使用夹板或不使用夹板相邻种植体?一项长达15年的回顾性研究:第一部分-生物和机械并发症分析。

IF 16.4 1区 化学 Q1 CHEMISTRY, MULTIDISCIPLINARY
Yuseung Yi, Seong-Joo Heo, Jai-Young Koak, Seong-Kyun Kim, Ki-Tae Koo
{"title":"使用夹板或不使用夹板相邻种植体?一项长达15年的回顾性研究:第一部分-生物和机械并发症分析。","authors":"Yuseung Yi,&nbsp;Seong-Joo Heo,&nbsp;Jai-Young Koak,&nbsp;Seong-Kyun Kim,&nbsp;Ki-Tae Koo","doi":"10.11607/jomi.10053","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To analyze the biologic and mechanical complications of splinted and nonsplinted implant restorations.</p><p><strong>Materials and methods: </strong>A total of 423 patients (n = implants: 888) were included in the study. Biologic and mechanical complications that occurred for 15 years were analyzed using the multivariable Cox regression model, and the significant effect of the splinting of prostheses and other risk factors were evaluated.</p><p><strong>Results: </strong>Biologic complications occurred in 38.7% of implants: 26.4% of nonsplinted implants (NS) and 45.4% of splinted implants (SP). Mechanical complications occurred in 49.2% of implants: 59.3% NS and 43.9% SP. Implants splinted with both mesial and distal adjacent implants (SP-mid) had the highest risk of peri-implant diseases. As the number of implants splinted increased, the risk of mechanical complications decreased. Long crown lengths increased the risk of both biologic and mechanical complications.</p><p><strong>Conclusion: </strong>Splinted implants had a higher risk of biologic complications and lower risk of mechanical complications. The implant splinted to both adjacent implants (SP-mid) had the highest risk of biologic complications. The greater the number of implants splinted, the lower the risk of mechanical complications. Long crown lengths increased the risk of both biologic and mechanical complications. Int J Oral Maxillofac Implants 2023;38:435-442. doi: 10.11607/jomi.10053.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2023-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Splinting or Nonsplinting Adjacent Implants? A Retrospective Study Up to 15 Years: Part I-Biologic and Mechanical Complication Analysis.\",\"authors\":\"Yuseung Yi,&nbsp;Seong-Joo Heo,&nbsp;Jai-Young Koak,&nbsp;Seong-Kyun Kim,&nbsp;Ki-Tae Koo\",\"doi\":\"10.11607/jomi.10053\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To analyze the biologic and mechanical complications of splinted and nonsplinted implant restorations.</p><p><strong>Materials and methods: </strong>A total of 423 patients (n = implants: 888) were included in the study. Biologic and mechanical complications that occurred for 15 years were analyzed using the multivariable Cox regression model, and the significant effect of the splinting of prostheses and other risk factors were evaluated.</p><p><strong>Results: </strong>Biologic complications occurred in 38.7% of implants: 26.4% of nonsplinted implants (NS) and 45.4% of splinted implants (SP). Mechanical complications occurred in 49.2% of implants: 59.3% NS and 43.9% SP. Implants splinted with both mesial and distal adjacent implants (SP-mid) had the highest risk of peri-implant diseases. As the number of implants splinted increased, the risk of mechanical complications decreased. Long crown lengths increased the risk of both biologic and mechanical complications.</p><p><strong>Conclusion: </strong>Splinted implants had a higher risk of biologic complications and lower risk of mechanical complications. The implant splinted to both adjacent implants (SP-mid) had the highest risk of biologic complications. The greater the number of implants splinted, the lower the risk of mechanical complications. Long crown lengths increased the risk of both biologic and mechanical complications. Int J Oral Maxillofac Implants 2023;38:435-442. doi: 10.11607/jomi.10053.</p>\",\"PeriodicalId\":1,\"journal\":{\"name\":\"Accounts of Chemical Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":16.4000,\"publicationDate\":\"2023-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accounts of Chemical Research\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.11607/jomi.10053\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.11607/jomi.10053","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 1

摘要

目的:分析有夹板和无夹板种植体修复体的生物学和力学并发症。材料与方法:共纳入423例患者(n =种植体:888例)。采用多变量Cox回归模型分析15年内发生的生物和机械并发症,评估假体夹板及其他危险因素的显著影响。结果:生物并发症发生率为38.7%,无夹板种植体(NS) 26.4%,有夹板种植体(SP) 45.4%。机械并发症发生在49.2%的种植体中:59.3%的NS和43.9%的SP。种植体夹板与近中和远端相邻种植体(SP-mid)有种植体周围疾病的最高风险。随着植入物数量的增加,机械并发症的风险降低。冠长增加了生物和机械并发症的风险。结论:夹板种植体发生生物并发症的风险较高,机械并发症的风险较低。与相邻种植体(SP-mid)夹板固定的种植体发生生物并发症的风险最高。固定的种植体数量越多,机械并发症的风险越低。冠长增加了生物和机械并发症的风险。口腔颌面种植[J]; 2009;38(8): 335 -442。doi: 10.11607 / jomi.10053。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Splinting or Nonsplinting Adjacent Implants? A Retrospective Study Up to 15 Years: Part I-Biologic and Mechanical Complication Analysis.

Purpose: To analyze the biologic and mechanical complications of splinted and nonsplinted implant restorations.

Materials and methods: A total of 423 patients (n = implants: 888) were included in the study. Biologic and mechanical complications that occurred for 15 years were analyzed using the multivariable Cox regression model, and the significant effect of the splinting of prostheses and other risk factors were evaluated.

Results: Biologic complications occurred in 38.7% of implants: 26.4% of nonsplinted implants (NS) and 45.4% of splinted implants (SP). Mechanical complications occurred in 49.2% of implants: 59.3% NS and 43.9% SP. Implants splinted with both mesial and distal adjacent implants (SP-mid) had the highest risk of peri-implant diseases. As the number of implants splinted increased, the risk of mechanical complications decreased. Long crown lengths increased the risk of both biologic and mechanical complications.

Conclusion: Splinted implants had a higher risk of biologic complications and lower risk of mechanical complications. The implant splinted to both adjacent implants (SP-mid) had the highest risk of biologic complications. The greater the number of implants splinted, the lower the risk of mechanical complications. Long crown lengths increased the risk of both biologic and mechanical complications. Int J Oral Maxillofac Implants 2023;38:435-442. doi: 10.11607/jomi.10053.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Accounts of Chemical Research
Accounts of Chemical Research 化学-化学综合
CiteScore
31.40
自引率
1.10%
发文量
312
审稿时长
2 months
期刊介绍: Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance. Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信