prophylaxis and therapy in all branches of medicine and surgery, pharmacology and drug research.
The endeavour of the Editors-in-Chief and publishers of Clinical Hemorheology and Microcirculation is to bring together contributions from those working in various fields related to blood flow all over the world. The editors of Clinical Hemorheology and Microcirculation are from those countries in Europe, Asia, Australia and America where appreciable work in clinical hemorheology and microcirculation is being carried out. Each editor takes responsibility to decide on the acceptance of a manuscript. He is required to have the manuscript appraised by two referees and may be one of them himself. The executive editorial office, to which the manuscripts have been submitted, is responsible for rapid handling of the reviewing process.
Clinical Hemorheology and Microcirculation accepts original papers, brief communications, mini-reports and letters to the Editors-in-Chief. Review articles, providing general views and new insights into related subjects, are regularly invited by the Editors-in-Chief. Proceedings of international and national conferences on clinical hemorheology (in original form or as abstracts) complete the range of editorial features.