{"title":"评价“即插即用”纳米流液相色谱系统用于临床FFPE标本的MS-based蛋白质组学表征。","authors":"Georgia Mitsa, Vincent R Richard, Yasamin Majedi, Josiane Lafleur, Adriana Aguilar-Mahecha, Mark Basik, Christoph H Borchers","doi":"10.1080/14789450.2023.2219844","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Proteomic analysis of formalin-fixed paraffin-embedded (FFPE) tumor tissue specimens has gained interest in the last 5 years due to technological advances and improved sample collection, as well as biobanking for clinical trials. The real-world implementation of clinical proteomics to these specimens, however, is hampered by tedious sample preparation steps and long instrument acquisition times.</p><p><strong>Areas covered: </strong>To advance the translation of quantitative proteomics into the clinic, we are comparing the performance of the leading commercial nanoflow liquid chromatography (nLC) system (based on literature reviews), the Easy-nLC 1200 (Thermo Fisher Scientific, Waltham, MA, U.S.A.), to the Evosep One HPLC (Evosep Biosystems, Odense, Denmark). We measured FFPE-tissue digests from 21 biological replicates with a similar gradient on both of the LC systems while keeping the on-column amount (1 µg total protein) and the single-shot data-dependent acquisition-based MS/MS method constant.</p><p><strong>Expert opinion: </strong>Overall, the Evosep One facilitates robust and sensitive high-throughput sample acquisition, making it suitable for clinical MS. We found the Evosep One to be a useful platform for positioning mass spectrometry-based proteomics in the clinical setting. The clinical application of nLC/MS will inform clinical decision-making in oncology and other diseases.</p>","PeriodicalId":50463,"journal":{"name":"Expert Review of Proteomics","volume":"20 4-6","pages":"87-92"},"PeriodicalIF":3.8000,"publicationDate":"2023-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of a 'plug and play' nanoflow liquid chromatography system for MS-based proteomic characterization of clinical FFPE specimens.\",\"authors\":\"Georgia Mitsa, Vincent R Richard, Yasamin Majedi, Josiane Lafleur, Adriana Aguilar-Mahecha, Mark Basik, Christoph H Borchers\",\"doi\":\"10.1080/14789450.2023.2219844\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>Proteomic analysis of formalin-fixed paraffin-embedded (FFPE) tumor tissue specimens has gained interest in the last 5 years due to technological advances and improved sample collection, as well as biobanking for clinical trials. The real-world implementation of clinical proteomics to these specimens, however, is hampered by tedious sample preparation steps and long instrument acquisition times.</p><p><strong>Areas covered: </strong>To advance the translation of quantitative proteomics into the clinic, we are comparing the performance of the leading commercial nanoflow liquid chromatography (nLC) system (based on literature reviews), the Easy-nLC 1200 (Thermo Fisher Scientific, Waltham, MA, U.S.A.), to the Evosep One HPLC (Evosep Biosystems, Odense, Denmark). We measured FFPE-tissue digests from 21 biological replicates with a similar gradient on both of the LC systems while keeping the on-column amount (1 µg total protein) and the single-shot data-dependent acquisition-based MS/MS method constant.</p><p><strong>Expert opinion: </strong>Overall, the Evosep One facilitates robust and sensitive high-throughput sample acquisition, making it suitable for clinical MS. We found the Evosep One to be a useful platform for positioning mass spectrometry-based proteomics in the clinical setting. The clinical application of nLC/MS will inform clinical decision-making in oncology and other diseases.</p>\",\"PeriodicalId\":50463,\"journal\":{\"name\":\"Expert Review of Proteomics\",\"volume\":\"20 4-6\",\"pages\":\"87-92\"},\"PeriodicalIF\":3.8000,\"publicationDate\":\"2023-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Expert Review of Proteomics\",\"FirstCategoryId\":\"99\",\"ListUrlMain\":\"https://doi.org/10.1080/14789450.2023.2219844\",\"RegionNum\":3,\"RegionCategory\":\"生物学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"BIOCHEMICAL RESEARCH METHODS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Expert Review of Proteomics","FirstCategoryId":"99","ListUrlMain":"https://doi.org/10.1080/14789450.2023.2219844","RegionNum":3,"RegionCategory":"生物学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
Evaluation of a 'plug and play' nanoflow liquid chromatography system for MS-based proteomic characterization of clinical FFPE specimens.
Introduction: Proteomic analysis of formalin-fixed paraffin-embedded (FFPE) tumor tissue specimens has gained interest in the last 5 years due to technological advances and improved sample collection, as well as biobanking for clinical trials. The real-world implementation of clinical proteomics to these specimens, however, is hampered by tedious sample preparation steps and long instrument acquisition times.
Areas covered: To advance the translation of quantitative proteomics into the clinic, we are comparing the performance of the leading commercial nanoflow liquid chromatography (nLC) system (based on literature reviews), the Easy-nLC 1200 (Thermo Fisher Scientific, Waltham, MA, U.S.A.), to the Evosep One HPLC (Evosep Biosystems, Odense, Denmark). We measured FFPE-tissue digests from 21 biological replicates with a similar gradient on both of the LC systems while keeping the on-column amount (1 µg total protein) and the single-shot data-dependent acquisition-based MS/MS method constant.
Expert opinion: Overall, the Evosep One facilitates robust and sensitive high-throughput sample acquisition, making it suitable for clinical MS. We found the Evosep One to be a useful platform for positioning mass spectrometry-based proteomics in the clinical setting. The clinical application of nLC/MS will inform clinical decision-making in oncology and other diseases.
期刊介绍:
Expert Review of Proteomics (ISSN 1478-9450) seeks to collect together technologies, methods and discoveries from the field of proteomics to advance scientific understanding of the many varied roles protein expression plays in human health and disease.
The journal coverage includes, but is not limited to, overviews of specific technological advances in the development of protein arrays, interaction maps, data archives and biological assays, performance of new technologies and prospects for future drug discovery.
The journal adopts the unique Expert Review article format, offering a complete overview of current thinking in a key technology area, research or clinical practice, augmented by the following sections:
Expert Opinion - a personal view on the most effective or promising strategies and a clear perspective of future prospects within a realistic timescale
Article highlights - an executive summary cutting to the author''s most critical points.