澳大利亚医疗保健提供者使用4种P2/N95口罩或过滤式口罩的合格率:一项前瞻性观察研究

IF 1.1 4区 医学 Q3 ANESTHESIOLOGY
Caitlin Sr Low, Sean Z Ngui, Matthew J Casey, Chloe Vuong, Afsana Afroz, Shomik Sengupta, Laurence Weinberg
{"title":"澳大利亚医疗保健提供者使用4种P2/N95口罩或过滤式口罩的合格率:一项前瞻性观察研究","authors":"Caitlin Sr Low,&nbsp;Sean Z Ngui,&nbsp;Matthew J Casey,&nbsp;Chloe Vuong,&nbsp;Afsana Afroz,&nbsp;Shomik Sengupta,&nbsp;Laurence Weinberg","doi":"10.1177/0310057X231154017","DOIUrl":null,"url":null,"abstract":"<p><p>P2/N95 respirators or filtering facepiece respirators may not have the same pass rate on quantitative fit testing. The aim of this study was to investigate the pass rate of four commonly used filtering facepiece respirators in Australian healthcare providers. The secondary objectives included assessing the ease of donning, doffing and comfort of wearing these four filtering facepiece respirators for more than 30 minutes. A multivariable analysis was also conducted to assess if certain variables (e.g. age, sex, body mass index, ethnicity, facial width and length) were associated with passing or failing fit testing. We conducted a prospective observational study of 150 hospital staff who presented for fit testing in a metropolitan hospital in Victoria, Australia. The order of the four filtering facepiece respirators being tested was randomised. A Cochran's Q test was used to test the global null hypothesis that all four filtering facepiece respirators being tested have the same pass rate. A difference in pass rate was found between the four filtering facepiece respirators that were tested (<i>P</i> < 0.001). The 3M™ Aura 1870+ (3M Australia Pty Ltd, North Ryde, NSW) had the highest pass rate (83%) followed by the 3M™ 1860 (3M Australia Pty Ltd, North Ryde, NSW) (61%), BSN ProShield™ N95 (BSN Medical, Mulgrave, Victoria) (55%) and the BYD DE2322 N95 (BYD Care, Los Angeles, CA, USA) (44%). There was also a difference in the ease of donning, doffing and comfort. Therefore, healthcare facilities that perform fit testing should take these factors into consideration when designing an effective respiratory protection programme.</p>","PeriodicalId":7746,"journal":{"name":"Anaesthesia and Intensive Care","volume":"51 4","pages":"268-273"},"PeriodicalIF":1.1000,"publicationDate":"2023-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Pass rates of four P2/N95 respirators or filtering facepiece respirators in Australian healthcare providers: A prospective observational study.\",\"authors\":\"Caitlin Sr Low,&nbsp;Sean Z Ngui,&nbsp;Matthew J Casey,&nbsp;Chloe Vuong,&nbsp;Afsana Afroz,&nbsp;Shomik Sengupta,&nbsp;Laurence Weinberg\",\"doi\":\"10.1177/0310057X231154017\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>P2/N95 respirators or filtering facepiece respirators may not have the same pass rate on quantitative fit testing. The aim of this study was to investigate the pass rate of four commonly used filtering facepiece respirators in Australian healthcare providers. The secondary objectives included assessing the ease of donning, doffing and comfort of wearing these four filtering facepiece respirators for more than 30 minutes. A multivariable analysis was also conducted to assess if certain variables (e.g. age, sex, body mass index, ethnicity, facial width and length) were associated with passing or failing fit testing. We conducted a prospective observational study of 150 hospital staff who presented for fit testing in a metropolitan hospital in Victoria, Australia. The order of the four filtering facepiece respirators being tested was randomised. A Cochran's Q test was used to test the global null hypothesis that all four filtering facepiece respirators being tested have the same pass rate. A difference in pass rate was found between the four filtering facepiece respirators that were tested (<i>P</i> < 0.001). The 3M™ Aura 1870+ (3M Australia Pty Ltd, North Ryde, NSW) had the highest pass rate (83%) followed by the 3M™ 1860 (3M Australia Pty Ltd, North Ryde, NSW) (61%), BSN ProShield™ N95 (BSN Medical, Mulgrave, Victoria) (55%) and the BYD DE2322 N95 (BYD Care, Los Angeles, CA, USA) (44%). There was also a difference in the ease of donning, doffing and comfort. Therefore, healthcare facilities that perform fit testing should take these factors into consideration when designing an effective respiratory protection programme.</p>\",\"PeriodicalId\":7746,\"journal\":{\"name\":\"Anaesthesia and Intensive Care\",\"volume\":\"51 4\",\"pages\":\"268-273\"},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2023-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Anaesthesia and Intensive Care\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/0310057X231154017\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ANESTHESIOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Anaesthesia and Intensive Care","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/0310057X231154017","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ANESTHESIOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

P2/N95口罩或过滤式口罩在定量配合测试中可能不具有相同的通过率。本研究的目的是调查澳大利亚医疗保健提供者中四种常用过滤式口罩的合格率。次要目标包括评估戴上、脱下这四种过滤式口罩超过30分钟的便利性和舒适度。还进行了多变量分析,以评估某些变量(如年龄、性别、体重指数、种族、面部宽度和长度)是否与匹配测试的通过或失败有关。我们对澳大利亚维多利亚州一家大城市医院的150名医院工作人员进行了前瞻性观察研究。测试的四种过滤式呼吸器的顺序是随机的。使用科克伦Q检验来检验所有四种过滤式口罩的通过率相同的全局零假设。四种过滤式呼吸器的通过率存在差异(P
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Pass rates of four P2/N95 respirators or filtering facepiece respirators in Australian healthcare providers: A prospective observational study.

P2/N95 respirators or filtering facepiece respirators may not have the same pass rate on quantitative fit testing. The aim of this study was to investigate the pass rate of four commonly used filtering facepiece respirators in Australian healthcare providers. The secondary objectives included assessing the ease of donning, doffing and comfort of wearing these four filtering facepiece respirators for more than 30 minutes. A multivariable analysis was also conducted to assess if certain variables (e.g. age, sex, body mass index, ethnicity, facial width and length) were associated with passing or failing fit testing. We conducted a prospective observational study of 150 hospital staff who presented for fit testing in a metropolitan hospital in Victoria, Australia. The order of the four filtering facepiece respirators being tested was randomised. A Cochran's Q test was used to test the global null hypothesis that all four filtering facepiece respirators being tested have the same pass rate. A difference in pass rate was found between the four filtering facepiece respirators that were tested (P < 0.001). The 3M™ Aura 1870+ (3M Australia Pty Ltd, North Ryde, NSW) had the highest pass rate (83%) followed by the 3M™ 1860 (3M Australia Pty Ltd, North Ryde, NSW) (61%), BSN ProShield™ N95 (BSN Medical, Mulgrave, Victoria) (55%) and the BYD DE2322 N95 (BYD Care, Los Angeles, CA, USA) (44%). There was also a difference in the ease of donning, doffing and comfort. Therefore, healthcare facilities that perform fit testing should take these factors into consideration when designing an effective respiratory protection programme.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.70
自引率
13.30%
发文量
150
审稿时长
3 months
期刊介绍: Anaesthesia and Intensive Care is an international journal publishing timely, peer reviewed articles that have educational value and scientific merit for clinicians and researchers associated with anaesthesia, intensive care medicine, and pain medicine.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信