Kooroush Azartash-Namin, Zheila J Azartash-Namin, S. A. Williams, Khiet Tran, M. Khandaker
{"title":"聚乙烯醇/聚乙烯吡咯烷酮(PVA/PVP)椎间盘聚合物的力学性能","authors":"Kooroush Azartash-Namin, Zheila J Azartash-Namin, S. A. Williams, Khiet Tran, M. Khandaker","doi":"10.1115/IMECE2013-64767","DOIUrl":null,"url":null,"abstract":"The intervertebral disc is one of the body’s most vital structures. It provides support and enables six degree of freedom (6DOF) motions in the spine: flexion, extension, right and left lateral bending, compression, and axial rotation. When individuals suffer from degenerative disc disease, the nucleus pulposus deteriorates, causing a loss of articulation in the intervertebral disc. To address this problem, replacements for the nucleus pulposus can be used. The objective of this study was to evaluate a potential nucleus pulposus replacement consisting of a hydrogel polymer. The hydrogel was synthesized by physically cross-linking 95%-weight polyvinyl alcohol (PVA) and 5%-weight polyvinyl pyrrolidone (PVP). PVA and PVP were selected for the hydrogel implant due to the natural biocompatibility when the two are physically cross-linked. In order to evaluate the mechanical effectiveness of the hydrogel, a slider-crank mechanism was designed and constructed to create the 6DOF motions when interfaced with a Universal Mechanical Testing System. The viscoelastic properties of the polymer were obtained using a rheometer, which determined the elastic (G′) and viscous (G″) moduli of the PVA/PVP hydrogel polymer by calculating the complex shear modulus (G*) under low-frequency oscillating shear deformation. This allows for study of the viscoelastic performance of the isolated nucleus pulposus and hydrogel implant. The elastic modulus of the hydrogel was tested at parameters 5%, 10%, and 15% strain with results of 228.6 Pa, 988.8 Pa, and 1793 Pa, respectively. However, the elastic modulus tested for the natural bovine specimen at 5%, 10%, and 15% strain were 712.9 Pa, 522.1 Pa, and 363.3 Pa, respectively.Copyright © 2013 by ASME","PeriodicalId":0,"journal":{"name":"","volume":" ","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-11-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Mechanical Effectiveness of Polyvinyl Alcohol/Polyvinyl Pyrrolidone (PVA/PVP) as an Intervertebral Disc Polymer\",\"authors\":\"Kooroush Azartash-Namin, Zheila J Azartash-Namin, S. A. Williams, Khiet Tran, M. Khandaker\",\"doi\":\"10.1115/IMECE2013-64767\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The intervertebral disc is one of the body’s most vital structures. It provides support and enables six degree of freedom (6DOF) motions in the spine: flexion, extension, right and left lateral bending, compression, and axial rotation. When individuals suffer from degenerative disc disease, the nucleus pulposus deteriorates, causing a loss of articulation in the intervertebral disc. To address this problem, replacements for the nucleus pulposus can be used. The objective of this study was to evaluate a potential nucleus pulposus replacement consisting of a hydrogel polymer. The hydrogel was synthesized by physically cross-linking 95%-weight polyvinyl alcohol (PVA) and 5%-weight polyvinyl pyrrolidone (PVP). PVA and PVP were selected for the hydrogel implant due to the natural biocompatibility when the two are physically cross-linked. In order to evaluate the mechanical effectiveness of the hydrogel, a slider-crank mechanism was designed and constructed to create the 6DOF motions when interfaced with a Universal Mechanical Testing System. The viscoelastic properties of the polymer were obtained using a rheometer, which determined the elastic (G′) and viscous (G″) moduli of the PVA/PVP hydrogel polymer by calculating the complex shear modulus (G*) under low-frequency oscillating shear deformation. This allows for study of the viscoelastic performance of the isolated nucleus pulposus and hydrogel implant. The elastic modulus of the hydrogel was tested at parameters 5%, 10%, and 15% strain with results of 228.6 Pa, 988.8 Pa, and 1793 Pa, respectively. However, the elastic modulus tested for the natural bovine specimen at 5%, 10%, and 15% strain were 712.9 Pa, 522.1 Pa, and 363.3 Pa, respectively.Copyright © 2013 by ASME\",\"PeriodicalId\":0,\"journal\":{\"name\":\"\",\"volume\":\" \",\"pages\":\"0\"},\"PeriodicalIF\":0.0,\"publicationDate\":\"2013-11-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1115/IMECE2013-64767\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1115/IMECE2013-64767","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2
Mechanical Effectiveness of Polyvinyl Alcohol/Polyvinyl Pyrrolidone (PVA/PVP) as an Intervertebral Disc Polymer
The intervertebral disc is one of the body’s most vital structures. It provides support and enables six degree of freedom (6DOF) motions in the spine: flexion, extension, right and left lateral bending, compression, and axial rotation. When individuals suffer from degenerative disc disease, the nucleus pulposus deteriorates, causing a loss of articulation in the intervertebral disc. To address this problem, replacements for the nucleus pulposus can be used. The objective of this study was to evaluate a potential nucleus pulposus replacement consisting of a hydrogel polymer. The hydrogel was synthesized by physically cross-linking 95%-weight polyvinyl alcohol (PVA) and 5%-weight polyvinyl pyrrolidone (PVP). PVA and PVP were selected for the hydrogel implant due to the natural biocompatibility when the two are physically cross-linked. In order to evaluate the mechanical effectiveness of the hydrogel, a slider-crank mechanism was designed and constructed to create the 6DOF motions when interfaced with a Universal Mechanical Testing System. The viscoelastic properties of the polymer were obtained using a rheometer, which determined the elastic (G′) and viscous (G″) moduli of the PVA/PVP hydrogel polymer by calculating the complex shear modulus (G*) under low-frequency oscillating shear deformation. This allows for study of the viscoelastic performance of the isolated nucleus pulposus and hydrogel implant. The elastic modulus of the hydrogel was tested at parameters 5%, 10%, and 15% strain with results of 228.6 Pa, 988.8 Pa, and 1793 Pa, respectively. However, the elastic modulus tested for the natural bovine specimen at 5%, 10%, and 15% strain were 712.9 Pa, 522.1 Pa, and 363.3 Pa, respectively.Copyright © 2013 by ASME