Elaine A Lopes-Garcia, Elenice V Carmona, Ilza Monteiro, Luis Bahamondes
{"title":"根据装置类型、胎次和分娩方式评估宫内节育器放置的疼痛和容易程度。","authors":"Elaine A Lopes-Garcia, Elenice V Carmona, Ilza Monteiro, Luis Bahamondes","doi":"10.1080/13625187.2023.2189500","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>We compared pain and the ease of insertion of two different types of intrauterine devices (IUDs; the levonorgestrel intrauterine systems 52 mg (LNG-IUS 52 mg) and the copper-bearing IUD [TCu380A]) among nulligravidas and parous women with and without caesarean delivery.</p><p><strong>Methods: </strong>A cross-sectional study assessed pain referred by women and ease of insertion of the two IUDs models. We applied a visual analogue scale (VAS) to assess pain, while the ease of insertion was defined by healthcare professionals.</p><p><strong>Results: </strong>We assessed 1076 women, including 334 nulligravidas and 566 parous women who had had at least one caesarean delivery and 176 women with history of only vaginal delivery. Regarding pain at IUD placement, 26 (2.5%) women reported no pain, 167 (16.4%) light pain, 319 (31.3%) moderate and 506 (49.7%) intense pain. The highest scores for pain were reported by nulligravidas (67.2%, <i>p</i> = 0.001), while the mean pain score was higher in the LNG-IUS 52 mg group. Difficulties reported by healthcare providers were more frequent in the nulligravidas (21.2%) and women with previous caesarean delivery (16.9%).</p><p><strong>Conclusions: </strong>Our findings suggested differences between the two IUDs tested, with higher pain associated with the LNG-IUS 52 mg, and highlights the need for pain management, mainly among nulligravida and women with history of caesarean delivery.SHORT CONDENSATIONIntense pain at insertion was more related to nulligravida than parous women and more pain with placement of LNG-IUS 52 mg IUDs than TCu380A IUDs. Nevertheless, our results confirmed that ease of IUD placement was between 80% to 90% of all insertions, being more common in parous women without previous caesarean delivery.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2023-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Assessment of pain and ease of intrauterine device placement according to type of device, parity, and mode of delivery.\",\"authors\":\"Elaine A Lopes-Garcia, Elenice V Carmona, Ilza Monteiro, Luis Bahamondes\",\"doi\":\"10.1080/13625187.2023.2189500\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>We compared pain and the ease of insertion of two different types of intrauterine devices (IUDs; the levonorgestrel intrauterine systems 52 mg (LNG-IUS 52 mg) and the copper-bearing IUD [TCu380A]) among nulligravidas and parous women with and without caesarean delivery.</p><p><strong>Methods: </strong>A cross-sectional study assessed pain referred by women and ease of insertion of the two IUDs models. We applied a visual analogue scale (VAS) to assess pain, while the ease of insertion was defined by healthcare professionals.</p><p><strong>Results: </strong>We assessed 1076 women, including 334 nulligravidas and 566 parous women who had had at least one caesarean delivery and 176 women with history of only vaginal delivery. Regarding pain at IUD placement, 26 (2.5%) women reported no pain, 167 (16.4%) light pain, 319 (31.3%) moderate and 506 (49.7%) intense pain. The highest scores for pain were reported by nulligravidas (67.2%, <i>p</i> = 0.001), while the mean pain score was higher in the LNG-IUS 52 mg group. Difficulties reported by healthcare providers were more frequent in the nulligravidas (21.2%) and women with previous caesarean delivery (16.9%).</p><p><strong>Conclusions: </strong>Our findings suggested differences between the two IUDs tested, with higher pain associated with the LNG-IUS 52 mg, and highlights the need for pain management, mainly among nulligravida and women with history of caesarean delivery.SHORT CONDENSATIONIntense pain at insertion was more related to nulligravida than parous women and more pain with placement of LNG-IUS 52 mg IUDs than TCu380A IUDs. Nevertheless, our results confirmed that ease of IUD placement was between 80% to 90% of all insertions, being more common in parous women without previous caesarean delivery.</p>\",\"PeriodicalId\":1,\"journal\":{\"name\":\"Accounts of Chemical Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":16.4000,\"publicationDate\":\"2023-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accounts of Chemical Research\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1080/13625187.2023.2189500\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/13625187.2023.2189500","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
Assessment of pain and ease of intrauterine device placement according to type of device, parity, and mode of delivery.
Objective: We compared pain and the ease of insertion of two different types of intrauterine devices (IUDs; the levonorgestrel intrauterine systems 52 mg (LNG-IUS 52 mg) and the copper-bearing IUD [TCu380A]) among nulligravidas and parous women with and without caesarean delivery.
Methods: A cross-sectional study assessed pain referred by women and ease of insertion of the two IUDs models. We applied a visual analogue scale (VAS) to assess pain, while the ease of insertion was defined by healthcare professionals.
Results: We assessed 1076 women, including 334 nulligravidas and 566 parous women who had had at least one caesarean delivery and 176 women with history of only vaginal delivery. Regarding pain at IUD placement, 26 (2.5%) women reported no pain, 167 (16.4%) light pain, 319 (31.3%) moderate and 506 (49.7%) intense pain. The highest scores for pain were reported by nulligravidas (67.2%, p = 0.001), while the mean pain score was higher in the LNG-IUS 52 mg group. Difficulties reported by healthcare providers were more frequent in the nulligravidas (21.2%) and women with previous caesarean delivery (16.9%).
Conclusions: Our findings suggested differences between the two IUDs tested, with higher pain associated with the LNG-IUS 52 mg, and highlights the need for pain management, mainly among nulligravida and women with history of caesarean delivery.SHORT CONDENSATIONIntense pain at insertion was more related to nulligravida than parous women and more pain with placement of LNG-IUS 52 mg IUDs than TCu380A IUDs. Nevertheless, our results confirmed that ease of IUD placement was between 80% to 90% of all insertions, being more common in parous women without previous caesarean delivery.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.