Waheed Ali Laghari, Audrey Huong, Kim Gaik Tay, Chang Choon Chew
{"title":"手背静脉模式识别:手动和自动分割方法的比较。","authors":"Waheed Ali Laghari, Audrey Huong, Kim Gaik Tay, Chang Choon Chew","doi":"10.4258/hir.2023.29.2.152","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>Various techniques for dorsal hand vein (DHV) pattern extraction have been introduced using small datasets with poor and inconsistent segmentation. This work compared manual segmentation with our proposed hybrid automatic segmentation method (HHM) for this classification problem.</p><p><strong>Methods: </strong>Manual segmentation involved selecting a region-of-interest (ROI) in images from the Bosphorus dataset to generate ground truth data. The HHM combined histogram equalization and morphological and thresholding-based algorithms to localize veins from hand images. The data were divided into training, validation, and testing sets with an 8:1:1 ratio before training AlexNet. We considered three image augmentation strategies to enlarge our training sets. The best training hyperparameters were found using the manually segmented dataset.</p><p><strong>Results: </strong>We obtained a good test accuracy (91.5%) using the model trained with manually segmented images. The HHM method showed slightly inferior performance (76.5%). Considerable improvement was observed in the test accuracy of the model trained with the inclusion of automatically segmented and augmented images (84%), with low false acceptance and false rejection rates (0.00035% and 0.095%, respectively). A comparison with past studies further demonstrated the competitiveness of our technique.</p><p><strong>Conclusions: </strong>Our technique can be feasible for extracting the ROI in DHV images. This strategy provides higher consistency and greater efficiency than the manual approach.</p>","PeriodicalId":12947,"journal":{"name":"Healthcare Informatics Research","volume":null,"pages":null},"PeriodicalIF":2.3000,"publicationDate":"2023-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/b5/11/hir-2023-29-2-152.PMC10209724.pdf","citationCount":"0","resultStr":"{\"title\":\"Dorsal Hand Vein Pattern Recognition: A Comparison between Manual and Automatic Segmentation Methods.\",\"authors\":\"Waheed Ali Laghari, Audrey Huong, Kim Gaik Tay, Chang Choon Chew\",\"doi\":\"10.4258/hir.2023.29.2.152\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>Various techniques for dorsal hand vein (DHV) pattern extraction have been introduced using small datasets with poor and inconsistent segmentation. This work compared manual segmentation with our proposed hybrid automatic segmentation method (HHM) for this classification problem.</p><p><strong>Methods: </strong>Manual segmentation involved selecting a region-of-interest (ROI) in images from the Bosphorus dataset to generate ground truth data. The HHM combined histogram equalization and morphological and thresholding-based algorithms to localize veins from hand images. The data were divided into training, validation, and testing sets with an 8:1:1 ratio before training AlexNet. We considered three image augmentation strategies to enlarge our training sets. The best training hyperparameters were found using the manually segmented dataset.</p><p><strong>Results: </strong>We obtained a good test accuracy (91.5%) using the model trained with manually segmented images. The HHM method showed slightly inferior performance (76.5%). Considerable improvement was observed in the test accuracy of the model trained with the inclusion of automatically segmented and augmented images (84%), with low false acceptance and false rejection rates (0.00035% and 0.095%, respectively). A comparison with past studies further demonstrated the competitiveness of our technique.</p><p><strong>Conclusions: </strong>Our technique can be feasible for extracting the ROI in DHV images. This strategy provides higher consistency and greater efficiency than the manual approach.</p>\",\"PeriodicalId\":12947,\"journal\":{\"name\":\"Healthcare Informatics Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2023-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/b5/11/hir-2023-29-2-152.PMC10209724.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Healthcare Informatics Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4258/hir.2023.29.2.152\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"MEDICAL INFORMATICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Healthcare Informatics Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4258/hir.2023.29.2.152","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MEDICAL INFORMATICS","Score":null,"Total":0}
Dorsal Hand Vein Pattern Recognition: A Comparison between Manual and Automatic Segmentation Methods.
Objectives: Various techniques for dorsal hand vein (DHV) pattern extraction have been introduced using small datasets with poor and inconsistent segmentation. This work compared manual segmentation with our proposed hybrid automatic segmentation method (HHM) for this classification problem.
Methods: Manual segmentation involved selecting a region-of-interest (ROI) in images from the Bosphorus dataset to generate ground truth data. The HHM combined histogram equalization and morphological and thresholding-based algorithms to localize veins from hand images. The data were divided into training, validation, and testing sets with an 8:1:1 ratio before training AlexNet. We considered three image augmentation strategies to enlarge our training sets. The best training hyperparameters were found using the manually segmented dataset.
Results: We obtained a good test accuracy (91.5%) using the model trained with manually segmented images. The HHM method showed slightly inferior performance (76.5%). Considerable improvement was observed in the test accuracy of the model trained with the inclusion of automatically segmented and augmented images (84%), with low false acceptance and false rejection rates (0.00035% and 0.095%, respectively). A comparison with past studies further demonstrated the competitiveness of our technique.
Conclusions: Our technique can be feasible for extracting the ROI in DHV images. This strategy provides higher consistency and greater efficiency than the manual approach.