Jason N Mehta, Brianna E Morales, John H Rossmeisl, Waldemar Debinski, Christopher G Rylander
{"title":"毛细管内固体光纤和改进的熔接光纤微针装置提高光传输效率。","authors":"Jason N Mehta, Brianna E Morales, John H Rossmeisl, Waldemar Debinski, Christopher G Rylander","doi":"10.1115/1.4055607","DOIUrl":null,"url":null,"abstract":"<p><p>Convection-enhanced delivery (CED) is a drug delivery technique used to deliver therapeutics directly to the brain and is a continually evolving technique to treat glioblastoma. Early versions of CED have proven to result in inadequate drug volume dispersed (V<sub>d</sub>), increasing the likelihood of tumor recurrence. Fiber optic microneedle devices (FMDs) with the ability to deliver fluid and thermal energy simultaneously have shown an ability to increase V<sub>d</sub>, but FMDs have historically had low light transmission efficiency. In this study, we present a new fabrication method, solid fiber inside capillary (SFIC) FMD, and a modified fusion splicing (FS) method with the goal of increasing light delivery efficiency. The modified FS FMD resulted in an increase in light transmission efficiency between 49% and 173% compared to previous prototypes. However, the FS FMD resulted in significantly lower transmission efficiencies compared to the SFIC FMD (p ≤ 0.04) and FS FMDs perform much worse when light-absorptive materials, like black dye, are placed in the bore. The light absorption of a candidate cytotoxic agent, QUAD-CTX, appear to be similar to water, and light delivery through FS FMDs filled with QUAD-CTX achieves a transmission efficiency of 85.6 ± 5.4%. The fabrication process of the SFIC FMDs results in extremely fragile FMDs. Therefore, the use of a modified FS FMD fabrication process appears to be better suited for balancing the desire to increase light transmission efficiency while retaining a sturdy FMD construction.</p>","PeriodicalId":49305,"journal":{"name":"Journal of Medical Devices-Transactions of the Asme","volume":null,"pages":null},"PeriodicalIF":0.8000,"publicationDate":"2022-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9632479/pdf/","citationCount":"0","resultStr":"{\"title\":\"Solid Fiber Inside of Capillary and Modified Fusion-Spliced Fiber Optic Microneedle Devices for Improved Light Transmission Efficiency.\",\"authors\":\"Jason N Mehta, Brianna E Morales, John H Rossmeisl, Waldemar Debinski, Christopher G Rylander\",\"doi\":\"10.1115/1.4055607\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Convection-enhanced delivery (CED) is a drug delivery technique used to deliver therapeutics directly to the brain and is a continually evolving technique to treat glioblastoma. Early versions of CED have proven to result in inadequate drug volume dispersed (V<sub>d</sub>), increasing the likelihood of tumor recurrence. Fiber optic microneedle devices (FMDs) with the ability to deliver fluid and thermal energy simultaneously have shown an ability to increase V<sub>d</sub>, but FMDs have historically had low light transmission efficiency. In this study, we present a new fabrication method, solid fiber inside capillary (SFIC) FMD, and a modified fusion splicing (FS) method with the goal of increasing light delivery efficiency. The modified FS FMD resulted in an increase in light transmission efficiency between 49% and 173% compared to previous prototypes. However, the FS FMD resulted in significantly lower transmission efficiencies compared to the SFIC FMD (p ≤ 0.04) and FS FMDs perform much worse when light-absorptive materials, like black dye, are placed in the bore. The light absorption of a candidate cytotoxic agent, QUAD-CTX, appear to be similar to water, and light delivery through FS FMDs filled with QUAD-CTX achieves a transmission efficiency of 85.6 ± 5.4%. The fabrication process of the SFIC FMDs results in extremely fragile FMDs. Therefore, the use of a modified FS FMD fabrication process appears to be better suited for balancing the desire to increase light transmission efficiency while retaining a sturdy FMD construction.</p>\",\"PeriodicalId\":49305,\"journal\":{\"name\":\"Journal of Medical Devices-Transactions of the Asme\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.8000,\"publicationDate\":\"2022-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9632479/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Medical Devices-Transactions of the Asme\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1115/1.4055607\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2022/9/27 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Medical Devices-Transactions of the Asme","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1115/1.4055607","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/9/27 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

摘要

对流增强给药(CED)是一种用于将治疗药物直接输送到大脑的药物给药技术,是一种不断发展的治疗胶质母细胞瘤的技术。早期版本的CED已被证明导致药物体积分散(Vd)不足,增加了肿瘤复发的可能性。光纤微针装置(fmd)具有同时输送流体和热能的能力,可以增加Vd,但fmd的透光效率一直很低。在这项研究中,我们提出了一种新的制造方法,固体纤维内毛细管(SFIC) FMD,以及一种改进的融合剪接(FS)方法,目的是提高光传输效率。与之前的原型相比,改进的FS FMD使透光效率提高了49%到173%。然而,与SFIC FMD相比,FS FMD的传输效率显著降低(p≤0.04),并且当孔中放置光吸收材料(如黑色染料)时,FS FMD的传输效率要差得多。候选细胞毒剂QUAD-CTX的光吸收与水相似,光通过填充QUAD-CTX的FS fmd的透射效率为85.6±5.4%。SFIC fmd的制造过程导致fmd非常脆弱。因此,使用改进的FS FMD制造工艺似乎更适合于平衡增加光传输效率的愿望,同时保持坚固的FMD结构。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Solid Fiber Inside of Capillary and Modified Fusion-Spliced Fiber Optic Microneedle Devices for Improved Light Transmission Efficiency.

Convection-enhanced delivery (CED) is a drug delivery technique used to deliver therapeutics directly to the brain and is a continually evolving technique to treat glioblastoma. Early versions of CED have proven to result in inadequate drug volume dispersed (Vd), increasing the likelihood of tumor recurrence. Fiber optic microneedle devices (FMDs) with the ability to deliver fluid and thermal energy simultaneously have shown an ability to increase Vd, but FMDs have historically had low light transmission efficiency. In this study, we present a new fabrication method, solid fiber inside capillary (SFIC) FMD, and a modified fusion splicing (FS) method with the goal of increasing light delivery efficiency. The modified FS FMD resulted in an increase in light transmission efficiency between 49% and 173% compared to previous prototypes. However, the FS FMD resulted in significantly lower transmission efficiencies compared to the SFIC FMD (p ≤ 0.04) and FS FMDs perform much worse when light-absorptive materials, like black dye, are placed in the bore. The light absorption of a candidate cytotoxic agent, QUAD-CTX, appear to be similar to water, and light delivery through FS FMDs filled with QUAD-CTX achieves a transmission efficiency of 85.6 ± 5.4%. The fabrication process of the SFIC FMDs results in extremely fragile FMDs. Therefore, the use of a modified FS FMD fabrication process appears to be better suited for balancing the desire to increase light transmission efficiency while retaining a sturdy FMD construction.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.80
自引率
11.10%
发文量
56
审稿时长
6-12 weeks
期刊介绍: The Journal of Medical Devices presents papers on medical devices that improve diagnostic, interventional and therapeutic treatments focusing on applied research and the development of new medical devices or instrumentation. It provides special coverage of novel devices that allow new surgical strategies, new methods of drug delivery, or possible reductions in the complexity, cost, or adverse results of health care. The Design Innovation category features papers focusing on novel devices, including papers with limited clinical or engineering results. The Medical Device News section provides coverage of advances, trends, and events.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信