{"title":"透析器几何形状对维持性血液透析患者体外循环凝血激活的影响:前瞻性随机试验。","authors":"Hesham ElSayed, Khalid Samir Sayed, Mohamed Sary Gharib","doi":"10.1111/1744-9987.13975","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and objectives: </strong>The coagulation cascade is activated during hemodialysis (HD) due to interaction of blood with the dialysis circuit. There is a paucity of data on the effect of the physical structure of the dialyzers on coagulation activation during HD. We conducted this study to compare the effect of Helixone FX80 versus Platinum H4 dialyzers on coagulation activation during HD.</p><p><strong>Methods: </strong>Twenty patients on maintenance HD were enrolled in this randomized prospective crossover study. Each patient was dialyzed using Helixone FX80 and Platinum H4 dialyzers. Serum thrombin-antithrombin complex (TAT) was measured before (T0h) and at the end (T4H) of HD.</p><p><strong>Results: </strong>The absolute changes of serum TAT were comparable with the two dialyzers (median [IQR]: 1.15 [0.65, 1.75] for Helixone FX80 vs. 1.15 [0.67, 2.05] for Platinum H4, p = 0.371).</p><p><strong>Conclusion: </strong>Helixone FX80 and Platinum H4 dialyzers have similar effects on coagulation activation during HD.</p>","PeriodicalId":23021,"journal":{"name":"Therapeutic Apheresis and Dialysis","volume":"27 4","pages":"629-635"},"PeriodicalIF":1.5000,"publicationDate":"2023-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Effect of dialyzer geometry on coagulation activation in the extracorporeal circuit in maintenance hemodialysis patients: Prospective randomized trial.\",\"authors\":\"Hesham ElSayed, Khalid Samir Sayed, Mohamed Sary Gharib\",\"doi\":\"10.1111/1744-9987.13975\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background and objectives: </strong>The coagulation cascade is activated during hemodialysis (HD) due to interaction of blood with the dialysis circuit. There is a paucity of data on the effect of the physical structure of the dialyzers on coagulation activation during HD. We conducted this study to compare the effect of Helixone FX80 versus Platinum H4 dialyzers on coagulation activation during HD.</p><p><strong>Methods: </strong>Twenty patients on maintenance HD were enrolled in this randomized prospective crossover study. Each patient was dialyzed using Helixone FX80 and Platinum H4 dialyzers. Serum thrombin-antithrombin complex (TAT) was measured before (T0h) and at the end (T4H) of HD.</p><p><strong>Results: </strong>The absolute changes of serum TAT were comparable with the two dialyzers (median [IQR]: 1.15 [0.65, 1.75] for Helixone FX80 vs. 1.15 [0.67, 2.05] for Platinum H4, p = 0.371).</p><p><strong>Conclusion: </strong>Helixone FX80 and Platinum H4 dialyzers have similar effects on coagulation activation during HD.</p>\",\"PeriodicalId\":23021,\"journal\":{\"name\":\"Therapeutic Apheresis and Dialysis\",\"volume\":\"27 4\",\"pages\":\"629-635\"},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2023-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Therapeutic Apheresis and Dialysis\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1111/1744-9987.13975\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"HEMATOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Therapeutic Apheresis and Dialysis","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/1744-9987.13975","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"HEMATOLOGY","Score":null,"Total":0}
Effect of dialyzer geometry on coagulation activation in the extracorporeal circuit in maintenance hemodialysis patients: Prospective randomized trial.
Background and objectives: The coagulation cascade is activated during hemodialysis (HD) due to interaction of blood with the dialysis circuit. There is a paucity of data on the effect of the physical structure of the dialyzers on coagulation activation during HD. We conducted this study to compare the effect of Helixone FX80 versus Platinum H4 dialyzers on coagulation activation during HD.
Methods: Twenty patients on maintenance HD were enrolled in this randomized prospective crossover study. Each patient was dialyzed using Helixone FX80 and Platinum H4 dialyzers. Serum thrombin-antithrombin complex (TAT) was measured before (T0h) and at the end (T4H) of HD.
Results: The absolute changes of serum TAT were comparable with the two dialyzers (median [IQR]: 1.15 [0.65, 1.75] for Helixone FX80 vs. 1.15 [0.67, 2.05] for Platinum H4, p = 0.371).
Conclusion: Helixone FX80 and Platinum H4 dialyzers have similar effects on coagulation activation during HD.
期刊介绍:
Therapeutic Apheresis and Dialysis is the official peer-reviewed journal of the International Society for Apheresis, the Japanese Society for Apheresis and the Japanese Society for Dialysis Therapy. The Journal publishes original articles, editorial comments, review articles, case reports, meeting abstracts and Communications information on apheresis and dialysis technologies and treatments.