胎儿经小脑直径在埃及胎儿不同生长模式中检测GA的价值

M. Alalfy, O. Idris, H. Gaafar, Hany Saad, O. Nagy, Yossra Lasheen, Hadeer Hassan
{"title":"胎儿经小脑直径在埃及胎儿不同生长模式中检测GA的价值","authors":"M. Alalfy, O. Idris, H. Gaafar, Hany Saad, O. Nagy, Yossra Lasheen, Hadeer Hassan","doi":"10.14303/IMAGING-MEDICINE.1000073","DOIUrl":null,"url":null,"abstract":"Ultrasonographic assessment of fetal gestational age is very critical for clinical decision making in obstetrics, many fetal biometric parameters are extensively used but in this research study we mainly targeted transcerebellar diameter in second and third trimester among Egyptian population and its accuracy and clinical reliability to calculate fetal gestational age. Aim of the research: The main goal and corner stone purpose of this research was to measure the accuracy of the transcerebellar diameter Transcerebellar diameter in calculating the gestational age of fetuses among Egyptian population and if it is more accurate than other fetal biometric measurements (Biparietal diameter, Head circumference, Abdominal circumference, Femur Length) in gestations with no medical disorders or not and the additional different methodology implemented in this research in comparison to other studies was using the Transcerebellar diameter in diabetic mothers with macrosomic fetuses, in pregnant Egyptian ladies with hypertension during pregnancy that have growth restricted fetuses with evaluation of uteroplacental blood flow by Doppler flow indices confirming uteroplacental insufficiency, also in fetuses with congenital structural abnormalities and in cerebellar anomalies. Results: The IQR interquartile range of the discrepancy between menstrual and sonographic gestational ages was the least when Transcerebellar diameter, in comparison to Biparieteal Diameter, Head Circumference, Abdominal Circumference and Femur Length (0.43 mm, 1.27 mm, 1.0 mm, 1.56 mm and 1.28 mm, respectively). The difference, however, was statistically significant only when compared to that using Abdominal Circumference. Conclusion: We concluded that Transcerebellar diameter is the most accurate biometric measurement in both uncomplicated pregnancies and in complicated pregnancies with medical disorders such as Diabetes mellitus and hypertension especially when associated with fetal macrosomia or fetal intrauterine growth restriction and in structural abnormalities affecting organs other than cerebellum as the cerebellar growth is not affected by these circumstances.","PeriodicalId":13333,"journal":{"name":"Imaging in Medicine","volume":"34 1","pages":"131-138"},"PeriodicalIF":0.0000,"publicationDate":"2017-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"The value of fetal trans cerebellar diameter in detecting GA in different fetal growth patterns in Egyptian fetuses\",\"authors\":\"M. Alalfy, O. Idris, H. Gaafar, Hany Saad, O. Nagy, Yossra Lasheen, Hadeer Hassan\",\"doi\":\"10.14303/IMAGING-MEDICINE.1000073\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Ultrasonographic assessment of fetal gestational age is very critical for clinical decision making in obstetrics, many fetal biometric parameters are extensively used but in this research study we mainly targeted transcerebellar diameter in second and third trimester among Egyptian population and its accuracy and clinical reliability to calculate fetal gestational age. Aim of the research: The main goal and corner stone purpose of this research was to measure the accuracy of the transcerebellar diameter Transcerebellar diameter in calculating the gestational age of fetuses among Egyptian population and if it is more accurate than other fetal biometric measurements (Biparietal diameter, Head circumference, Abdominal circumference, Femur Length) in gestations with no medical disorders or not and the additional different methodology implemented in this research in comparison to other studies was using the Transcerebellar diameter in diabetic mothers with macrosomic fetuses, in pregnant Egyptian ladies with hypertension during pregnancy that have growth restricted fetuses with evaluation of uteroplacental blood flow by Doppler flow indices confirming uteroplacental insufficiency, also in fetuses with congenital structural abnormalities and in cerebellar anomalies. Results: The IQR interquartile range of the discrepancy between menstrual and sonographic gestational ages was the least when Transcerebellar diameter, in comparison to Biparieteal Diameter, Head Circumference, Abdominal Circumference and Femur Length (0.43 mm, 1.27 mm, 1.0 mm, 1.56 mm and 1.28 mm, respectively). The difference, however, was statistically significant only when compared to that using Abdominal Circumference. Conclusion: We concluded that Transcerebellar diameter is the most accurate biometric measurement in both uncomplicated pregnancies and in complicated pregnancies with medical disorders such as Diabetes mellitus and hypertension especially when associated with fetal macrosomia or fetal intrauterine growth restriction and in structural abnormalities affecting organs other than cerebellum as the cerebellar growth is not affected by these circumstances.\",\"PeriodicalId\":13333,\"journal\":{\"name\":\"Imaging in Medicine\",\"volume\":\"34 1\",\"pages\":\"131-138\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Imaging in Medicine\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.14303/IMAGING-MEDICINE.1000073\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Imaging in Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14303/IMAGING-MEDICINE.1000073","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

超声评估胎儿胎龄对产科临床决策至关重要,许多胎儿生物特征参数被广泛使用,但在本研究中,我们主要针对埃及人群妊娠中晚期经小脑直径及其计算胎儿胎龄的准确性和临床可靠性。研究目的:本研究的主要目标和基础目的是测量经小脑直径在计算埃及人口胎儿胎龄中的准确性,以及它是否比其他胎儿生物测量(双顶骨直径、头围、腹围、与其他研究相比,本研究采用的其他不同方法是,在患有巨大胎儿的糖尿病母亲中使用小脑径,在怀孕期间患有高血压且胎儿生长受限的埃及孕妇中使用多普勒血流指数评估子宫胎盘血流,确认子宫胎盘功能不全。也适用于先天性结构异常和小脑异常的胎儿。结果:经小脑径与双顶骨径、头围、腹围、股骨长(分别为0.43 mm、1.27 mm、1.0 mm、1.56 mm、1.28 mm)相比,经小脑径与超声胎龄之间的IQR四分位数差异最小。然而,这种差异只有在与使用腹围的数据相比时才有统计学意义。结论:我们得出结论,小脑经径是最准确的生物测量在无并发症妊娠和复杂的妊娠医学疾病,如糖尿病和高血压,特别是当胎儿巨大儿或胎儿宫内生长受限,以及结构异常影响器官以外的小脑的生长不受这些情况的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The value of fetal trans cerebellar diameter in detecting GA in different fetal growth patterns in Egyptian fetuses
Ultrasonographic assessment of fetal gestational age is very critical for clinical decision making in obstetrics, many fetal biometric parameters are extensively used but in this research study we mainly targeted transcerebellar diameter in second and third trimester among Egyptian population and its accuracy and clinical reliability to calculate fetal gestational age. Aim of the research: The main goal and corner stone purpose of this research was to measure the accuracy of the transcerebellar diameter Transcerebellar diameter in calculating the gestational age of fetuses among Egyptian population and if it is more accurate than other fetal biometric measurements (Biparietal diameter, Head circumference, Abdominal circumference, Femur Length) in gestations with no medical disorders or not and the additional different methodology implemented in this research in comparison to other studies was using the Transcerebellar diameter in diabetic mothers with macrosomic fetuses, in pregnant Egyptian ladies with hypertension during pregnancy that have growth restricted fetuses with evaluation of uteroplacental blood flow by Doppler flow indices confirming uteroplacental insufficiency, also in fetuses with congenital structural abnormalities and in cerebellar anomalies. Results: The IQR interquartile range of the discrepancy between menstrual and sonographic gestational ages was the least when Transcerebellar diameter, in comparison to Biparieteal Diameter, Head Circumference, Abdominal Circumference and Femur Length (0.43 mm, 1.27 mm, 1.0 mm, 1.56 mm and 1.28 mm, respectively). The difference, however, was statistically significant only when compared to that using Abdominal Circumference. Conclusion: We concluded that Transcerebellar diameter is the most accurate biometric measurement in both uncomplicated pregnancies and in complicated pregnancies with medical disorders such as Diabetes mellitus and hypertension especially when associated with fetal macrosomia or fetal intrauterine growth restriction and in structural abnormalities affecting organs other than cerebellum as the cerebellar growth is not affected by these circumstances.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信