肩峰和肩胛骨冠突同侧骨折

IF 1.8 4区 医学 Q2 ORTHOPEDICS
Yusuf Omar Qalib , Srinivasa Reddy Medagam , Sunil Dachepalli
{"title":"肩峰和肩胛骨冠突同侧骨折","authors":"Yusuf Omar Qalib ,&nbsp;Srinivasa Reddy Medagam ,&nbsp;Sunil Dachepalli","doi":"10.1016/j.cjtee.2023.04.003","DOIUrl":null,"url":null,"abstract":"<div><p>A fracture of the acromion and coracoid processes of scapula is rarely seen in the outpatient clinic, due to the acromion's anatomical position and shape, as well as the strong ligaments and muscles that are attached to it. These fractures are caused by either direct or indirect high-energy trauma injuries to the shoulder joint, leading to severe pain and a grossly restricted range of motion. Several acromial classifications were reported, but this type of longitudinal plane fracture of the acromion process in our case is yet to be described in the current literature. We present a rare combination of the coracoid process and unstable acromion bony projection fractures that have not previously been noted for this type of fracture. The closest to this is Kuhn's type III classification. A 51-year-old male presented to our emergency department complaining of the right shoulder pain and difficulty raising his arm following a 2-wheeler accident. The patient was managed by open reduction and internal fixation with 3 cannulated cancellous screws fixation and progressed well with no postoperative complications. He was asymptomatic postoperatively and regained full range of motion after 4 months.</p></div>","PeriodicalId":51555,"journal":{"name":"Chinese Journal of Traumatology","volume":"27 2","pages":"Pages 121-124"},"PeriodicalIF":1.8000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S1008127523000275/pdfft?md5=1e15aac75fc4d8ed21863720fcb2d26e&pid=1-s2.0-S1008127523000275-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Ipsilateral fractures of the acromion and coracoid processes of the scapula\",\"authors\":\"Yusuf Omar Qalib ,&nbsp;Srinivasa Reddy Medagam ,&nbsp;Sunil Dachepalli\",\"doi\":\"10.1016/j.cjtee.2023.04.003\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>A fracture of the acromion and coracoid processes of scapula is rarely seen in the outpatient clinic, due to the acromion's anatomical position and shape, as well as the strong ligaments and muscles that are attached to it. These fractures are caused by either direct or indirect high-energy trauma injuries to the shoulder joint, leading to severe pain and a grossly restricted range of motion. Several acromial classifications were reported, but this type of longitudinal plane fracture of the acromion process in our case is yet to be described in the current literature. We present a rare combination of the coracoid process and unstable acromion bony projection fractures that have not previously been noted for this type of fracture. The closest to this is Kuhn's type III classification. A 51-year-old male presented to our emergency department complaining of the right shoulder pain and difficulty raising his arm following a 2-wheeler accident. The patient was managed by open reduction and internal fixation with 3 cannulated cancellous screws fixation and progressed well with no postoperative complications. He was asymptomatic postoperatively and regained full range of motion after 4 months.</p></div>\",\"PeriodicalId\":51555,\"journal\":{\"name\":\"Chinese Journal of Traumatology\",\"volume\":\"27 2\",\"pages\":\"Pages 121-124\"},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2024-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S1008127523000275/pdfft?md5=1e15aac75fc4d8ed21863720fcb2d26e&pid=1-s2.0-S1008127523000275-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Chinese Journal of Traumatology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1008127523000275\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Chinese Journal of Traumatology","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1008127523000275","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

摘要

肩峰和肩胛骨冠突骨折在门诊中很少见,这是由于肩峰的解剖位置和形状,以及与之相连的强大韧带和肌肉所致。这些骨折是由于肩关节受到直接或间接的高能量创伤造成的,会导致剧烈疼痛和活动范围严重受限。有报道称肩峰有多种分类,但我们病例中的肩峰突纵向平面骨折类型在目前的文献中尚未见描述。我们的病例是一种罕见的肩峰突和不稳定肩峰骨质投影骨折的组合,这种类型的骨折以前从未报道过。与此最接近的是库恩的 III 型分类。一名 51 岁的男性患者在一次两轮摩托车事故后到我院急诊科就诊,主诉右肩疼痛,手臂抬起困难。患者接受了切开复位内固定术,并用3枚插管松质骨螺钉固定,术后进展顺利,未出现并发症。术后无症状,4 个月后恢复了完全活动范围。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Ipsilateral fractures of the acromion and coracoid processes of the scapula

A fracture of the acromion and coracoid processes of scapula is rarely seen in the outpatient clinic, due to the acromion's anatomical position and shape, as well as the strong ligaments and muscles that are attached to it. These fractures are caused by either direct or indirect high-energy trauma injuries to the shoulder joint, leading to severe pain and a grossly restricted range of motion. Several acromial classifications were reported, but this type of longitudinal plane fracture of the acromion process in our case is yet to be described in the current literature. We present a rare combination of the coracoid process and unstable acromion bony projection fractures that have not previously been noted for this type of fracture. The closest to this is Kuhn's type III classification. A 51-year-old male presented to our emergency department complaining of the right shoulder pain and difficulty raising his arm following a 2-wheeler accident. The patient was managed by open reduction and internal fixation with 3 cannulated cancellous screws fixation and progressed well with no postoperative complications. He was asymptomatic postoperatively and regained full range of motion after 4 months.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.80
自引率
4.80%
发文量
1707
审稿时长
28 weeks
期刊介绍: Chinese Journal of Traumatology (CJT, ISSN 1008-1275) was launched in 1998 and is a peer-reviewed English journal authorized by Chinese Association of Trauma, Chinese Medical Association. It is multidisciplinary and designed to provide the most current and relevant information for both the clinical and basic research in the field of traumatic medicine. CJT primarily publishes expert forums, original papers, case reports and so on. Topics cover trauma system and management, surgical procedures, acute care, rehabilitation, post-traumatic complications, translational medicine, traffic medicine and other related areas. The journal especially emphasizes clinical application, technique, surgical video, guideline, recommendations for more effective surgical approaches.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信