{"title":"照明支路的谐波衰减放大效应","authors":"G. Malagón-Carvajal, C. Duarte, G. Ordóñez-Plata, C. Almeida, N. Kagan","doi":"10.1109/ICRERA.2017.8191280","DOIUrl":null,"url":null,"abstract":"The Compact Fluorescent Lamps (CFLs) are widely adopted in residential and commercial sector. This adoption is proposed following the energy conservation and environmental protection efforts. Despite, the CFLs consume low power, many users using these loads can cause a harmonic impact depending of the Attenuation-Amplification Effect. For instance, if this Effect is neglected (e.g., using Harmonic Current Source Model-HCSM), the collective harmonic current of these loads can be poorly estimated and the methods used to reduce harmonic distortion and to improve the power quality can be insufficient. This work proposes a Total Attenuation-Amplification Factor (TAF Index) to assess the relation with the widely adopted THDI Index. Likewise, this work analyses 1575 voltage and current measurements studying the variation incidence of wire length, distortion and voltage regulation on the Attenuation-Amplification Effect for a single CFL connected at the same time. Thus, this Effect is also assessed on 37 CFLs connected one by one using a CFL Time Domain Model. The results show low incidence on the Attenuation-Amplification Effect when a single load is fed and the voltage regulation and wire length of the branch circuit are varied. However, based on simulations an Amplification Effect is presented when several CFLs are connected in parallel configuration on distorted supply voltage.","PeriodicalId":6535,"journal":{"name":"2017 IEEE 6th International Conference on Renewable Energy Research and Applications (ICRERA)","volume":"42 1","pages":"283-289"},"PeriodicalIF":0.0000,"publicationDate":"2017-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Harmonic attenuation-amplification effect on lighting branch circuits\",\"authors\":\"G. Malagón-Carvajal, C. Duarte, G. Ordóñez-Plata, C. Almeida, N. Kagan\",\"doi\":\"10.1109/ICRERA.2017.8191280\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The Compact Fluorescent Lamps (CFLs) are widely adopted in residential and commercial sector. This adoption is proposed following the energy conservation and environmental protection efforts. Despite, the CFLs consume low power, many users using these loads can cause a harmonic impact depending of the Attenuation-Amplification Effect. For instance, if this Effect is neglected (e.g., using Harmonic Current Source Model-HCSM), the collective harmonic current of these loads can be poorly estimated and the methods used to reduce harmonic distortion and to improve the power quality can be insufficient. This work proposes a Total Attenuation-Amplification Factor (TAF Index) to assess the relation with the widely adopted THDI Index. Likewise, this work analyses 1575 voltage and current measurements studying the variation incidence of wire length, distortion and voltage regulation on the Attenuation-Amplification Effect for a single CFL connected at the same time. Thus, this Effect is also assessed on 37 CFLs connected one by one using a CFL Time Domain Model. The results show low incidence on the Attenuation-Amplification Effect when a single load is fed and the voltage regulation and wire length of the branch circuit are varied. However, based on simulations an Amplification Effect is presented when several CFLs are connected in parallel configuration on distorted supply voltage.\",\"PeriodicalId\":6535,\"journal\":{\"name\":\"2017 IEEE 6th International Conference on Renewable Energy Research and Applications (ICRERA)\",\"volume\":\"42 1\",\"pages\":\"283-289\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 IEEE 6th International Conference on Renewable Energy Research and Applications (ICRERA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICRERA.2017.8191280\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 IEEE 6th International Conference on Renewable Energy Research and Applications (ICRERA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICRERA.2017.8191280","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

紧凑型荧光灯(cfl)广泛应用于住宅和商业领域。这是在节约能源和保护环境的努力下提出的。尽管节能灯功耗低,但许多使用这些负载的用户可能会产生谐波影响,这取决于衰减放大效应。例如,如果忽略这种影响(例如,使用谐波电流源模型- hcsm),则这些负载的集体谐波电流可能无法准确估计,并且用于减少谐波失真和改善电能质量的方法可能不足。这项工作提出了一个总衰减放大系数(TAF指数)来评估与广泛采用的THDI指数的关系。同样,本文分析了1575个电压和电流测量结果,研究了导线长度、畸变和电压调节对单个CFL同时连接的衰减-放大效应的变化发生率。因此,这种影响也被评估在37节能灯一个接一个连接使用节能灯时域模型。结果表明,在单负载供电和支路稳压及导线长度变化的情况下,衰减放大效应的发生率较低。然而,仿真结果表明,在电源电压畸变的情况下,多个节能灯并联时存在放大效应。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Harmonic attenuation-amplification effect on lighting branch circuits
The Compact Fluorescent Lamps (CFLs) are widely adopted in residential and commercial sector. This adoption is proposed following the energy conservation and environmental protection efforts. Despite, the CFLs consume low power, many users using these loads can cause a harmonic impact depending of the Attenuation-Amplification Effect. For instance, if this Effect is neglected (e.g., using Harmonic Current Source Model-HCSM), the collective harmonic current of these loads can be poorly estimated and the methods used to reduce harmonic distortion and to improve the power quality can be insufficient. This work proposes a Total Attenuation-Amplification Factor (TAF Index) to assess the relation with the widely adopted THDI Index. Likewise, this work analyses 1575 voltage and current measurements studying the variation incidence of wire length, distortion and voltage regulation on the Attenuation-Amplification Effect for a single CFL connected at the same time. Thus, this Effect is also assessed on 37 CFLs connected one by one using a CFL Time Domain Model. The results show low incidence on the Attenuation-Amplification Effect when a single load is fed and the voltage regulation and wire length of the branch circuit are varied. However, based on simulations an Amplification Effect is presented when several CFLs are connected in parallel configuration on distorted supply voltage.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信