通过优化内部探针几何形状来最大化微透析采样

N. Torto, L. Gorton, E. Mikeladze, E. Csöregi, T. Laurell
{"title":"通过优化内部探针几何形状来最大化微透析采样","authors":"N. Torto, L. Gorton, E. Mikeladze, E. Csöregi, T. Laurell","doi":"10.1039/A901175G","DOIUrl":null,"url":null,"abstract":"An in-house microdialysis probe equipped with 3 different inner cannulae exhibiting different inner and outer radii was used to sample glucose, maltotriose, maltopentaose and maltoheptaose as model analytes in order to evaluate its performance by means of optimised internal probe geometry. The results were correlated to the inner cannula ratio (Rir), defined as the inner cannula’s inner radius divided by the inner cannula’s outer radius. Extraction fraction (EF) or relative recovery (RR) showed a dependency on Rir for all the investigated analytes at all the perfusion rates. The EF for glucose improved up to 10% for a nominal increase of 0.27 in Rir. The sensitivity of the EF of saccharides to Rir decreased with the size of molecule. Therefore the Rir represents a parameter that should be further investigated in order to maximise the performances of concentric type microdialysis probes.","PeriodicalId":7814,"journal":{"name":"Analytical Communications","volume":"8 1","pages":"171-174"},"PeriodicalIF":0.0000,"publicationDate":"1999-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"13","resultStr":"{\"title\":\"Maximising microdialysis sampling by optimising the internal probe geometry\",\"authors\":\"N. Torto, L. Gorton, E. Mikeladze, E. Csöregi, T. Laurell\",\"doi\":\"10.1039/A901175G\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"An in-house microdialysis probe equipped with 3 different inner cannulae exhibiting different inner and outer radii was used to sample glucose, maltotriose, maltopentaose and maltoheptaose as model analytes in order to evaluate its performance by means of optimised internal probe geometry. The results were correlated to the inner cannula ratio (Rir), defined as the inner cannula’s inner radius divided by the inner cannula’s outer radius. Extraction fraction (EF) or relative recovery (RR) showed a dependency on Rir for all the investigated analytes at all the perfusion rates. The EF for glucose improved up to 10% for a nominal increase of 0.27 in Rir. The sensitivity of the EF of saccharides to Rir decreased with the size of molecule. Therefore the Rir represents a parameter that should be further investigated in order to maximise the performances of concentric type microdialysis probes.\",\"PeriodicalId\":7814,\"journal\":{\"name\":\"Analytical Communications\",\"volume\":\"8 1\",\"pages\":\"171-174\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1999-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"13\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Analytical Communications\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1039/A901175G\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical Communications","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1039/A901175G","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 13

摘要

内部微透析探针配有3个不同的内管,具有不同的内外半径,用于将葡萄糖,麦芽糖糖,麦芽糖戊二糖和麦芽糖七糖作为模型分析物,以便通过优化的内部探针几何形状来评估其性能。结果与内套管比(Rir)相关,Rir定义为内套管的内半径除以内套管的外半径。提取分数(EF)或相对回收率(RR)对所有研究分析物在所有灌注速率下的Rir都有依赖性。在Rir中,葡萄糖的EF提高了10%,名义上增加了0.27。糖的EF对Rir的敏感性随分子的大小而降低。因此,Rir代表一个参数,应该进一步研究,以最大限度地提高同心型微透析探针的性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Maximising microdialysis sampling by optimising the internal probe geometry
An in-house microdialysis probe equipped with 3 different inner cannulae exhibiting different inner and outer radii was used to sample glucose, maltotriose, maltopentaose and maltoheptaose as model analytes in order to evaluate its performance by means of optimised internal probe geometry. The results were correlated to the inner cannula ratio (Rir), defined as the inner cannula’s inner radius divided by the inner cannula’s outer radius. Extraction fraction (EF) or relative recovery (RR) showed a dependency on Rir for all the investigated analytes at all the perfusion rates. The EF for glucose improved up to 10% for a nominal increase of 0.27 in Rir. The sensitivity of the EF of saccharides to Rir decreased with the size of molecule. Therefore the Rir represents a parameter that should be further investigated in order to maximise the performances of concentric type microdialysis probes.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信