自动颅内血管标记与学习促进血管连接,半径和空间背景。

Jannik Sobisch, Žiga Bizjak, Aichi Chien, Žiga Špiclin
{"title":"自动颅内血管标记与学习促进血管连接,半径和空间背景。","authors":"Jannik Sobisch,&nbsp;Žiga Bizjak,&nbsp;Aichi Chien,&nbsp;Žiga Špiclin","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Cerebrovascular diseases are among the world's top causes of death and their screening and diagnosis rely on angiographic imaging. We focused on automated anatomical labeling of cerebral arteries that enables their cross-sectional quantification and inter-subject comparisons and thereby identification of geometric risk factors correlated to the cerebrovascular diseases. We used 152 cerebral TOF-MRA angiograms from three publicly available datasets and manually created reference labeling using Slicer3D. We extracted centerlines from nnU-net based segmentations using VesselVio and labeled them according to the reference labeling. Vessel centerline coordinates, in combination with additional vessel connectivity, radius and spatial context features were used for training seven distinct PointNet++ models. Model trained solely on the vessel centerline coordinates resulted in ACC of 0.93 and across-labels average TPR was 0.88. Including vessel radius significantly improved ACC to 0.95, and average TPR to 0.91. Finally, focusing spatial context to the Circle of Willis are resulted in best ACC of 0.96 and best average TPR of 0.93. Hence, using vessel radius and spatial context greatly improved vessel labeling, with the attained perfomance opening the avenue for clinical applications of intracranial vessel labeling.</p>","PeriodicalId":74504,"journal":{"name":"Proceedings of machine learning research","volume":"194 ","pages":"34-44"},"PeriodicalIF":0.0000,"publicationDate":"2022-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10112880/pdf/nihms-1889674.pdf","citationCount":"0","resultStr":"{\"title\":\"Automated intracranial vessel labeling with learning boosted by vessel connectivity, radii and spatial context.\",\"authors\":\"Jannik Sobisch,&nbsp;Žiga Bizjak,&nbsp;Aichi Chien,&nbsp;Žiga Špiclin\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Cerebrovascular diseases are among the world's top causes of death and their screening and diagnosis rely on angiographic imaging. We focused on automated anatomical labeling of cerebral arteries that enables their cross-sectional quantification and inter-subject comparisons and thereby identification of geometric risk factors correlated to the cerebrovascular diseases. We used 152 cerebral TOF-MRA angiograms from three publicly available datasets and manually created reference labeling using Slicer3D. We extracted centerlines from nnU-net based segmentations using VesselVio and labeled them according to the reference labeling. Vessel centerline coordinates, in combination with additional vessel connectivity, radius and spatial context features were used for training seven distinct PointNet++ models. Model trained solely on the vessel centerline coordinates resulted in ACC of 0.93 and across-labels average TPR was 0.88. Including vessel radius significantly improved ACC to 0.95, and average TPR to 0.91. Finally, focusing spatial context to the Circle of Willis are resulted in best ACC of 0.96 and best average TPR of 0.93. Hence, using vessel radius and spatial context greatly improved vessel labeling, with the attained perfomance opening the avenue for clinical applications of intracranial vessel labeling.</p>\",\"PeriodicalId\":74504,\"journal\":{\"name\":\"Proceedings of machine learning research\",\"volume\":\"194 \",\"pages\":\"34-44\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10112880/pdf/nihms-1889674.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of machine learning research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of machine learning research","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

脑血管疾病是世界上最主要的死亡原因之一,其筛查和诊断依赖于血管造影成像。我们专注于脑动脉的自动解剖标记,使其横断面量化和受试者间比较成为可能,从而确定与脑血管疾病相关的几何危险因素。我们使用了来自三个公开数据集的152张大脑TOF-MRA血管图,并使用Slicer3D手动创建了参考标签。我们使用VesselVio从基于nnU-net的分割中提取中心线,并根据参考标记对其进行标记。船舶中心线坐标,结合额外的船舶连通性、半径和空间环境特征,用于训练七种不同的PointNet++模型。仅在血管中心线坐标上训练的模型ACC为0.93,跨标签平均TPR为0.88。加入血管半径后,ACC显著提高至0.95,TPR显著提高至0.91。最后,将空间背景聚焦于威利斯圈的最佳ACC值为0.96,最佳平均TPR值为0.93。因此,利用血管半径和空间背景极大地改善了血管标记,所获得的性能为颅内血管标记的临床应用开辟了道路。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Automated intracranial vessel labeling with learning boosted by vessel connectivity, radii and spatial context.

Cerebrovascular diseases are among the world's top causes of death and their screening and diagnosis rely on angiographic imaging. We focused on automated anatomical labeling of cerebral arteries that enables their cross-sectional quantification and inter-subject comparisons and thereby identification of geometric risk factors correlated to the cerebrovascular diseases. We used 152 cerebral TOF-MRA angiograms from three publicly available datasets and manually created reference labeling using Slicer3D. We extracted centerlines from nnU-net based segmentations using VesselVio and labeled them according to the reference labeling. Vessel centerline coordinates, in combination with additional vessel connectivity, radius and spatial context features were used for training seven distinct PointNet++ models. Model trained solely on the vessel centerline coordinates resulted in ACC of 0.93 and across-labels average TPR was 0.88. Including vessel radius significantly improved ACC to 0.95, and average TPR to 0.91. Finally, focusing spatial context to the Circle of Willis are resulted in best ACC of 0.96 and best average TPR of 0.93. Hence, using vessel radius and spatial context greatly improved vessel labeling, with the attained perfomance opening the avenue for clinical applications of intracranial vessel labeling.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信