根管封闭器放射不透明的比较研究

Tae-Min Kim, Seo-Kyoung Kim, In-Nam Hwang, Y. Hwang, B. Kang, Suk-Ja Yoon, Jae-Seo Lee, W. Oh
{"title":"根管封闭器放射不透明的比较研究","authors":"Tae-Min Kim, Seo-Kyoung Kim, In-Nam Hwang, Y. Hwang, B. Kang, Suk-Ja Yoon, Jae-Seo Lee, W. Oh","doi":"10.5395/JKACD.2009.34.1.061","DOIUrl":null,"url":null,"abstract":"This study was performed to assess the radiopacity of a variety of root canal sealers according to the specification concerning root canal sealers. Ten materials including Tubli-. Kerr Pulp Canal , AH , AH , AH plus , Ad sea . , , ZOB , and dentin were evaluated in this study. In the first part, densitometric reading of an each step of aluminum step wedge on occlusal film was performed at different voltage and exposure time. In the second part, ten specimens were radiographed simultaneously with an aluminum step wedges on the occlusal films under decided condition. The mean radiographic density values of the materials were transformed into radiopacity expressed equivalent thickness of aluminum (mm Al). The following results were obtained. 1. Among the various conditions, the appropriate voltage and exposure time that meet the requirement density was 60 kVp at 0.2 s 2. All of the materials had greater radiopacity than 3 mm Al requirement of ANSI/ADA specification No. 57 (2000) and ISO No. 6876 (2001) standards. 3. The radiopacity of materials increased as thickness of materials increased. 4. The mm Al value of each specimen at 1mm in thickness has a significant difference in the statistics. It suggests that root canal sealers have a sufficient radiopacity that meet the requirement.","PeriodicalId":21126,"journal":{"name":"Restorative Dentistry and Endodontics","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2009-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"A COMPARATIVE STUDY ON RADIOPACITY OF ROOT CANAL SEALERS\",\"authors\":\"Tae-Min Kim, Seo-Kyoung Kim, In-Nam Hwang, Y. Hwang, B. Kang, Suk-Ja Yoon, Jae-Seo Lee, W. Oh\",\"doi\":\"10.5395/JKACD.2009.34.1.061\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This study was performed to assess the radiopacity of a variety of root canal sealers according to the specification concerning root canal sealers. Ten materials including Tubli-. Kerr Pulp Canal , AH , AH , AH plus , Ad sea . , , ZOB , and dentin were evaluated in this study. In the first part, densitometric reading of an each step of aluminum step wedge on occlusal film was performed at different voltage and exposure time. In the second part, ten specimens were radiographed simultaneously with an aluminum step wedges on the occlusal films under decided condition. The mean radiographic density values of the materials were transformed into radiopacity expressed equivalent thickness of aluminum (mm Al). The following results were obtained. 1. Among the various conditions, the appropriate voltage and exposure time that meet the requirement density was 60 kVp at 0.2 s 2. All of the materials had greater radiopacity than 3 mm Al requirement of ANSI/ADA specification No. 57 (2000) and ISO No. 6876 (2001) standards. 3. The radiopacity of materials increased as thickness of materials increased. 4. The mm Al value of each specimen at 1mm in thickness has a significant difference in the statistics. It suggests that root canal sealers have a sufficient radiopacity that meet the requirement.\",\"PeriodicalId\":21126,\"journal\":{\"name\":\"Restorative Dentistry and Endodontics\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Restorative Dentistry and Endodontics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5395/JKACD.2009.34.1.061\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Restorative Dentistry and Endodontics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5395/JKACD.2009.34.1.061","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

本研究是根据有关根管密封器的规范来评估各种根管密封器的不透光性。包括Tubli在内的十种材料。Kerr Pulp Canal, AH, AH +, Ad sea。在本研究中评估了ZOB和牙本质。第一部分,在不同的电压和曝光时间下,对各台阶的铝台阶楔在咬合膜上进行密度测量。第二部分,在确定的条件下,用铝台阶楔在咬合膜上同时对10个标本进行x线摄影。将材料的平均射线照相密度值转换为表示等效铝厚度(mm Al)的射线不透明度。得到了以下结果:1. 在各种条件中,满足密度要求的合适电压和曝光时间为60 kVp, 0.2 s 2。所有材料的辐射不透明度均高于ANSI/ADA规范57(2000)和ISO 6876(2001)标准的3毫米铝要求。3.材料的对射线不透明度随材料厚度的增加而增加。4. 各试样在厚度为1mm时的mm Al值在统计上有显著差异。提示根管封闭器具有足够的放射不透性,满足要求。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A COMPARATIVE STUDY ON RADIOPACITY OF ROOT CANAL SEALERS
This study was performed to assess the radiopacity of a variety of root canal sealers according to the specification concerning root canal sealers. Ten materials including Tubli-. Kerr Pulp Canal , AH , AH , AH plus , Ad sea . , , ZOB , and dentin were evaluated in this study. In the first part, densitometric reading of an each step of aluminum step wedge on occlusal film was performed at different voltage and exposure time. In the second part, ten specimens were radiographed simultaneously with an aluminum step wedges on the occlusal films under decided condition. The mean radiographic density values of the materials were transformed into radiopacity expressed equivalent thickness of aluminum (mm Al). The following results were obtained. 1. Among the various conditions, the appropriate voltage and exposure time that meet the requirement density was 60 kVp at 0.2 s 2. All of the materials had greater radiopacity than 3 mm Al requirement of ANSI/ADA specification No. 57 (2000) and ISO No. 6876 (2001) standards. 3. The radiopacity of materials increased as thickness of materials increased. 4. The mm Al value of each specimen at 1mm in thickness has a significant difference in the statistics. It suggests that root canal sealers have a sufficient radiopacity that meet the requirement.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信