乙烷的核磁共振成像和测速

IF 2.624
Maria Anikeeva , Maitreyi Sangal , Andrey N. Pravdivtsev , Maryia S. Pravdivtseva , Eva Peschke , Oliver Speck , Jan-Bernd Hövener
{"title":"乙烷的核磁共振成像和测速","authors":"Maria Anikeeva ,&nbsp;Maitreyi Sangal ,&nbsp;Andrey N. Pravdivtsev ,&nbsp;Maryia S. Pravdivtseva ,&nbsp;Eva Peschke ,&nbsp;Oliver Speck ,&nbsp;Jan-Bernd Hövener","doi":"10.1016/j.jmro.2023.100137","DOIUrl":null,"url":null,"abstract":"<div><p>This study investigates the experimental conditions required for magnetic resonance imaging (MRI) of thermally polarized hydrocarbon gas, focusing on ethane. The nuclear magnetic resonance (NMR) spectra and relaxation properties of ethane were analysed at different pressures in the range from 1.5 to 6 bar at 7 T using <sup>1</sup>H NMR spectroscopy. The spin-lattice relaxation time (T<sub>1</sub>) and spin-spin relaxation time (T<sub>2</sub>) were measured, and their dependence on the pressure was determined, showing that both relaxation times increase with pressure. Using the estimated relaxation times, we adjusted parameters for imaging of static ethane using rapid acquisition with relaxation enhancement (RARE) and fast low-angle shot (FLASH). The signal-to-noise ratio (SNR) of ethane images was evaluated and compared to the calculation for the given range of pressures. Then, we imaged flowing gas using a 2D velocity-encoded pulse sequence, which is usually used for liquid flow studies. The MRI-measured flow rates are compared to those pre-set with a pump, showing good agreement in the slow flow range. Overall, the results provide insights into the feasibility of <sup>1</sup>H MRI for imaging and flow measurements of thermally polarized ethane.</p></div>","PeriodicalId":365,"journal":{"name":"Journal of Magnetic Resonance Open","volume":"16 ","pages":"Article 100137"},"PeriodicalIF":2.6240,"publicationDate":"2023-10-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2666441023000456/pdfft?md5=ee9e2d935852d4ca5b924b20bb456221&pid=1-s2.0-S2666441023000456-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Magnetic resonance imaging and velocimetry of ethane\",\"authors\":\"Maria Anikeeva ,&nbsp;Maitreyi Sangal ,&nbsp;Andrey N. Pravdivtsev ,&nbsp;Maryia S. Pravdivtseva ,&nbsp;Eva Peschke ,&nbsp;Oliver Speck ,&nbsp;Jan-Bernd Hövener\",\"doi\":\"10.1016/j.jmro.2023.100137\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>This study investigates the experimental conditions required for magnetic resonance imaging (MRI) of thermally polarized hydrocarbon gas, focusing on ethane. The nuclear magnetic resonance (NMR) spectra and relaxation properties of ethane were analysed at different pressures in the range from 1.5 to 6 bar at 7 T using <sup>1</sup>H NMR spectroscopy. The spin-lattice relaxation time (T<sub>1</sub>) and spin-spin relaxation time (T<sub>2</sub>) were measured, and their dependence on the pressure was determined, showing that both relaxation times increase with pressure. Using the estimated relaxation times, we adjusted parameters for imaging of static ethane using rapid acquisition with relaxation enhancement (RARE) and fast low-angle shot (FLASH). The signal-to-noise ratio (SNR) of ethane images was evaluated and compared to the calculation for the given range of pressures. Then, we imaged flowing gas using a 2D velocity-encoded pulse sequence, which is usually used for liquid flow studies. The MRI-measured flow rates are compared to those pre-set with a pump, showing good agreement in the slow flow range. Overall, the results provide insights into the feasibility of <sup>1</sup>H MRI for imaging and flow measurements of thermally polarized ethane.</p></div>\",\"PeriodicalId\":365,\"journal\":{\"name\":\"Journal of Magnetic Resonance Open\",\"volume\":\"16 \",\"pages\":\"Article 100137\"},\"PeriodicalIF\":2.6240,\"publicationDate\":\"2023-10-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S2666441023000456/pdfft?md5=ee9e2d935852d4ca5b924b20bb456221&pid=1-s2.0-S2666441023000456-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Magnetic Resonance Open\",\"FirstCategoryId\":\"1\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2666441023000456\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Magnetic Resonance Open","FirstCategoryId":"1","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666441023000456","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

以乙烷为研究对象,研究了热极化烃类气体的磁共振成像(MRI)所需的实验条件。在7 T 1.5 ~ 6 bar的不同压力下,用1H NMR谱分析了乙烷的核磁共振波谱和弛豫特性。测量了自旋-晶格弛豫时间(T1)和自旋-自旋弛豫时间(T2),并确定了它们与压力的依赖关系,结果表明,两者的弛豫时间都随压力的增加而增加。利用估计的弛豫时间,我们调整了静态乙烷成像的参数,采用快速弛豫增强采集(RARE)和快速低角度拍摄(FLASH)。评估了乙烷图像的信噪比(SNR),并与给定压力范围内的计算结果进行了比较。然后,我们使用二维速度编码脉冲序列对流动气体进行成像,这通常用于液体流动研究。mri测量的流量与预先设置的泵流量进行比较,在慢流量范围内显示出良好的一致性。总的来说,这些结果为1H MRI用于热极化乙烷成像和流量测量的可行性提供了见解。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Magnetic resonance imaging and velocimetry of ethane

Magnetic resonance imaging and velocimetry of ethane

This study investigates the experimental conditions required for magnetic resonance imaging (MRI) of thermally polarized hydrocarbon gas, focusing on ethane. The nuclear magnetic resonance (NMR) spectra and relaxation properties of ethane were analysed at different pressures in the range from 1.5 to 6 bar at 7 T using 1H NMR spectroscopy. The spin-lattice relaxation time (T1) and spin-spin relaxation time (T2) were measured, and their dependence on the pressure was determined, showing that both relaxation times increase with pressure. Using the estimated relaxation times, we adjusted parameters for imaging of static ethane using rapid acquisition with relaxation enhancement (RARE) and fast low-angle shot (FLASH). The signal-to-noise ratio (SNR) of ethane images was evaluated and compared to the calculation for the given range of pressures. Then, we imaged flowing gas using a 2D velocity-encoded pulse sequence, which is usually used for liquid flow studies. The MRI-measured flow rates are compared to those pre-set with a pump, showing good agreement in the slow flow range. Overall, the results provide insights into the feasibility of 1H MRI for imaging and flow measurements of thermally polarized ethane.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.90
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信