{"title":"呼气分析中取样成分对挥发物的排放和吸收。","authors":"Y Lan Pham, Olaf Holz, Jonathan D Beauchamp","doi":"10.1088/1752-7163/acce34","DOIUrl":null,"url":null,"abstract":"<p><p>The first and most crucial step in breath research is adequate sampling, which plays a pivotal role in quality assurance of breath datasets. In particular, the emissions or uptake of volatile organic compounds (VOCs) by sampling interface materials present a risk of disrupting breath gas samples. This study investigated emissions and uptake by three interface components, namely a silicon facemask, a reusable 3D-printed mouthpiece adapter, and a pulmonary function test filter compatible with the commercial Respiration Collector for<i>In-Vitro</i>Analysis (ReCIVA) breath sampling device. Emissions were examined before and after (hydro-)thermal treatment of the components, and uptake was assessed by exposing each material to 12 representative breath VOCs comprising alcohols, aldehydes, ketones, carboxylic acids, terpenes, sulphurous and nitrogenous compounds at different target concentration ranges (∼10 ppb<sub>V</sub>and ∼100 ppb<sub>V</sub>). Chemical analyses of VOCs were performed using proton transfer reaction-time-of-flight-mass spectrometry (PTR-TOFMS) with supporting analyses via thermal desorption comprehensive two-dimensional gas chromatography-TOFMS (TD-GC×GC-TOFMS). The filter exhibited the lowest overall emissions compared to the mask or adapter, which both had equivalently high emissions (albeit for different compounds). Treatment of the materials reduced the total VOC emissions by 62% in the mask, 89% in the filter and 99% in the adapter. Uptakes of compounds were lowest for the adapter and most pronounced in the mask. In particular, 1-butanol, acetone, 2-butanone, 1,8-cineole and dimethyl sulphide showed negligible uptake across all materials, whereas ethanol, nonanal, acetic acid, butanoic acid, limonene and indole exhibited marked losses. Knowledge of emissions and/or uptake by sampling components is key to reducing the likelihood of erroneous data interpretation, ultimately expediting progress in the field of breath test development.</p>","PeriodicalId":15306,"journal":{"name":"Journal of breath research","volume":"17 3","pages":""},"PeriodicalIF":3.7000,"publicationDate":"2023-05-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Emissions and uptake of volatiles by sampling components in breath analysis.\",\"authors\":\"Y Lan Pham, Olaf Holz, Jonathan D Beauchamp\",\"doi\":\"10.1088/1752-7163/acce34\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The first and most crucial step in breath research is adequate sampling, which plays a pivotal role in quality assurance of breath datasets. In particular, the emissions or uptake of volatile organic compounds (VOCs) by sampling interface materials present a risk of disrupting breath gas samples. This study investigated emissions and uptake by three interface components, namely a silicon facemask, a reusable 3D-printed mouthpiece adapter, and a pulmonary function test filter compatible with the commercial Respiration Collector for<i>In-Vitro</i>Analysis (ReCIVA) breath sampling device. Emissions were examined before and after (hydro-)thermal treatment of the components, and uptake was assessed by exposing each material to 12 representative breath VOCs comprising alcohols, aldehydes, ketones, carboxylic acids, terpenes, sulphurous and nitrogenous compounds at different target concentration ranges (∼10 ppb<sub>V</sub>and ∼100 ppb<sub>V</sub>). Chemical analyses of VOCs were performed using proton transfer reaction-time-of-flight-mass spectrometry (PTR-TOFMS) with supporting analyses via thermal desorption comprehensive two-dimensional gas chromatography-TOFMS (TD-GC×GC-TOFMS). The filter exhibited the lowest overall emissions compared to the mask or adapter, which both had equivalently high emissions (albeit for different compounds). Treatment of the materials reduced the total VOC emissions by 62% in the mask, 89% in the filter and 99% in the adapter. Uptakes of compounds were lowest for the adapter and most pronounced in the mask. In particular, 1-butanol, acetone, 2-butanone, 1,8-cineole and dimethyl sulphide showed negligible uptake across all materials, whereas ethanol, nonanal, acetic acid, butanoic acid, limonene and indole exhibited marked losses. Knowledge of emissions and/or uptake by sampling components is key to reducing the likelihood of erroneous data interpretation, ultimately expediting progress in the field of breath test development.</p>\",\"PeriodicalId\":15306,\"journal\":{\"name\":\"Journal of breath research\",\"volume\":\"17 3\",\"pages\":\"\"},\"PeriodicalIF\":3.7000,\"publicationDate\":\"2023-05-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of breath research\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1088/1752-7163/acce34\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"BIOCHEMICAL RESEARCH METHODS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of breath research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1088/1752-7163/acce34","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
Emissions and uptake of volatiles by sampling components in breath analysis.
The first and most crucial step in breath research is adequate sampling, which plays a pivotal role in quality assurance of breath datasets. In particular, the emissions or uptake of volatile organic compounds (VOCs) by sampling interface materials present a risk of disrupting breath gas samples. This study investigated emissions and uptake by three interface components, namely a silicon facemask, a reusable 3D-printed mouthpiece adapter, and a pulmonary function test filter compatible with the commercial Respiration Collector forIn-VitroAnalysis (ReCIVA) breath sampling device. Emissions were examined before and after (hydro-)thermal treatment of the components, and uptake was assessed by exposing each material to 12 representative breath VOCs comprising alcohols, aldehydes, ketones, carboxylic acids, terpenes, sulphurous and nitrogenous compounds at different target concentration ranges (∼10 ppbVand ∼100 ppbV). Chemical analyses of VOCs were performed using proton transfer reaction-time-of-flight-mass spectrometry (PTR-TOFMS) with supporting analyses via thermal desorption comprehensive two-dimensional gas chromatography-TOFMS (TD-GC×GC-TOFMS). The filter exhibited the lowest overall emissions compared to the mask or adapter, which both had equivalently high emissions (albeit for different compounds). Treatment of the materials reduced the total VOC emissions by 62% in the mask, 89% in the filter and 99% in the adapter. Uptakes of compounds were lowest for the adapter and most pronounced in the mask. In particular, 1-butanol, acetone, 2-butanone, 1,8-cineole and dimethyl sulphide showed negligible uptake across all materials, whereas ethanol, nonanal, acetic acid, butanoic acid, limonene and indole exhibited marked losses. Knowledge of emissions and/or uptake by sampling components is key to reducing the likelihood of erroneous data interpretation, ultimately expediting progress in the field of breath test development.
期刊介绍:
Journal of Breath Research is dedicated to all aspects of scientific breath research. The traditional focus is on analysis of volatile compounds and aerosols in exhaled breath for the investigation of exogenous exposures, metabolism, toxicology, health status and the diagnosis of disease and breath odours. The journal also welcomes other breath-related topics.
Typical areas of interest include:
Big laboratory instrumentation: describing new state-of-the-art analytical instrumentation capable of performing high-resolution discovery and targeted breath research; exploiting complex technologies drawn from other areas of biochemistry and genetics for breath research.
Engineering solutions: developing new breath sampling technologies for condensate and aerosols, for chemical and optical sensors, for extraction and sample preparation methods, for automation and standardization, and for multiplex analyses to preserve the breath matrix and facilitating analytical throughput. Measure exhaled constituents (e.g. CO2, acetone, isoprene) as markers of human presence or mitigate such contaminants in enclosed environments.
Human and animal in vivo studies: decoding the ''breath exposome'', implementing exposure and intervention studies, performing cross-sectional and case-control research, assaying immune and inflammatory response, and testing mammalian host response to infections and exogenous exposures to develop information directly applicable to systems biology. Studying inhalation toxicology; inhaled breath as a source of internal dose; resultant blood, breath and urinary biomarkers linked to inhalation pathway.
Cellular and molecular level in vitro studies.
Clinical, pharmacological and forensic applications.