{"title":"基于自适应集成收发波束形成器的合成孔径超声成像。","authors":"Hasti Rostamikhanghahi, Sayed Mahmoud Sakhaei","doi":"10.1177/01617346231163835","DOIUrl":null,"url":null,"abstract":"<p><p>Synthetic aperture (SA) technique is very attractive for ultrafast ultrasound imaging, as the entire medium can be insonified by a single emission. It also permits applying the dynamic focusing as well as adaptive beamforming both in transmission and reception, which results in an enhanced image. In this paper, we firstly show that the problem of designing the transmit and receive beamformers in SA structure can be formulated as a problem of designing a one-way beamformer on a virtual array with a lateral response equal to that of the two-way beamformer on SA. It is also demonstrated that the length of the virtual aperture is increased to the sum of the transmit aperture length and the receive one, which can result in an enhanced resolution. Moreover, a better estimation of the covariance matrix can be obtained which can be utilized for applying adaptive minimum variance (MV) beamforming method on the virtual array, and consequently the resolution and contrast properties would be enhanced. The performance of the new method is compared with other existing MV-based methods and is quantified by some metrics such as the full width at half maximum (FWHM) and generalized contrast to noise ratio (GCNR). Our validations on simulations and experimental data have shown that the new method is capable of obtaining higher GCNR values while retaining or decreasing FWHM values almost all the time. Moreover, for the same subarray length for estimating the covariance matrices, the computational burden of the new method is significantly lower than those of the existing rival methods.</p>","PeriodicalId":49401,"journal":{"name":"Ultrasonic Imaging","volume":null,"pages":null},"PeriodicalIF":2.5000,"publicationDate":"2023-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Synthetic Aperture Ultrasound Imaging through Adaptive Integrated Transmitting-Receiving Beamformer.\",\"authors\":\"Hasti Rostamikhanghahi, Sayed Mahmoud Sakhaei\",\"doi\":\"10.1177/01617346231163835\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Synthetic aperture (SA) technique is very attractive for ultrafast ultrasound imaging, as the entire medium can be insonified by a single emission. It also permits applying the dynamic focusing as well as adaptive beamforming both in transmission and reception, which results in an enhanced image. In this paper, we firstly show that the problem of designing the transmit and receive beamformers in SA structure can be formulated as a problem of designing a one-way beamformer on a virtual array with a lateral response equal to that of the two-way beamformer on SA. It is also demonstrated that the length of the virtual aperture is increased to the sum of the transmit aperture length and the receive one, which can result in an enhanced resolution. Moreover, a better estimation of the covariance matrix can be obtained which can be utilized for applying adaptive minimum variance (MV) beamforming method on the virtual array, and consequently the resolution and contrast properties would be enhanced. The performance of the new method is compared with other existing MV-based methods and is quantified by some metrics such as the full width at half maximum (FWHM) and generalized contrast to noise ratio (GCNR). Our validations on simulations and experimental data have shown that the new method is capable of obtaining higher GCNR values while retaining or decreasing FWHM values almost all the time. Moreover, for the same subarray length for estimating the covariance matrices, the computational burden of the new method is significantly lower than those of the existing rival methods.</p>\",\"PeriodicalId\":49401,\"journal\":{\"name\":\"Ultrasonic Imaging\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.5000,\"publicationDate\":\"2023-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Ultrasonic Imaging\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1177/01617346231163835\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ACOUSTICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ultrasonic Imaging","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1177/01617346231163835","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ACOUSTICS","Score":null,"Total":0}
Synthetic Aperture Ultrasound Imaging through Adaptive Integrated Transmitting-Receiving Beamformer.
Synthetic aperture (SA) technique is very attractive for ultrafast ultrasound imaging, as the entire medium can be insonified by a single emission. It also permits applying the dynamic focusing as well as adaptive beamforming both in transmission and reception, which results in an enhanced image. In this paper, we firstly show that the problem of designing the transmit and receive beamformers in SA structure can be formulated as a problem of designing a one-way beamformer on a virtual array with a lateral response equal to that of the two-way beamformer on SA. It is also demonstrated that the length of the virtual aperture is increased to the sum of the transmit aperture length and the receive one, which can result in an enhanced resolution. Moreover, a better estimation of the covariance matrix can be obtained which can be utilized for applying adaptive minimum variance (MV) beamforming method on the virtual array, and consequently the resolution and contrast properties would be enhanced. The performance of the new method is compared with other existing MV-based methods and is quantified by some metrics such as the full width at half maximum (FWHM) and generalized contrast to noise ratio (GCNR). Our validations on simulations and experimental data have shown that the new method is capable of obtaining higher GCNR values while retaining or decreasing FWHM values almost all the time. Moreover, for the same subarray length for estimating the covariance matrices, the computational burden of the new method is significantly lower than those of the existing rival methods.
期刊介绍:
Ultrasonic Imaging provides rapid publication for original and exceptional papers concerned with the development and application of ultrasonic-imaging technology. Ultrasonic Imaging publishes articles in the following areas: theoretical and experimental aspects of advanced methods and instrumentation for imaging