{"title":"输血依赖性地中海贫血中铁超载的优化血清铁蛋白预测:似然比和年龄调整方法。","authors":"Lutfi Ali Kurban, Bashayer Khamis Almarri, Maitha Helal Alshamsi, Shahid Shehadeh Abdelrahman, Sara Ghumail Alwahshi, Qays Alhorani, Rizwan Syed, Omran Bakoush","doi":"10.5144/0256-4947.2023.90","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Early detection of iron overload in transfusion-dependent thalassemia (TDT) patients is critical to prevent complications and improve survival.</p><p><strong>Objectives: </strong>Evaluate the utility of serum ferritin (SF) in the prediction of hepatic and myocardial iron overload (HIO and MIO) compared to T2*-MRI.</p><p><strong>Design: </strong>Retrospective SETTINGS: Governmental hospitals.</p><p><strong>Patients and methods: </strong>Patients with TDT who had T2*-MRI examinations between January 2016 to October 2019 were included. The predictive value of SF for detection of HIO and MIO was assessed by measuring area under the curve (AUC). A sample size of 123 cases was calculated to detect a correlation of 0.25 with 90% power and a two-sided type I error of 0.05.</p><p><strong>Main outcome measures: </strong>The correlation between SF and estimated hepatic iron concentration.</p><p><strong>Sample size: </strong>137 TDT patients who required regular blood transfusions.</p><p><strong>Results: </strong>The predictive value of SF was excellent for detection of HIO (AUC=0.83-0.87) but fair for detection of MIO (AUC=0.67). The two independent predictors of MIO were age and SF. The log of (age × SF) enhanced the SF predictive value for MIO (AUC=0.78). SF values of 700 and 1250 mg/L effectively excluded mild and moderate HIO with a sensitivity of 97.8% and 94.2%, respectively (LR-=0.1). While SF values of 1640 and 2150 mg/L accurately diagnosed mild and moderate HIO with a specificity of 95.55% and 96.4%, respectively (LR+>10). A log of (age × SF) cut-off value of 4.15 effectively excluded MIO (LR-=0.1), while a value of 4.65 moderately confirmed MIO (LR+=3.2).</p><p><strong>Conclusions: </strong>SF is an excellent predictor of hepatic IO in TDT. Age adjustment enhanced its myocardial IO predictive accuracy. Likelihood ratio-based SF cut-off values may help clinicians in risk stratification and treatment decision-making.</p><p><strong>Limitations: </strong>The laboratory data were gathered retrospectively and although the risk of selection bias for T2*-MRI examination is thought to be low, it cannot be ignored.</p><p><strong>Conflict of interest: </strong>None.</p>","PeriodicalId":8016,"journal":{"name":"Annals of Saudi Medicine","volume":null,"pages":null},"PeriodicalIF":1.5000,"publicationDate":"2023-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/14/a2/0256-4947.2023.90.PMC10082945.pdf","citationCount":"0","resultStr":"{\"title\":\"Optimized serum ferritin prediction of iron overload in transfusion-dependent thalassemia: likelihood ratio and age-adjustment approach.\",\"authors\":\"Lutfi Ali Kurban, Bashayer Khamis Almarri, Maitha Helal Alshamsi, Shahid Shehadeh Abdelrahman, Sara Ghumail Alwahshi, Qays Alhorani, Rizwan Syed, Omran Bakoush\",\"doi\":\"10.5144/0256-4947.2023.90\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Early detection of iron overload in transfusion-dependent thalassemia (TDT) patients is critical to prevent complications and improve survival.</p><p><strong>Objectives: </strong>Evaluate the utility of serum ferritin (SF) in the prediction of hepatic and myocardial iron overload (HIO and MIO) compared to T2*-MRI.</p><p><strong>Design: </strong>Retrospective SETTINGS: Governmental hospitals.</p><p><strong>Patients and methods: </strong>Patients with TDT who had T2*-MRI examinations between January 2016 to October 2019 were included. The predictive value of SF for detection of HIO and MIO was assessed by measuring area under the curve (AUC). A sample size of 123 cases was calculated to detect a correlation of 0.25 with 90% power and a two-sided type I error of 0.05.</p><p><strong>Main outcome measures: </strong>The correlation between SF and estimated hepatic iron concentration.</p><p><strong>Sample size: </strong>137 TDT patients who required regular blood transfusions.</p><p><strong>Results: </strong>The predictive value of SF was excellent for detection of HIO (AUC=0.83-0.87) but fair for detection of MIO (AUC=0.67). The two independent predictors of MIO were age and SF. The log of (age × SF) enhanced the SF predictive value for MIO (AUC=0.78). SF values of 700 and 1250 mg/L effectively excluded mild and moderate HIO with a sensitivity of 97.8% and 94.2%, respectively (LR-=0.1). While SF values of 1640 and 2150 mg/L accurately diagnosed mild and moderate HIO with a specificity of 95.55% and 96.4%, respectively (LR+>10). A log of (age × SF) cut-off value of 4.15 effectively excluded MIO (LR-=0.1), while a value of 4.65 moderately confirmed MIO (LR+=3.2).</p><p><strong>Conclusions: </strong>SF is an excellent predictor of hepatic IO in TDT. Age adjustment enhanced its myocardial IO predictive accuracy. Likelihood ratio-based SF cut-off values may help clinicians in risk stratification and treatment decision-making.</p><p><strong>Limitations: </strong>The laboratory data were gathered retrospectively and although the risk of selection bias for T2*-MRI examination is thought to be low, it cannot be ignored.</p><p><strong>Conflict of interest: </strong>None.</p>\",\"PeriodicalId\":8016,\"journal\":{\"name\":\"Annals of Saudi Medicine\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2023-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/14/a2/0256-4947.2023.90.PMC10082945.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Annals of Saudi Medicine\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.5144/0256-4947.2023.90\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"MEDICINE, GENERAL & INTERNAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of Saudi Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.5144/0256-4947.2023.90","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
Optimized serum ferritin prediction of iron overload in transfusion-dependent thalassemia: likelihood ratio and age-adjustment approach.
Background: Early detection of iron overload in transfusion-dependent thalassemia (TDT) patients is critical to prevent complications and improve survival.
Objectives: Evaluate the utility of serum ferritin (SF) in the prediction of hepatic and myocardial iron overload (HIO and MIO) compared to T2*-MRI.
Patients and methods: Patients with TDT who had T2*-MRI examinations between January 2016 to October 2019 were included. The predictive value of SF for detection of HIO and MIO was assessed by measuring area under the curve (AUC). A sample size of 123 cases was calculated to detect a correlation of 0.25 with 90% power and a two-sided type I error of 0.05.
Main outcome measures: The correlation between SF and estimated hepatic iron concentration.
Sample size: 137 TDT patients who required regular blood transfusions.
Results: The predictive value of SF was excellent for detection of HIO (AUC=0.83-0.87) but fair for detection of MIO (AUC=0.67). The two independent predictors of MIO were age and SF. The log of (age × SF) enhanced the SF predictive value for MIO (AUC=0.78). SF values of 700 and 1250 mg/L effectively excluded mild and moderate HIO with a sensitivity of 97.8% and 94.2%, respectively (LR-=0.1). While SF values of 1640 and 2150 mg/L accurately diagnosed mild and moderate HIO with a specificity of 95.55% and 96.4%, respectively (LR+>10). A log of (age × SF) cut-off value of 4.15 effectively excluded MIO (LR-=0.1), while a value of 4.65 moderately confirmed MIO (LR+=3.2).
Conclusions: SF is an excellent predictor of hepatic IO in TDT. Age adjustment enhanced its myocardial IO predictive accuracy. Likelihood ratio-based SF cut-off values may help clinicians in risk stratification and treatment decision-making.
Limitations: The laboratory data were gathered retrospectively and although the risk of selection bias for T2*-MRI examination is thought to be low, it cannot be ignored.
期刊介绍:
The Annals of Saudi Medicine (ASM) is published bimonthly by King Faisal Specialist Hospital and Research Centre, Riyadh, Saudi Arabia. We publish scientific reports of clinical interest in English. All submissions are subject to peer review by the editorial board and by reviewers in appropriate specialties. The journal will consider for publication manuscripts from any part of the world, but particularly reports that would be of interest to readers in the Middle East or other parts of Asia and Africa. Please go to the Author Resource Center for additional information.