波长复用的激光束组合精度

夏蕾 Xia Lei, 韩旭东 Han Xu-dong, 邵俊峰 Shao Jun-feng
{"title":"波长复用的激光束组合精度","authors":"夏蕾 Xia Lei, 韩旭东 Han Xu-dong, 邵俊峰 Shao Jun-feng","doi":"10.3788/CO.20140705.0801","DOIUrl":null,"url":null,"abstract":"Double laser beam combination accuracy of wavelength multiplexing is carried in this article. Two beams with wavelengths of 532 nm and 515 nm are combined into one in the combination and detection system using light filter with special optical thin films,and the combination accuracy is detected. Based on this system,the corresponding theoretical model is established,and the comprehensive analysis on the error source and the value in combination and detection are given in this paper. When the pointing stability of both beams is 50 μrad,the theoretical value of combination accuracy is 14. 69″,and the proportion of pointing stability is99. 26%. The system gets an excellent anti interference ability against the unstable factor such as the error of centroid location( error rate 3 times),and the variation in accuracy rate is less than 2. 4 ‰. When the laser pointing stability is increased to 23. 51 μrad,the highest theoretical value of combination accuracy is 7. 09″and the proportion of pointing stability is 96. 77%. The system still has a high ability of anti-interference and the variation in the accuracy rate is less than 1%. Factors that affect the beam combination accuracy of near field and small power are laser beam pointing stability,mechanical adjustment and centroid location error are all the factors to affect the combination accuracy of the near field beam with low power,among which the laser pointing stability is the main factor. Adjusting the proportion of each factor,we can control the ability of anti interference of beam combination.","PeriodicalId":10133,"journal":{"name":"Chinese Journal of Optics and Applied Optics","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2014-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Laser beam combination accuracy of wavelength multiplexing\",\"authors\":\"夏蕾 Xia Lei, 韩旭东 Han Xu-dong, 邵俊峰 Shao Jun-feng\",\"doi\":\"10.3788/CO.20140705.0801\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Double laser beam combination accuracy of wavelength multiplexing is carried in this article. Two beams with wavelengths of 532 nm and 515 nm are combined into one in the combination and detection system using light filter with special optical thin films,and the combination accuracy is detected. Based on this system,the corresponding theoretical model is established,and the comprehensive analysis on the error source and the value in combination and detection are given in this paper. When the pointing stability of both beams is 50 μrad,the theoretical value of combination accuracy is 14. 69″,and the proportion of pointing stability is99. 26%. The system gets an excellent anti interference ability against the unstable factor such as the error of centroid location( error rate 3 times),and the variation in accuracy rate is less than 2. 4 ‰. When the laser pointing stability is increased to 23. 51 μrad,the highest theoretical value of combination accuracy is 7. 09″and the proportion of pointing stability is 96. 77%. The system still has a high ability of anti-interference and the variation in the accuracy rate is less than 1%. Factors that affect the beam combination accuracy of near field and small power are laser beam pointing stability,mechanical adjustment and centroid location error are all the factors to affect the combination accuracy of the near field beam with low power,among which the laser pointing stability is the main factor. Adjusting the proportion of each factor,we can control the ability of anti interference of beam combination.\",\"PeriodicalId\":10133,\"journal\":{\"name\":\"Chinese Journal of Optics and Applied Optics\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Chinese Journal of Optics and Applied Optics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3788/CO.20140705.0801\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Chinese Journal of Optics and Applied Optics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3788/CO.20140705.0801","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

本文对波长复用的双激光束组合精度进行了研究。在采用特殊光学薄膜滤光片的组合检测系统中,将波长为532 nm和515 nm的两束光束组合为一束,并检测组合精度。在该系统的基础上,建立了相应的理论模型,并对误差来源和组合检测中的值进行了综合分析。当两束指向稳定度为50 μrad时,组合精度的理论值为14。69″,指向稳定性比例为99。26%。该系统对质心定位误差等不稳定因素具有良好的抗干扰能力(错误率为3倍),准确率变化小于2。4‰。当激光指向稳定性提高到23。51 μrad时,组合精度理论值最高为7。09″,指向稳定性比例为96。77%。该系统仍然具有较高的抗干扰能力,准确率的变化小于1%。影响近场小功率光束组合精度的因素有:激光束指向稳定性、机械调节和质心定位误差都是影响低功率近场光束组合精度的因素,其中激光指向稳定性是影响组合精度的主要因素。通过调整各因素的比例,可以控制波束组合的抗干扰能力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Laser beam combination accuracy of wavelength multiplexing
Double laser beam combination accuracy of wavelength multiplexing is carried in this article. Two beams with wavelengths of 532 nm and 515 nm are combined into one in the combination and detection system using light filter with special optical thin films,and the combination accuracy is detected. Based on this system,the corresponding theoretical model is established,and the comprehensive analysis on the error source and the value in combination and detection are given in this paper. When the pointing stability of both beams is 50 μrad,the theoretical value of combination accuracy is 14. 69″,and the proportion of pointing stability is99. 26%. The system gets an excellent anti interference ability against the unstable factor such as the error of centroid location( error rate 3 times),and the variation in accuracy rate is less than 2. 4 ‰. When the laser pointing stability is increased to 23. 51 μrad,the highest theoretical value of combination accuracy is 7. 09″and the proportion of pointing stability is 96. 77%. The system still has a high ability of anti-interference and the variation in the accuracy rate is less than 1%. Factors that affect the beam combination accuracy of near field and small power are laser beam pointing stability,mechanical adjustment and centroid location error are all the factors to affect the combination accuracy of the near field beam with low power,among which the laser pointing stability is the main factor. Adjusting the proportion of each factor,we can control the ability of anti interference of beam combination.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信