大鼠7 T MRI用开槽端环体积线圈的理论与实验研究。

IF 2 4区 医学 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Sergio Solis-Najera, Rodrigo Ruiz, Rodrigo Martin, Fabian Vazquez, Oscar Marrufo, Alfredo Odon Rodriguez
{"title":"大鼠7 T MRI用开槽端环体积线圈的理论与实验研究。","authors":"Sergio Solis-Najera, Rodrigo Ruiz, Rodrigo Martin, Fabian Vazquez, Oscar Marrufo, Alfredo Odon Rodriguez","doi":"10.1007/s10334-023-01096-w","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>A volume coil with squared slots-end ring was developed to attain improved sensitivity for imaging of rat's brain at 7 T.</p><p><strong>Material and methods: </strong>The principles of the high cavity resonator for the low-pass case and the law of Biot-Savart were used to derive a theoretical expression of [Formula: see text]. The slotted-end ring resonator showed a theoretical 2.22-fold sensitivity improvement over the standard birdcage coil with similar dimensions. Numerical studies were carried out for the electromagnetic fields and specific absorption rates for our coil and a birdcage coil loaded with a saline-filled spherical phantom and a digital brain of a rat.</p><p><strong>Results: </strong>An improvement of the signal-to-noise ratio (SNR) can be observed for the slotted volume coil over the birdcage regardless of the load used in the electromagnetic simulations. The specific absorption rate simulations show a decrement for the digital brain and quite similar values with the saline solution phantom. Phantom and rat's brain images were acquired at 7 T to prove the viability of the coil design. The experimental noise figure of our coil design was four times less than the standard birdcage with similar dimensions, which showed a 44.5% increase in experimental SNR.</p><p><strong>Discussion: </strong>There is remarkable agreement among the theoretical, numerical and experimental sensitivity values, which all demonstrate that the coil performance for MR imaging of small rodents can be improved using slotted end-rings.</p>","PeriodicalId":18067,"journal":{"name":"Magnetic Resonance Materials in Physics, Biology and Medicine","volume":null,"pages":null},"PeriodicalIF":2.0000,"publicationDate":"2023-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10667404/pdf/","citationCount":"0","resultStr":"{\"title\":\"A theoretical and experimental investigation on a volume coil with slotted end-rings for rat MRI at 7 T.\",\"authors\":\"Sergio Solis-Najera, Rodrigo Ruiz, Rodrigo Martin, Fabian Vazquez, Oscar Marrufo, Alfredo Odon Rodriguez\",\"doi\":\"10.1007/s10334-023-01096-w\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>A volume coil with squared slots-end ring was developed to attain improved sensitivity for imaging of rat's brain at 7 T.</p><p><strong>Material and methods: </strong>The principles of the high cavity resonator for the low-pass case and the law of Biot-Savart were used to derive a theoretical expression of [Formula: see text]. The slotted-end ring resonator showed a theoretical 2.22-fold sensitivity improvement over the standard birdcage coil with similar dimensions. Numerical studies were carried out for the electromagnetic fields and specific absorption rates for our coil and a birdcage coil loaded with a saline-filled spherical phantom and a digital brain of a rat.</p><p><strong>Results: </strong>An improvement of the signal-to-noise ratio (SNR) can be observed for the slotted volume coil over the birdcage regardless of the load used in the electromagnetic simulations. The specific absorption rate simulations show a decrement for the digital brain and quite similar values with the saline solution phantom. Phantom and rat's brain images were acquired at 7 T to prove the viability of the coil design. The experimental noise figure of our coil design was four times less than the standard birdcage with similar dimensions, which showed a 44.5% increase in experimental SNR.</p><p><strong>Discussion: </strong>There is remarkable agreement among the theoretical, numerical and experimental sensitivity values, which all demonstrate that the coil performance for MR imaging of small rodents can be improved using slotted end-rings.</p>\",\"PeriodicalId\":18067,\"journal\":{\"name\":\"Magnetic Resonance Materials in Physics, Biology and Medicine\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.0000,\"publicationDate\":\"2023-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10667404/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Magnetic Resonance Materials in Physics, Biology and Medicine\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s10334-023-01096-w\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/5/15 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Magnetic Resonance Materials in Physics, Biology and Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s10334-023-01096-w","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/5/15 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

目的:研制方形槽端环体积线圈,提高7t大鼠脑成像灵敏度。材料和方法:利用低通情况下的高腔谐振器原理和Biot-Savart定律推导出[公式:见文]的理论表达式。与相似尺寸的标准鸟笼线圈相比,开槽端环谐振器的理论灵敏度提高了2.22倍。我们对我们的线圈和一个装有装满盐水的球形假体和老鼠的数字大脑的鸟笼线圈的电磁场和特定吸收率进行了数值研究。结果:无论电磁模拟中使用的负载如何,鸟笼上的开槽容积线圈都可以提高信噪比。特定吸收率模拟显示,数字大脑的吸收率下降,与生理盐水模型的吸收率非常相似。在7 T时获得幻像和大鼠脑图像,以证明线圈设计的可行性。我们设计的线圈实验噪声系数比同等尺寸的标准鸟笼小4倍,实验信噪比提高44.5%。讨论:在理论,数值和实验灵敏度值之间有显着的一致性,这些值都表明使用开槽端环可以改善小型啮齿动物MR成像线圈的性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

A theoretical and experimental investigation on a volume coil with slotted end-rings for rat MRI at 7 T.

A theoretical and experimental investigation on a volume coil with slotted end-rings for rat MRI at 7 T.

Objective: A volume coil with squared slots-end ring was developed to attain improved sensitivity for imaging of rat's brain at 7 T.

Material and methods: The principles of the high cavity resonator for the low-pass case and the law of Biot-Savart were used to derive a theoretical expression of [Formula: see text]. The slotted-end ring resonator showed a theoretical 2.22-fold sensitivity improvement over the standard birdcage coil with similar dimensions. Numerical studies were carried out for the electromagnetic fields and specific absorption rates for our coil and a birdcage coil loaded with a saline-filled spherical phantom and a digital brain of a rat.

Results: An improvement of the signal-to-noise ratio (SNR) can be observed for the slotted volume coil over the birdcage regardless of the load used in the electromagnetic simulations. The specific absorption rate simulations show a decrement for the digital brain and quite similar values with the saline solution phantom. Phantom and rat's brain images were acquired at 7 T to prove the viability of the coil design. The experimental noise figure of our coil design was four times less than the standard birdcage with similar dimensions, which showed a 44.5% increase in experimental SNR.

Discussion: There is remarkable agreement among the theoretical, numerical and experimental sensitivity values, which all demonstrate that the coil performance for MR imaging of small rodents can be improved using slotted end-rings.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.60
自引率
0.00%
发文量
58
审稿时长
>12 weeks
期刊介绍: MAGMA is a multidisciplinary international journal devoted to the publication of articles on all aspects of magnetic resonance techniques and their applications in medicine and biology. MAGMA currently publishes research papers, reviews, letters to the editor, and commentaries, six times a year. The subject areas covered by MAGMA include: advances in materials, hardware and software in magnetic resonance technology, new developments and results in research and practical applications of magnetic resonance imaging and spectroscopy related to biology and medicine, study of animal models and intact cells using magnetic resonance, reports of clinical trials on humans and clinical validation of magnetic resonance protocols.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信