主题演讲:增强现实显示器在指导心脏内介入治疗中的作用

T. Peters
{"title":"主题演讲:增强现实显示器在指导心脏内介入治疗中的作用","authors":"T. Peters","doi":"10.1109/ISMAR.2014.6948399","DOIUrl":null,"url":null,"abstract":"Many inter-cardiac interventions are performed either via open-heart surgery, or using minimally invasive approaches, where instrumentation is introduced into the cardiac chambers via the vascular system or heart wall. While many of the latter procedures are often employed under x-ray guidance, for some of these xray imaging is not appropriate, and ultrasound is the preferred intra-operative imaging modality. Two such procedures involves the repair of a mitral-valve leafet, and the replacement of aortic valves. Both employ instruments introduced into the heart via the apex. For the mitral procedure, the standard of care for this procedure employs a 3D Trans-esophageal echo (TEE) probe as guidance, but using primarily its bi-plane mode, with full 3D only being used sporadically. In spite of the clinical success of this procedure, many problems are encountered during the navigation of the instrument to the site of the therapy. To overcome these diffculties, we have developed a guidance platform that tracks the US probe and instrument, and augments the US mages with virtual elements representing the instrument and target, to optimise the navigation process. Results of using this approach on animal studies have demonstrated increased performance in multiple metrics, including total tool distance from ideal pathway, total navigation time, and total tool path lengths, by factors of 3,4, and 5 respectively, as well as a 40 fold reduction in the number of times an instrument intruded into potentially unsafe zones in the heart.","PeriodicalId":92225,"journal":{"name":"International Symposium on Mixed and Augmented Reality : (ISMAR) [proceedings]. IEEE and ACM International Symposium on Mixed and Augmented Reality","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2014-11-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Keynote address: The role of augmented reality displays for guiding intra-cardiac interventions\",\"authors\":\"T. Peters\",\"doi\":\"10.1109/ISMAR.2014.6948399\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Many inter-cardiac interventions are performed either via open-heart surgery, or using minimally invasive approaches, where instrumentation is introduced into the cardiac chambers via the vascular system or heart wall. While many of the latter procedures are often employed under x-ray guidance, for some of these xray imaging is not appropriate, and ultrasound is the preferred intra-operative imaging modality. Two such procedures involves the repair of a mitral-valve leafet, and the replacement of aortic valves. Both employ instruments introduced into the heart via the apex. For the mitral procedure, the standard of care for this procedure employs a 3D Trans-esophageal echo (TEE) probe as guidance, but using primarily its bi-plane mode, with full 3D only being used sporadically. In spite of the clinical success of this procedure, many problems are encountered during the navigation of the instrument to the site of the therapy. To overcome these diffculties, we have developed a guidance platform that tracks the US probe and instrument, and augments the US mages with virtual elements representing the instrument and target, to optimise the navigation process. Results of using this approach on animal studies have demonstrated increased performance in multiple metrics, including total tool distance from ideal pathway, total navigation time, and total tool path lengths, by factors of 3,4, and 5 respectively, as well as a 40 fold reduction in the number of times an instrument intruded into potentially unsafe zones in the heart.\",\"PeriodicalId\":92225,\"journal\":{\"name\":\"International Symposium on Mixed and Augmented Reality : (ISMAR) [proceedings]. IEEE and ACM International Symposium on Mixed and Augmented Reality\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-11-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Symposium on Mixed and Augmented Reality : (ISMAR) [proceedings]. IEEE and ACM International Symposium on Mixed and Augmented Reality\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISMAR.2014.6948399\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Symposium on Mixed and Augmented Reality : (ISMAR) [proceedings]. IEEE and ACM International Symposium on Mixed and Augmented Reality","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISMAR.2014.6948399","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

许多心脏间介入手术要么通过心内直视手术进行,要么采用微创方法,通过血管系统或心壁将仪器引入心室。虽然许多后一种手术通常在x线引导下进行,但其中一些x线成像并不合适,超声是首选的术中成像方式。这两种手术包括修复二尖瓣叶和更换主动脉瓣。这两种方法都采用通过心尖进入心脏的器械。对于二尖瓣手术,该手术的标准护理采用3D经食管回声(TEE)探头作为指导,但主要使用其双平面模式,全3D仅偶尔使用。尽管这种方法在临床上取得了成功,但在仪器导航到治疗部位的过程中遇到了许多问题。为了克服这些困难,我们开发了一个制导平台,跟踪美国探头和仪器,并用代表仪器和目标的虚拟元素增强美国图像,以优化导航过程。在动物研究中使用这种方法的结果表明,在多个指标上,包括工具与理想路径的总距离、总导航时间和总工具路径长度,分别以3、4和5的倍数增加了性能,并且仪器侵入心脏潜在不安全区域的次数减少了40倍。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Keynote address: The role of augmented reality displays for guiding intra-cardiac interventions
Many inter-cardiac interventions are performed either via open-heart surgery, or using minimally invasive approaches, where instrumentation is introduced into the cardiac chambers via the vascular system or heart wall. While many of the latter procedures are often employed under x-ray guidance, for some of these xray imaging is not appropriate, and ultrasound is the preferred intra-operative imaging modality. Two such procedures involves the repair of a mitral-valve leafet, and the replacement of aortic valves. Both employ instruments introduced into the heart via the apex. For the mitral procedure, the standard of care for this procedure employs a 3D Trans-esophageal echo (TEE) probe as guidance, but using primarily its bi-plane mode, with full 3D only being used sporadically. In spite of the clinical success of this procedure, many problems are encountered during the navigation of the instrument to the site of the therapy. To overcome these diffculties, we have developed a guidance platform that tracks the US probe and instrument, and augments the US mages with virtual elements representing the instrument and target, to optimise the navigation process. Results of using this approach on animal studies have demonstrated increased performance in multiple metrics, including total tool distance from ideal pathway, total navigation time, and total tool path lengths, by factors of 3,4, and 5 respectively, as well as a 40 fold reduction in the number of times an instrument intruded into potentially unsafe zones in the heart.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信