{"title":"一体式微型牙种植体的o型环附着体:使用不同原始基质- o型环组合对固位力可重复性的体外分析","authors":"Samir Abou-Ayash,&nbsp;Martin Schimmel,&nbsp;Andreas Worni,&nbsp;Norbert Enkling","doi":"10.11607/ijp.7055","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To analyze the influence of pristine matrix and O-ring dimensions on retention force and reproducibility in single one-piece mini dental implants (MDIs) with ball patrices under in vitro conditions.</p><p><strong>Materials and methods: </strong>Three different matrix and O-ring combinations (MH1-MH3) were evaluated (n = 50 per group) on 1.8-mm-diameter implants. The matrices were manually mounted on the implants and were subsequently removed in a vertical linear manner using a metal pin with two strain gauges, recording the maximum force during disconnection. After five disconnections, the O-rings were exchanged, and the mean retention force was calculated, resulting in 50 values for each matrix and O-ring combination. Mean retention forces, SDs, and 95% CI were calculated. Analysis of variance was used to test the global differences, and post hoc pairwise comparisons were subsequently applied. The level of significance was set to P < .05.</p><p><strong>Results: </strong>ANOVA (global P < .0001) and pairwise comparisons (all P < .0001) demonstrated statistically significant differences among the three different matrix and O-ring combinations, with mean values of 5.18 N (MH 1), 6.73 (MH 2), and 9.08 (MH 3). Within each combination, retention force variations of > 1 N could not be demonstrated; ie, by exchanging O-rings, a similar retention force can be reestablished.</p><p><strong>Conclusion: </strong>Matrix and O-ring dimensions have a significant influence on retention forces in one-piece MDIs. Pristine O-rings demonstrated highly reproducible initial retention forces in all matrices.</p>","PeriodicalId":50292,"journal":{"name":"International Journal of Prosthodontics","volume":"36 1","pages":"59–62"},"PeriodicalIF":2.1000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"O-Ring Attachments on One-Piece Mini Dental Implants: In Vitro Analysis of Retention Force Reproducibility Using Different Pristine Matrix-O-Ring Combinations\",\"authors\":\"Samir Abou-Ayash,&nbsp;Martin Schimmel,&nbsp;Andreas Worni,&nbsp;Norbert Enkling\",\"doi\":\"10.11607/ijp.7055\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To analyze the influence of pristine matrix and O-ring dimensions on retention force and reproducibility in single one-piece mini dental implants (MDIs) with ball patrices under in vitro conditions.</p><p><strong>Materials and methods: </strong>Three different matrix and O-ring combinations (MH1-MH3) were evaluated (n = 50 per group) on 1.8-mm-diameter implants. The matrices were manually mounted on the implants and were subsequently removed in a vertical linear manner using a metal pin with two strain gauges, recording the maximum force during disconnection. After five disconnections, the O-rings were exchanged, and the mean retention force was calculated, resulting in 50 values for each matrix and O-ring combination. Mean retention forces, SDs, and 95% CI were calculated. Analysis of variance was used to test the global differences, and post hoc pairwise comparisons were subsequently applied. The level of significance was set to P < .05.</p><p><strong>Results: </strong>ANOVA (global P < .0001) and pairwise comparisons (all P < .0001) demonstrated statistically significant differences among the three different matrix and O-ring combinations, with mean values of 5.18 N (MH 1), 6.73 (MH 2), and 9.08 (MH 3). Within each combination, retention force variations of > 1 N could not be demonstrated; ie, by exchanging O-rings, a similar retention force can be reestablished.</p><p><strong>Conclusion: </strong>Matrix and O-ring dimensions have a significant influence on retention forces in one-piece MDIs. Pristine O-rings demonstrated highly reproducible initial retention forces in all matrices.</p>\",\"PeriodicalId\":50292,\"journal\":{\"name\":\"International Journal of Prosthodontics\",\"volume\":\"36 1\",\"pages\":\"59–62\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Prosthodontics\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.11607/ijp.7055\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Prosthodontics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.11607/ijp.7055","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 1

摘要

目的:分析体外条件下原始基质和o形环尺寸对单片球形微型种植体固位力和再现性的影响。材料和方法:在直径1.8 mm的种植体上评估三种不同的基质和o型环组合(MH1-MH3)(每组n = 50)。将基质手动安装在植入物上,随后使用带两个应变计的金属销钉以垂直线性方式移除,记录断开时的最大力。五次断开后,交换o形圈,计算平均保持力,得到每个矩阵和o形圈组合的50个值。计算平均固位力、SDs和95% CI。方差分析用于检验整体差异,随后应用事后两两比较。显著性水平设为P < 0.05。结果:方差分析(总P < 0.0001)和两两比较(均P < 0.0001)显示,三种不同的矩阵和o型环组合之间存在统计学差异,平均值分别为5.18 N (MH 1)、6.73 N (MH 2)和9.08 N (MH 3)。在每种组合中,无法显示> 1 N的固位力变化;即,通过交换o形环,可以重新建立类似的保持力。结论:矩阵和o形环尺寸对一体式吸入器固位力有显著影响。原始o型环在所有基质中表现出高度可复制的初始保留力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
O-Ring Attachments on One-Piece Mini Dental Implants: In Vitro Analysis of Retention Force Reproducibility Using Different Pristine Matrix-O-Ring Combinations

Purpose: To analyze the influence of pristine matrix and O-ring dimensions on retention force and reproducibility in single one-piece mini dental implants (MDIs) with ball patrices under in vitro conditions.

Materials and methods: Three different matrix and O-ring combinations (MH1-MH3) were evaluated (n = 50 per group) on 1.8-mm-diameter implants. The matrices were manually mounted on the implants and were subsequently removed in a vertical linear manner using a metal pin with two strain gauges, recording the maximum force during disconnection. After five disconnections, the O-rings were exchanged, and the mean retention force was calculated, resulting in 50 values for each matrix and O-ring combination. Mean retention forces, SDs, and 95% CI were calculated. Analysis of variance was used to test the global differences, and post hoc pairwise comparisons were subsequently applied. The level of significance was set to P < .05.

Results: ANOVA (global P < .0001) and pairwise comparisons (all P < .0001) demonstrated statistically significant differences among the three different matrix and O-ring combinations, with mean values of 5.18 N (MH 1), 6.73 (MH 2), and 9.08 (MH 3). Within each combination, retention force variations of > 1 N could not be demonstrated; ie, by exchanging O-rings, a similar retention force can be reestablished.

Conclusion: Matrix and O-ring dimensions have a significant influence on retention forces in one-piece MDIs. Pristine O-rings demonstrated highly reproducible initial retention forces in all matrices.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
International Journal of Prosthodontics
International Journal of Prosthodontics 医学-牙科与口腔外科
CiteScore
3.20
自引率
4.30%
发文量
82
审稿时长
6-12 weeks
期刊介绍: Official Journal of the European Association for Osseointegration (EAO), the International College of Prosthodontists (ICP), the German Society of Prosthodontics and Dental Materials Science (DGPro), and the Italian Academy of Prosthetic Dentistry (AIOP) Prosthodontics demands a clinical research emphasis on patient- and dentist-mediated concerns in the management of oral rehabilitation needs. It is about making and implementing the best clinical decisions to enhance patients'' quality of life via applied biologic architecture - a role that far exceeds that of traditional prosthetic dentistry, with its emphasis on materials and techniques. The International Journal of Prosthodontics is dedicated to exploring and developing this conceptual shift in the role of today''s prosthodontist, clinician, and educator alike. The editorial board is composed of a distinguished team of leading international scholars.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信