Fangyong Zhu, Lian Ji, Chen Zhou, Yannan Cao, Zhifei Chen, Xiangbing Wu, Jianming Zou, Yufeng Gao
{"title":"三维导向板用于正畸支抗的微种植体植入精度研究。","authors":"Fangyong Zhu, Lian Ji, Chen Zhou, Yannan Cao, Zhifei Chen, Xiangbing Wu, Jianming Zou, Yufeng Gao","doi":"10.1155/2023/9060046","DOIUrl":null,"url":null,"abstract":"<p><p>This study aimed to design a three-dimensional (3D) guide plate using computer-aided design and a 3D printing system for precise implantation of microimplants for orthodontic treatment and investigate the accuracy and feasibility of a 3D guide plate in clinical practice. A total of 30 microimplants were placed in 15 patients in the Department of Stomatology, Affiliated Hospital of Jiangnan University. Before surgery, DICOM data from cone-beam computed tomography (CBCT) scans and STereoLithography data from the 3D model scan were imported to 3Shape Dental System. Data fitting and matching were performed, and 3D guide plates were designed primarily focusing on the thickness of guide plates, amount of concave compensation, and dimensions of the ring. Assist implantation method was used to place the microimplants, and postoperative CBCT images were used to evaluate the position and implantation angle. The feasibility of placing microimplants and precise implantation guided by the 3D guide plate. CBCT data before and after the placement of microimplants were compared. Regarding the secure positioning of microimplants based on CBCT data, 26 implants were categorized as Grade i, four as Grade ii, and none as Grade iii. No loosening of microimplants 1 and 3 months after surgery was reported. The implantation of microimplants is more accurate under the guidance of a 3D guide plate. This technology can achieve accurate implant positioning, thus ensuring safety, stability, and improved success rates after implantation.</p>","PeriodicalId":8029,"journal":{"name":"Applied Bionics and Biomechanics","volume":"2023 ","pages":"9060046"},"PeriodicalIF":1.8000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10317578/pdf/","citationCount":"0","resultStr":"{\"title\":\"Accuracy of Microimplant Placement Using a 3D Guide Plate for Orthodontic Anchorage.\",\"authors\":\"Fangyong Zhu, Lian Ji, Chen Zhou, Yannan Cao, Zhifei Chen, Xiangbing Wu, Jianming Zou, Yufeng Gao\",\"doi\":\"10.1155/2023/9060046\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>This study aimed to design a three-dimensional (3D) guide plate using computer-aided design and a 3D printing system for precise implantation of microimplants for orthodontic treatment and investigate the accuracy and feasibility of a 3D guide plate in clinical practice. A total of 30 microimplants were placed in 15 patients in the Department of Stomatology, Affiliated Hospital of Jiangnan University. Before surgery, DICOM data from cone-beam computed tomography (CBCT) scans and STereoLithography data from the 3D model scan were imported to 3Shape Dental System. Data fitting and matching were performed, and 3D guide plates were designed primarily focusing on the thickness of guide plates, amount of concave compensation, and dimensions of the ring. Assist implantation method was used to place the microimplants, and postoperative CBCT images were used to evaluate the position and implantation angle. The feasibility of placing microimplants and precise implantation guided by the 3D guide plate. CBCT data before and after the placement of microimplants were compared. Regarding the secure positioning of microimplants based on CBCT data, 26 implants were categorized as Grade i, four as Grade ii, and none as Grade iii. No loosening of microimplants 1 and 3 months after surgery was reported. The implantation of microimplants is more accurate under the guidance of a 3D guide plate. This technology can achieve accurate implant positioning, thus ensuring safety, stability, and improved success rates after implantation.</p>\",\"PeriodicalId\":8029,\"journal\":{\"name\":\"Applied Bionics and Biomechanics\",\"volume\":\"2023 \",\"pages\":\"9060046\"},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10317578/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Applied Bionics and Biomechanics\",\"FirstCategoryId\":\"94\",\"ListUrlMain\":\"https://doi.org/10.1155/2023/9060046\",\"RegionNum\":4,\"RegionCategory\":\"计算机科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Applied Bionics and Biomechanics","FirstCategoryId":"94","ListUrlMain":"https://doi.org/10.1155/2023/9060046","RegionNum":4,"RegionCategory":"计算机科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
Accuracy of Microimplant Placement Using a 3D Guide Plate for Orthodontic Anchorage.
This study aimed to design a three-dimensional (3D) guide plate using computer-aided design and a 3D printing system for precise implantation of microimplants for orthodontic treatment and investigate the accuracy and feasibility of a 3D guide plate in clinical practice. A total of 30 microimplants were placed in 15 patients in the Department of Stomatology, Affiliated Hospital of Jiangnan University. Before surgery, DICOM data from cone-beam computed tomography (CBCT) scans and STereoLithography data from the 3D model scan were imported to 3Shape Dental System. Data fitting and matching were performed, and 3D guide plates were designed primarily focusing on the thickness of guide plates, amount of concave compensation, and dimensions of the ring. Assist implantation method was used to place the microimplants, and postoperative CBCT images were used to evaluate the position and implantation angle. The feasibility of placing microimplants and precise implantation guided by the 3D guide plate. CBCT data before and after the placement of microimplants were compared. Regarding the secure positioning of microimplants based on CBCT data, 26 implants were categorized as Grade i, four as Grade ii, and none as Grade iii. No loosening of microimplants 1 and 3 months after surgery was reported. The implantation of microimplants is more accurate under the guidance of a 3D guide plate. This technology can achieve accurate implant positioning, thus ensuring safety, stability, and improved success rates after implantation.
期刊介绍:
Applied Bionics and Biomechanics publishes papers that seek to understand the mechanics of biological systems, or that use the functions of living organisms as inspiration for the design new devices. Such systems may be used as artificial replacements, or aids, for their original biological purpose, or be used in a different setting altogether.