试验界面对健康成人呼吸试验中呼吸肌活动和肺功能的影响:一项初步研究。

Elaheh Sajjadi, Patrick C Mabe, Yasin B Seven, Barbara K Smith
{"title":"试验界面对健康成人呼吸试验中呼吸肌活动和肺功能的影响:一项初步研究。","authors":"Elaheh Sajjadi,&nbsp;Patrick C Mabe,&nbsp;Yasin B Seven,&nbsp;Barbara K Smith","doi":"10.1097/cpt.0000000000000183","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The mouthpiece is the standard interface for spirometry tests. Although the use of a mouthpiece can be challenging for patients with orofacial weakness, maintaining a proper seal with a facemask can be an issue for healthy individuals during forceful efforts. We compared respiratory muscle activity and tests using a mouthpiece and facemask in healthy adults to investigate whether they can be used interchangeably.</p><p><strong>Methods: </strong>In this observational study, subjects (n=12) completed forced vital capacity, maximal respiratory pressure, and peak cough flow with a mouthpiece and facemask. Root mean square values of the genioglossus, diaphragm, scalene, and sternocleidomastoid were compared between conditions.</p><p><strong>Results: </strong>When switching from a mouthpiece to a facemask, significantly higher values were seen for peak cough flow (average bias= -54.36 L/min, p<0.05) and the difference seen with MEP and MIP were clinically significant (average bias: MEP=27.33, MIP=-5.2). Additionally, submental activity was significantly greater when MIP was conducted with a mouthpiece. No significant differences were seen in respiratory muscle activity during resting breathing or spirometry.</p><p><strong>Conclusion: </strong>There are clinically significant differences with cough and MEP tests and neck muscles are activated differently based on interface. Considering the small sample size, our findings suggest a facemask may be used to complete some PFTs.</p>","PeriodicalId":72526,"journal":{"name":"Cardiopulmonary physical therapy journal","volume":"33 2","pages":"87-95"},"PeriodicalIF":0.0000,"publicationDate":"2022-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9488548/pdf/nihms-1738734.pdf","citationCount":"1","resultStr":"{\"title\":\"Effect of Test Interface on Respiratory Muscle Activity and Pulmonary Function During Respiratory Testing in Healthy Adults: A Pilot Study.\",\"authors\":\"Elaheh Sajjadi,&nbsp;Patrick C Mabe,&nbsp;Yasin B Seven,&nbsp;Barbara K Smith\",\"doi\":\"10.1097/cpt.0000000000000183\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>The mouthpiece is the standard interface for spirometry tests. Although the use of a mouthpiece can be challenging for patients with orofacial weakness, maintaining a proper seal with a facemask can be an issue for healthy individuals during forceful efforts. We compared respiratory muscle activity and tests using a mouthpiece and facemask in healthy adults to investigate whether they can be used interchangeably.</p><p><strong>Methods: </strong>In this observational study, subjects (n=12) completed forced vital capacity, maximal respiratory pressure, and peak cough flow with a mouthpiece and facemask. Root mean square values of the genioglossus, diaphragm, scalene, and sternocleidomastoid were compared between conditions.</p><p><strong>Results: </strong>When switching from a mouthpiece to a facemask, significantly higher values were seen for peak cough flow (average bias= -54.36 L/min, p<0.05) and the difference seen with MEP and MIP were clinically significant (average bias: MEP=27.33, MIP=-5.2). Additionally, submental activity was significantly greater when MIP was conducted with a mouthpiece. No significant differences were seen in respiratory muscle activity during resting breathing or spirometry.</p><p><strong>Conclusion: </strong>There are clinically significant differences with cough and MEP tests and neck muscles are activated differently based on interface. Considering the small sample size, our findings suggest a facemask may be used to complete some PFTs.</p>\",\"PeriodicalId\":72526,\"journal\":{\"name\":\"Cardiopulmonary physical therapy journal\",\"volume\":\"33 2\",\"pages\":\"87-95\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9488548/pdf/nihms-1738734.pdf\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Cardiopulmonary physical therapy journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1097/cpt.0000000000000183\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cardiopulmonary physical therapy journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/cpt.0000000000000183","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

用途:该吸口是肺活量测定的标准接口。尽管对于口腔面部虚弱的患者来说,使用牙套可能是一项挑战,但对于健康的人来说,在用力的过程中,使用口罩保持适当的密封可能是一个问题。我们比较了健康成人的呼吸肌活动和使用口套和口罩的测试,以调查它们是否可以互换使用。方法:在本观察性研究中,受试者(n=12)在戴口罩和面罩的情况下完成了用力肺活量、最大呼吸压力和咳嗽峰值。比较两种情况下颏舌肌、膈肌、斜角肌和胸锁乳突肌的均方根值。结果:当从口套切换到口罩时,咳嗽流量峰值明显升高(平均偏差= -54.36 L/min)。结论:咳嗽和MEP试验在临床上存在显著差异,颈部肌肉的激活方式因界面不同而不同。考虑到样本量小,我们的研究结果表明,可以使用口罩来完成一些pft。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Effect of Test Interface on Respiratory Muscle Activity and Pulmonary Function During Respiratory Testing in Healthy Adults: A Pilot Study.

Effect of Test Interface on Respiratory Muscle Activity and Pulmonary Function During Respiratory Testing in Healthy Adults: A Pilot Study.

Purpose: The mouthpiece is the standard interface for spirometry tests. Although the use of a mouthpiece can be challenging for patients with orofacial weakness, maintaining a proper seal with a facemask can be an issue for healthy individuals during forceful efforts. We compared respiratory muscle activity and tests using a mouthpiece and facemask in healthy adults to investigate whether they can be used interchangeably.

Methods: In this observational study, subjects (n=12) completed forced vital capacity, maximal respiratory pressure, and peak cough flow with a mouthpiece and facemask. Root mean square values of the genioglossus, diaphragm, scalene, and sternocleidomastoid were compared between conditions.

Results: When switching from a mouthpiece to a facemask, significantly higher values were seen for peak cough flow (average bias= -54.36 L/min, p<0.05) and the difference seen with MEP and MIP were clinically significant (average bias: MEP=27.33, MIP=-5.2). Additionally, submental activity was significantly greater when MIP was conducted with a mouthpiece. No significant differences were seen in respiratory muscle activity during resting breathing or spirometry.

Conclusion: There are clinically significant differences with cough and MEP tests and neck muscles are activated differently based on interface. Considering the small sample size, our findings suggest a facemask may be used to complete some PFTs.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信