国家急诊x线摄影应用研究(NEXUS)胸部算法与创伤超声扩展聚焦评估(E-FAST)在多发创伤患者钝性胸部损伤早期检测中的比较研究

IF 1.4 4区 医学 Q3 EMERGENCY MEDICINE
Yasmin Z. Attia , Nashwa M. Abd Elgeleel , Hazem M. El-Hariri , Gouda M. Ellabban , Maged El-SETOUHY , Jon Mark Hirshon , Adel H Elbaih , Mohamed El-Shinawi
{"title":"国家急诊x线摄影应用研究(NEXUS)胸部算法与创伤超声扩展聚焦评估(E-FAST)在多发创伤患者钝性胸部损伤早期检测中的比较研究","authors":"Yasmin Z. Attia ,&nbsp;Nashwa M. Abd Elgeleel ,&nbsp;Hazem M. El-Hariri ,&nbsp;Gouda M. Ellabban ,&nbsp;Maged El-SETOUHY ,&nbsp;Jon Mark Hirshon ,&nbsp;Adel H Elbaih ,&nbsp;Mohamed El-Shinawi","doi":"10.1016/j.afjem.2023.02.003","DOIUrl":null,"url":null,"abstract":"<div><h3>Introduction</h3><p>Chest imaging plays a prominent role in the assessment of patients with blunt trauma. Selection of the right approach at the right time is fundamental in the management of patients with blunt chest trauma<sup>.</sup><span>[1]</span> A reliable, economic, bedside, and rapidly accomplished screening test can be pivotal. <span>[2]</span></p></div><div><h3>Objective</h3><p>The aim of this study was to compare the accuracy of extended- focused assessment with sonography for trauma (E-FAST) to that of the National Emergency X-Radiography Utilisation Study (NEXUS) chest algorithm in detecting blunt chest injuries.</p></div><div><h3>Methods</h3><p>This descriptive cross-sectional study included 50 polytrauma patients with blunt chest trauma from the emergency centre of Suez Canal University Hospital. E-FAST and computed tomography (CT) were conducted, followed by reporting of NEXUS criteria for all patients. Blinding of the E-FAST performer and CT reporter were confirmed. The results of both the NEXUS algorithm and E-FAST were compared with CT chest results.</p></div><div><h3>Results</h3><p>The NEXUS algorithm had 100% sensitivity and 15.3% specificity, and E-FAST had 70% sensitivity and 96.7% specificity, in the detection of pneumothorax.</p><p>In the detection of hemothorax, the sensitivity and specificity of the NEXUS algorithm were 90% and 7.5%, respectively, whereas E-FAST had a lower sensitivity of 80% and a higher specificity of 97.5%.</p></div><div><h3>Conclusion</h3><p>E-FAST is highly specific for the detection of hemothorax, pneumothorax, and chest injuries compared with the NEXUS chest algorithm, which demonstrated the lowest specificity. However, the NEXUS chest algorithm showed a higher sensitivity than E-FAST and hence can be used effectively to rule out thoracic injury.</p></div>","PeriodicalId":48515,"journal":{"name":"African Journal of Emergency Medicine","volume":null,"pages":null},"PeriodicalIF":1.4000,"publicationDate":"2023-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/17/f5/main.PMC10014268.pdf","citationCount":"0","resultStr":"{\"title\":\"Comparative study of National Emergency X-Radiography Utilization Study (NEXUS) chest algorithm and extended focused assessment with sonography for trauma (E-FAST) in the early detection of blunt chest injuries in polytrauma patients\",\"authors\":\"Yasmin Z. Attia ,&nbsp;Nashwa M. Abd Elgeleel ,&nbsp;Hazem M. El-Hariri ,&nbsp;Gouda M. Ellabban ,&nbsp;Maged El-SETOUHY ,&nbsp;Jon Mark Hirshon ,&nbsp;Adel H Elbaih ,&nbsp;Mohamed El-Shinawi\",\"doi\":\"10.1016/j.afjem.2023.02.003\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Introduction</h3><p>Chest imaging plays a prominent role in the assessment of patients with blunt trauma. Selection of the right approach at the right time is fundamental in the management of patients with blunt chest trauma<sup>.</sup><span>[1]</span> A reliable, economic, bedside, and rapidly accomplished screening test can be pivotal. <span>[2]</span></p></div><div><h3>Objective</h3><p>The aim of this study was to compare the accuracy of extended- focused assessment with sonography for trauma (E-FAST) to that of the National Emergency X-Radiography Utilisation Study (NEXUS) chest algorithm in detecting blunt chest injuries.</p></div><div><h3>Methods</h3><p>This descriptive cross-sectional study included 50 polytrauma patients with blunt chest trauma from the emergency centre of Suez Canal University Hospital. E-FAST and computed tomography (CT) were conducted, followed by reporting of NEXUS criteria for all patients. Blinding of the E-FAST performer and CT reporter were confirmed. The results of both the NEXUS algorithm and E-FAST were compared with CT chest results.</p></div><div><h3>Results</h3><p>The NEXUS algorithm had 100% sensitivity and 15.3% specificity, and E-FAST had 70% sensitivity and 96.7% specificity, in the detection of pneumothorax.</p><p>In the detection of hemothorax, the sensitivity and specificity of the NEXUS algorithm were 90% and 7.5%, respectively, whereas E-FAST had a lower sensitivity of 80% and a higher specificity of 97.5%.</p></div><div><h3>Conclusion</h3><p>E-FAST is highly specific for the detection of hemothorax, pneumothorax, and chest injuries compared with the NEXUS chest algorithm, which demonstrated the lowest specificity. However, the NEXUS chest algorithm showed a higher sensitivity than E-FAST and hence can be used effectively to rule out thoracic injury.</p></div>\",\"PeriodicalId\":48515,\"journal\":{\"name\":\"African Journal of Emergency Medicine\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2023-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/17/f5/main.PMC10014268.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"African Journal of Emergency Medicine\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2211419X23000083\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"EMERGENCY MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"African Journal of Emergency Medicine","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2211419X23000083","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"EMERGENCY MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

胸部影像学在钝性创伤患者的评估中起着重要作用。在正确的时间选择正确的方法是钝性胸部创伤患者治疗的基础。[1] 一种可靠、经济、床边且快速完成的筛查测试可能至关重要。[2] 目的本研究的目的是比较超声创伤扩展聚焦评估(E-FAST)和国家急诊X射线成像应用研究(NEXUS)胸部算法检测钝性胸部损伤的准确性。方法这项描述性横断面研究包括来自苏伊士运河大学医院急诊中心的50名胸部钝性创伤的多发伤患者。进行E-FAST和计算机断层扫描(CT),然后报告所有患者的NEXUS标准。确认E-FAST执行者和CT报告者失明。NEXUS算法和E-FAST的结果与CT胸部结果进行了比较。结果NEXUS算法在检测肺气肿中具有100%的敏感性和15.3%的特异性,E-FAST算法在检测中具有70%的敏感性和96.7%的特异性。在血胸检测中,NEXUS算法的灵敏度和特异性分别为90%和7.5%,而E-FAST的灵敏度较低,为80%,特异性较高,为97.5%。然而,NEXUS胸部算法显示出比E-FAST更高的灵敏度,因此可以有效地用于排除胸部损伤。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Comparative study of National Emergency X-Radiography Utilization Study (NEXUS) chest algorithm and extended focused assessment with sonography for trauma (E-FAST) in the early detection of blunt chest injuries in polytrauma patients

Comparative study of National Emergency X-Radiography Utilization Study (NEXUS) chest algorithm and extended focused assessment with sonography for trauma (E-FAST) in the early detection of blunt chest injuries in polytrauma patients

Introduction

Chest imaging plays a prominent role in the assessment of patients with blunt trauma. Selection of the right approach at the right time is fundamental in the management of patients with blunt chest trauma.[1] A reliable, economic, bedside, and rapidly accomplished screening test can be pivotal. [2]

Objective

The aim of this study was to compare the accuracy of extended- focused assessment with sonography for trauma (E-FAST) to that of the National Emergency X-Radiography Utilisation Study (NEXUS) chest algorithm in detecting blunt chest injuries.

Methods

This descriptive cross-sectional study included 50 polytrauma patients with blunt chest trauma from the emergency centre of Suez Canal University Hospital. E-FAST and computed tomography (CT) were conducted, followed by reporting of NEXUS criteria for all patients. Blinding of the E-FAST performer and CT reporter were confirmed. The results of both the NEXUS algorithm and E-FAST were compared with CT chest results.

Results

The NEXUS algorithm had 100% sensitivity and 15.3% specificity, and E-FAST had 70% sensitivity and 96.7% specificity, in the detection of pneumothorax.

In the detection of hemothorax, the sensitivity and specificity of the NEXUS algorithm were 90% and 7.5%, respectively, whereas E-FAST had a lower sensitivity of 80% and a higher specificity of 97.5%.

Conclusion

E-FAST is highly specific for the detection of hemothorax, pneumothorax, and chest injuries compared with the NEXUS chest algorithm, which demonstrated the lowest specificity. However, the NEXUS chest algorithm showed a higher sensitivity than E-FAST and hence can be used effectively to rule out thoracic injury.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.40
自引率
7.70%
发文量
78
审稿时长
85 days
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信