减压双绞线电缆局部放电活动射频信号与电信号的比较

M. Given, R. Mason, M. Judd, P. McGlone, I. Timoshkin, M. Wilson
{"title":"减压双绞线电缆局部放电活动射频信号与电信号的比较","authors":"M. Given, R. Mason, M. Judd, P. McGlone, I. Timoshkin, M. Wilson","doi":"10.1109/CEIDP.2011.6232707","DOIUrl":null,"url":null,"abstract":"A pressure-controlled test facility has been set up that allows the PD behaviour of polymer insulated twisted pair samples exposed to 50 Hz AC voltages in the range of 0 to 10 kV to be characterised. Resulting PD activity is quantified using the methods defined in IEC standard 60270 and by using a simple monopole antenna to detect the RF signals excited inside the pressure vessel by the discharges. This paper gives the results of preliminary tests performed on samples of wire insulated with Ethylenetetraflourethylene, Silicon Rubber and Polyvinylchloride in the pressure range between 103 and 105 Pa in atmospheric air. The dependence of PD inception voltage on the environmental pressure is reported. Changes in the behaviour of the PD activity; the correlations between the RF and electrical measurements and the frequency components of the RF signals as the applied voltage and pressure are varied are characterised and discussed.","PeriodicalId":6317,"journal":{"name":"2011 Annual Report Conference on Electrical Insulation and Dielectric Phenomena","volume":"33 1","pages":"514-517"},"PeriodicalIF":0.0000,"publicationDate":"2011-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Comparison between RF and electrical signals from the partial discharge activity of twisted pair cables at reduced pressures\",\"authors\":\"M. Given, R. Mason, M. Judd, P. McGlone, I. Timoshkin, M. Wilson\",\"doi\":\"10.1109/CEIDP.2011.6232707\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A pressure-controlled test facility has been set up that allows the PD behaviour of polymer insulated twisted pair samples exposed to 50 Hz AC voltages in the range of 0 to 10 kV to be characterised. Resulting PD activity is quantified using the methods defined in IEC standard 60270 and by using a simple monopole antenna to detect the RF signals excited inside the pressure vessel by the discharges. This paper gives the results of preliminary tests performed on samples of wire insulated with Ethylenetetraflourethylene, Silicon Rubber and Polyvinylchloride in the pressure range between 103 and 105 Pa in atmospheric air. The dependence of PD inception voltage on the environmental pressure is reported. Changes in the behaviour of the PD activity; the correlations between the RF and electrical measurements and the frequency components of the RF signals as the applied voltage and pressure are varied are characterised and discussed.\",\"PeriodicalId\":6317,\"journal\":{\"name\":\"2011 Annual Report Conference on Electrical Insulation and Dielectric Phenomena\",\"volume\":\"33 1\",\"pages\":\"514-517\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 Annual Report Conference on Electrical Insulation and Dielectric Phenomena\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CEIDP.2011.6232707\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 Annual Report Conference on Electrical Insulation and Dielectric Phenomena","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIDP.2011.6232707","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

建立了一个压力控制测试设备,可以对暴露在0至10 kV范围内的50 Hz交流电压下的聚合物绝缘双绞线样品的PD行为进行表征。使用IEC标准60270中定义的方法和使用简单的单极天线来检测放电在压力容器内激发的射频信号,从而量化PD活度。本文给出了用乙烯四氟乙烯、硅橡胶和聚氯乙烯绝缘的电线样品在103 ~ 105pa大气压范围内的初步试验结果。本文报道了局部放电起始电压与环境压力的关系。PD活动行为的改变;描述和讨论了射频和电测量之间的相关性以及射频信号的频率成分随施加电压和压力的变化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Comparison between RF and electrical signals from the partial discharge activity of twisted pair cables at reduced pressures
A pressure-controlled test facility has been set up that allows the PD behaviour of polymer insulated twisted pair samples exposed to 50 Hz AC voltages in the range of 0 to 10 kV to be characterised. Resulting PD activity is quantified using the methods defined in IEC standard 60270 and by using a simple monopole antenna to detect the RF signals excited inside the pressure vessel by the discharges. This paper gives the results of preliminary tests performed on samples of wire insulated with Ethylenetetraflourethylene, Silicon Rubber and Polyvinylchloride in the pressure range between 103 and 105 Pa in atmospheric air. The dependence of PD inception voltage on the environmental pressure is reported. Changes in the behaviour of the PD activity; the correlations between the RF and electrical measurements and the frequency components of the RF signals as the applied voltage and pressure are varied are characterised and discussed.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信