{"title":"超配筋混杂纤维增强聚合物混凝土梁柱破坏","authors":"A. Mirmiran, M. Shahawy, C. Khoury","doi":"10.14359/5616","DOIUrl":null,"url":null,"abstract":"Concrete-filled fiber reinforced polymer (FRP) tubes provide an alternative to conventional reinforced and prestressed concrete columns. The tube helps turn normal strength concrete core into a high performance concrete, i.e., one with high strength, ductility, and durability. The over-reinforcement in concrete-filled tubes helps avoid split rupture of the FRP reinforcement in tension, which is catastrophic in nature. A total of 8 concrete-filled FRP tubes were tested as beam-columns under a combination of axial and flexural loads. The tubes were 9 feet long, and had an outside diameter of 13-11/16 in. with a wall thickness of about 0.55 in.. The study showed that over-reinforcement concrete-filled FRP tubes generally behave well as beam columns. They deflect to a lesser extent than the corresponding under-reinforced sections. They are also more efficient than under-reinforced sections, because a small portion of their sectional capacity is consumed by secondary moments and P-delta effects. Their failure, while in compression, is considered to be gradual and progressive.","PeriodicalId":68258,"journal":{"name":"玻璃钢","volume":"40 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"1999-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Failure of Over-Reinforced Hybrid Fiber Reinforced Polymer Concrete Beam Columns\",\"authors\":\"A. Mirmiran, M. Shahawy, C. Khoury\",\"doi\":\"10.14359/5616\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Concrete-filled fiber reinforced polymer (FRP) tubes provide an alternative to conventional reinforced and prestressed concrete columns. The tube helps turn normal strength concrete core into a high performance concrete, i.e., one with high strength, ductility, and durability. The over-reinforcement in concrete-filled tubes helps avoid split rupture of the FRP reinforcement in tension, which is catastrophic in nature. A total of 8 concrete-filled FRP tubes were tested as beam-columns under a combination of axial and flexural loads. The tubes were 9 feet long, and had an outside diameter of 13-11/16 in. with a wall thickness of about 0.55 in.. The study showed that over-reinforcement concrete-filled FRP tubes generally behave well as beam columns. They deflect to a lesser extent than the corresponding under-reinforced sections. They are also more efficient than under-reinforced sections, because a small portion of their sectional capacity is consumed by secondary moments and P-delta effects. Their failure, while in compression, is considered to be gradual and progressive.\",\"PeriodicalId\":68258,\"journal\":{\"name\":\"玻璃钢\",\"volume\":\"40 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1999-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"玻璃钢\",\"FirstCategoryId\":\"1087\",\"ListUrlMain\":\"https://doi.org/10.14359/5616\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"玻璃钢","FirstCategoryId":"1087","ListUrlMain":"https://doi.org/10.14359/5616","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Failure of Over-Reinforced Hybrid Fiber Reinforced Polymer Concrete Beam Columns
Concrete-filled fiber reinforced polymer (FRP) tubes provide an alternative to conventional reinforced and prestressed concrete columns. The tube helps turn normal strength concrete core into a high performance concrete, i.e., one with high strength, ductility, and durability. The over-reinforcement in concrete-filled tubes helps avoid split rupture of the FRP reinforcement in tension, which is catastrophic in nature. A total of 8 concrete-filled FRP tubes were tested as beam-columns under a combination of axial and flexural loads. The tubes were 9 feet long, and had an outside diameter of 13-11/16 in. with a wall thickness of about 0.55 in.. The study showed that over-reinforcement concrete-filled FRP tubes generally behave well as beam columns. They deflect to a lesser extent than the corresponding under-reinforced sections. They are also more efficient than under-reinforced sections, because a small portion of their sectional capacity is consumed by secondary moments and P-delta effects. Their failure, while in compression, is considered to be gradual and progressive.