{"title":"预测早产儿是否需要表面活性疗法的生化和肺功能测试准确性:系统回顾","authors":"Anna Lavizzari, Chiara Veneroni","doi":"10.1159/000527670","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>We evaluate the accuracy of postnatal biochemical and lung function tests performed within 3 h from birth for predicting surfactant need in preterm infants ≤34 weeks' gestation receiving noninvasive respiratory support for respiratory distress syndrome (RDS).</p><p><strong>Methods: </strong>We systematically searched MEDLINE, Embase, The Cochrane Library, PROSPERO, and clinicaltrials.gov databases for studies published from 2000 to November 10, 2021, cross-referencing relevant literature and contacting experts. We included diagnostic accuracy studies and systematic reviews of biochemical or lung function tests identifying the need for surfactant in preterm neonates ≤34 weeks' with RDS not intubated at birth. The authors individually assessed the risk of bias following a tailored QUADAS-2 tool.</p><p><strong>Results: </strong>Eight studies, including 810 infants, met the inclusion criteria. Four tests were included: the click test, the stable microbubble test, the lamellar body count on gastric aspirates, and the forced oscillation technique. The reference standards were transparent criteria for distinguishing the infants according to oxygen requirement, which reflected the current criteria for surfactant therapy. The risk of bias was judged high because of the population selection and exclusion of participants from the analysis. There were no serious concerns regarding blinding and applicability. The individual study sensitivity and specificity range from 0.60 to 1 and from 0.51 to 0.91, respectively. It was not appropriate to combine the accuracy estimates in a meta-analysis because of the heterogeneity of the study characteristics.</p><p><strong>Conclusions: </strong>Current evidence is insufficient to recommend biochemical and lung function tests for tailoring surfactant therapy.</p>","PeriodicalId":18924,"journal":{"name":"Neonatology","volume":"120 3","pages":"275-286"},"PeriodicalIF":2.6000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Biochemical and Lung Function Test Accuracy for Predicting the Need for Surfactant Therapy in Preterm Infants: A Systematic Review.\",\"authors\":\"Anna Lavizzari, Chiara Veneroni\",\"doi\":\"10.1159/000527670\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>We evaluate the accuracy of postnatal biochemical and lung function tests performed within 3 h from birth for predicting surfactant need in preterm infants ≤34 weeks' gestation receiving noninvasive respiratory support for respiratory distress syndrome (RDS).</p><p><strong>Methods: </strong>We systematically searched MEDLINE, Embase, The Cochrane Library, PROSPERO, and clinicaltrials.gov databases for studies published from 2000 to November 10, 2021, cross-referencing relevant literature and contacting experts. We included diagnostic accuracy studies and systematic reviews of biochemical or lung function tests identifying the need for surfactant in preterm neonates ≤34 weeks' with RDS not intubated at birth. The authors individually assessed the risk of bias following a tailored QUADAS-2 tool.</p><p><strong>Results: </strong>Eight studies, including 810 infants, met the inclusion criteria. Four tests were included: the click test, the stable microbubble test, the lamellar body count on gastric aspirates, and the forced oscillation technique. The reference standards were transparent criteria for distinguishing the infants according to oxygen requirement, which reflected the current criteria for surfactant therapy. The risk of bias was judged high because of the population selection and exclusion of participants from the analysis. There were no serious concerns regarding blinding and applicability. The individual study sensitivity and specificity range from 0.60 to 1 and from 0.51 to 0.91, respectively. It was not appropriate to combine the accuracy estimates in a meta-analysis because of the heterogeneity of the study characteristics.</p><p><strong>Conclusions: </strong>Current evidence is insufficient to recommend biochemical and lung function tests for tailoring surfactant therapy.</p>\",\"PeriodicalId\":18924,\"journal\":{\"name\":\"Neonatology\",\"volume\":\"120 3\",\"pages\":\"275-286\"},\"PeriodicalIF\":2.6000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Neonatology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1159/000527670\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2022/12/14 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"PEDIATRICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Neonatology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1159/000527670","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/12/14 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"PEDIATRICS","Score":null,"Total":0}
Biochemical and Lung Function Test Accuracy for Predicting the Need for Surfactant Therapy in Preterm Infants: A Systematic Review.
Introduction: We evaluate the accuracy of postnatal biochemical and lung function tests performed within 3 h from birth for predicting surfactant need in preterm infants ≤34 weeks' gestation receiving noninvasive respiratory support for respiratory distress syndrome (RDS).
Methods: We systematically searched MEDLINE, Embase, The Cochrane Library, PROSPERO, and clinicaltrials.gov databases for studies published from 2000 to November 10, 2021, cross-referencing relevant literature and contacting experts. We included diagnostic accuracy studies and systematic reviews of biochemical or lung function tests identifying the need for surfactant in preterm neonates ≤34 weeks' with RDS not intubated at birth. The authors individually assessed the risk of bias following a tailored QUADAS-2 tool.
Results: Eight studies, including 810 infants, met the inclusion criteria. Four tests were included: the click test, the stable microbubble test, the lamellar body count on gastric aspirates, and the forced oscillation technique. The reference standards were transparent criteria for distinguishing the infants according to oxygen requirement, which reflected the current criteria for surfactant therapy. The risk of bias was judged high because of the population selection and exclusion of participants from the analysis. There were no serious concerns regarding blinding and applicability. The individual study sensitivity and specificity range from 0.60 to 1 and from 0.51 to 0.91, respectively. It was not appropriate to combine the accuracy estimates in a meta-analysis because of the heterogeneity of the study characteristics.
Conclusions: Current evidence is insufficient to recommend biochemical and lung function tests for tailoring surfactant therapy.
期刊介绍:
This highly respected and frequently cited journal is a prime source of information in the area of fetal and neonatal research. Original papers present research on all aspects of neonatology, fetal medicine and developmental biology. These papers encompass both basic science and clinical research including randomized trials, observational studies and epidemiology. Basic science research covers molecular biology, molecular genetics, physiology, biochemistry and pharmacology in fetal and neonatal life. In addition to the classic features the journal accepts papers for the sections Research Briefings and Sources of Neonatal Medicine (historical pieces). Papers reporting results of animal studies should be based upon hypotheses that relate to developmental processes or disorders in the human fetus or neonate.