校准事项:一、声级计基础知识

IF 1.8 3区 医学 Q2 AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY
King Chung
{"title":"校准事项:一、声级计基础知识","authors":"King Chung","doi":"10.1016/j.jcomdis.2022.106300","DOIUrl":null,"url":null,"abstract":"<div><p>Calibration is an essential component of audiology practice to ensure the accuracy of the equipment for audiometric tests and the transferability of test results across different clinics and countries. The ability to check the accuracy of the equipment and the ambient noise levels allows clinicians to monitor the functions of their equipment, to reduce noise distractors in the testing environment, and to have confidence in their test results, especially in humanitarian or field test settings. Sound level meters are the primary instruments to measure the sound pressure levels of the transducers and the test rooms used for audiometric testing. The International Electrotechnical Commission released a 3-part IEC 61672 standard of the specifications of sound level meters in 2013, and it is adopted by the standards organizations of many countries. This first installment of the tutorial series references this international standard and discusses basic acoustics concepts, calibration principles, and key functions of sound level meters in the application of audiometric calibration. Subsequent installments will discuss how to measure the ambient noise levels, how to determine whether a test room is suitable for testing hearing thresholds using different transducers, and how to determine whether different transducers of audiometers meet the national or international standards.</p></div>","PeriodicalId":49175,"journal":{"name":"Journal of Communication Disorders","volume":"101 ","pages":"Article 106300"},"PeriodicalIF":1.8000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Calibration matters: I. Sound level meter basics\",\"authors\":\"King Chung\",\"doi\":\"10.1016/j.jcomdis.2022.106300\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Calibration is an essential component of audiology practice to ensure the accuracy of the equipment for audiometric tests and the transferability of test results across different clinics and countries. The ability to check the accuracy of the equipment and the ambient noise levels allows clinicians to monitor the functions of their equipment, to reduce noise distractors in the testing environment, and to have confidence in their test results, especially in humanitarian or field test settings. Sound level meters are the primary instruments to measure the sound pressure levels of the transducers and the test rooms used for audiometric testing. The International Electrotechnical Commission released a 3-part IEC 61672 standard of the specifications of sound level meters in 2013, and it is adopted by the standards organizations of many countries. This first installment of the tutorial series references this international standard and discusses basic acoustics concepts, calibration principles, and key functions of sound level meters in the application of audiometric calibration. Subsequent installments will discuss how to measure the ambient noise levels, how to determine whether a test room is suitable for testing hearing thresholds using different transducers, and how to determine whether different transducers of audiometers meet the national or international standards.</p></div>\",\"PeriodicalId\":49175,\"journal\":{\"name\":\"Journal of Communication Disorders\",\"volume\":\"101 \",\"pages\":\"Article 106300\"},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Communication Disorders\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0021992422001186\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Communication Disorders","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0021992422001186","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

校准是听力学实践的一个重要组成部分,以确保听力测试设备的准确性以及测试结果在不同诊所和国家之间的可传递性。检查设备准确性和环境噪声水平的能力使临床医生能够监测其设备的功能,减少测试环境中的噪声干扰,并对其测试结果有信心,尤其是在人道主义或现场测试环境中。声级计是测量换能器和听力测试室声压级的主要仪器。国际电工委员会于2013年发布了由三部分组成的IEC 61672声级计规范标准,并被许多国家的标准组织采用。本系列教程的第一部分参考了这一国际标准,讨论了声级计在听力校准应用中的基本声学概念、校准原理和关键功能。后续部分将讨论如何测量环境噪声水平,如何确定测试室是否适合使用不同的换能器测试听力阈值,以及如何确定听力计的不同换能器是否符合国家或国际标准。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Calibration matters: I. Sound level meter basics

Calibration is an essential component of audiology practice to ensure the accuracy of the equipment for audiometric tests and the transferability of test results across different clinics and countries. The ability to check the accuracy of the equipment and the ambient noise levels allows clinicians to monitor the functions of their equipment, to reduce noise distractors in the testing environment, and to have confidence in their test results, especially in humanitarian or field test settings. Sound level meters are the primary instruments to measure the sound pressure levels of the transducers and the test rooms used for audiometric testing. The International Electrotechnical Commission released a 3-part IEC 61672 standard of the specifications of sound level meters in 2013, and it is adopted by the standards organizations of many countries. This first installment of the tutorial series references this international standard and discusses basic acoustics concepts, calibration principles, and key functions of sound level meters in the application of audiometric calibration. Subsequent installments will discuss how to measure the ambient noise levels, how to determine whether a test room is suitable for testing hearing thresholds using different transducers, and how to determine whether different transducers of audiometers meet the national or international standards.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Communication Disorders
Journal of Communication Disorders AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY-REHABILITATION
CiteScore
3.30
自引率
5.90%
发文量
71
审稿时长
>12 weeks
期刊介绍: The Journal of Communication Disorders publishes original articles on topics related to disorders of speech, language and hearing. Authors are encouraged to submit reports of experimental or descriptive investigations (research articles), review articles, tutorials or discussion papers, or letters to the editor ("short communications"). Please note that we do not accept case studies unless they conform to the principles of single-subject experimental design. Special issues are published periodically on timely and clinically relevant topics.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信