Marta Álvarez Nadal, Nuria Rodríguez Mendiola, Martha Elizabeth Díaz Domínguez, Milagros Fernández Lucas
{"title":"单独调节绝对血容量反馈控制:一个有希望的解决方案,为透析性低血压","authors":"Marta Álvarez Nadal, Nuria Rodríguez Mendiola, Martha Elizabeth Díaz Domínguez, Milagros Fernández Lucas","doi":"10.1111/hdi.13074","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Introduction</h3>\n \n <p>Intradialytic hypotension (IDH) remains one of the most frequent complications associated to hemodialysis (HD), frequently triggered by a reduction in absolute blood volume (ABV) not compensated by vascular refilling. A recently developed dilutional method allows routinary measurement of ABV and, by a simple algorithm, may turn blood volume monitor (BVM) guided UF (ultrafiltration) biofeedback into an ABV control, automatically adjusting UF rate to maintain ABV above a preset threshold. The aim of this study is to identify an individual critical ABV threshold and test the ability of an ABV feedback control to avoid IDH.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>We studied 24 patients throughout three consecutive midweek HD treatments. ABV and blood pressure (BP) were measured every 30 min and anytime the patient referred any symptoms to identify each patient's critical ABV (ABV at the time of hypotension). A fixed bolus dilution approach at the start of HD was used to calculate ABV. Then, patients were followed through three additional HD treatments and IDH development was analyzed.</p>\n </section>\n \n <section>\n \n <h3> Findings</h3>\n \n <p>Seventy-one treatments performed in 24 patients. ABV monitoring showed a constant decrease as HD treatment progressed. Thirteen IDH events were observed in eight different patients, with a mean systolic BP drop in IDH treatments of 37.38 ± 4.31 mmHg and a mean adjusted ABV at hypotension of 71.07 ± 14.88 mL/kg. Critical ABV was individually set in patients prone to IDH. As expected, ABV feedback control successfully maintained ABV over preset critical ABV. IDH events were avoided in 21 out of 22 treatments performed. ABV drop was successfully reduced, as well as SBP drop (despite similar UF than prior to ABV feedback control implementation).</p>\n </section>\n \n <section>\n \n <h3> Discussion</h3>\n \n <p>ABV feedback control avoided IDH in 21 out of 22 treatments performed by maintaining blood volume above critical ABV, significantly reducing ABV variations without compromising prescribed UF.</p>\n </section>\n </div>","PeriodicalId":12815,"journal":{"name":"Hemodialysis International","volume":"27 2","pages":"184-192"},"PeriodicalIF":1.2000,"publicationDate":"2023-02-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Individually adjusted absolute blood volume feedback control: A promising solution for intradialytic hypotension\",\"authors\":\"Marta Álvarez Nadal, Nuria Rodríguez Mendiola, Martha Elizabeth Díaz Domínguez, Milagros Fernández Lucas\",\"doi\":\"10.1111/hdi.13074\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n \\n <section>\\n \\n <h3> Introduction</h3>\\n \\n <p>Intradialytic hypotension (IDH) remains one of the most frequent complications associated to hemodialysis (HD), frequently triggered by a reduction in absolute blood volume (ABV) not compensated by vascular refilling. A recently developed dilutional method allows routinary measurement of ABV and, by a simple algorithm, may turn blood volume monitor (BVM) guided UF (ultrafiltration) biofeedback into an ABV control, automatically adjusting UF rate to maintain ABV above a preset threshold. The aim of this study is to identify an individual critical ABV threshold and test the ability of an ABV feedback control to avoid IDH.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Methods</h3>\\n \\n <p>We studied 24 patients throughout three consecutive midweek HD treatments. ABV and blood pressure (BP) were measured every 30 min and anytime the patient referred any symptoms to identify each patient's critical ABV (ABV at the time of hypotension). A fixed bolus dilution approach at the start of HD was used to calculate ABV. Then, patients were followed through three additional HD treatments and IDH development was analyzed.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Findings</h3>\\n \\n <p>Seventy-one treatments performed in 24 patients. ABV monitoring showed a constant decrease as HD treatment progressed. Thirteen IDH events were observed in eight different patients, with a mean systolic BP drop in IDH treatments of 37.38 ± 4.31 mmHg and a mean adjusted ABV at hypotension of 71.07 ± 14.88 mL/kg. Critical ABV was individually set in patients prone to IDH. As expected, ABV feedback control successfully maintained ABV over preset critical ABV. IDH events were avoided in 21 out of 22 treatments performed. ABV drop was successfully reduced, as well as SBP drop (despite similar UF than prior to ABV feedback control implementation).</p>\\n </section>\\n \\n <section>\\n \\n <h3> Discussion</h3>\\n \\n <p>ABV feedback control avoided IDH in 21 out of 22 treatments performed by maintaining blood volume above critical ABV, significantly reducing ABV variations without compromising prescribed UF.</p>\\n </section>\\n </div>\",\"PeriodicalId\":12815,\"journal\":{\"name\":\"Hemodialysis International\",\"volume\":\"27 2\",\"pages\":\"184-192\"},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2023-02-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Hemodialysis International\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1111/hdi.13074\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"UROLOGY & NEPHROLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Hemodialysis International","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/hdi.13074","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"UROLOGY & NEPHROLOGY","Score":null,"Total":0}
Individually adjusted absolute blood volume feedback control: A promising solution for intradialytic hypotension
Introduction
Intradialytic hypotension (IDH) remains one of the most frequent complications associated to hemodialysis (HD), frequently triggered by a reduction in absolute blood volume (ABV) not compensated by vascular refilling. A recently developed dilutional method allows routinary measurement of ABV and, by a simple algorithm, may turn blood volume monitor (BVM) guided UF (ultrafiltration) biofeedback into an ABV control, automatically adjusting UF rate to maintain ABV above a preset threshold. The aim of this study is to identify an individual critical ABV threshold and test the ability of an ABV feedback control to avoid IDH.
Methods
We studied 24 patients throughout three consecutive midweek HD treatments. ABV and blood pressure (BP) were measured every 30 min and anytime the patient referred any symptoms to identify each patient's critical ABV (ABV at the time of hypotension). A fixed bolus dilution approach at the start of HD was used to calculate ABV. Then, patients were followed through three additional HD treatments and IDH development was analyzed.
Findings
Seventy-one treatments performed in 24 patients. ABV monitoring showed a constant decrease as HD treatment progressed. Thirteen IDH events were observed in eight different patients, with a mean systolic BP drop in IDH treatments of 37.38 ± 4.31 mmHg and a mean adjusted ABV at hypotension of 71.07 ± 14.88 mL/kg. Critical ABV was individually set in patients prone to IDH. As expected, ABV feedback control successfully maintained ABV over preset critical ABV. IDH events were avoided in 21 out of 22 treatments performed. ABV drop was successfully reduced, as well as SBP drop (despite similar UF than prior to ABV feedback control implementation).
Discussion
ABV feedback control avoided IDH in 21 out of 22 treatments performed by maintaining blood volume above critical ABV, significantly reducing ABV variations without compromising prescribed UF.
期刊介绍:
Hemodialysis International was originally an annual publication containing the Proceedings of the International Symposium on Hemodialysis held in conjunction with the Annual Dialysis Conference. Since 2003, Hemodialysis International is published quarterly and contains original papers on clinical and experimental topics related to dialysis in addition to the Annual Dialysis Conference supplement. This journal is a must-have for nephrologists, nurses, and technicians worldwide. Quarterly issues of Hemodialysis International are included with your membership to the International Society for Hemodialysis.
The journal contains original articles, review articles, and commentary to keep readers completely updated in the field of hemodialysis. Edited by international and multidisciplinary experts, Hemodialysis International disseminates critical information in the field.