一种用于体外体积估计的改进电压变化比(MVCR)

IF 0.2 Q4 ENGINEERING, MULTIDISCIPLINARY
Víctor Hugo Mosquera Leyton, C. F. Rengifo-Rodas
{"title":"一种用于体外体积估计的改进电压变化比(MVCR)","authors":"Víctor Hugo Mosquera Leyton, C. F. Rengifo-Rodas","doi":"10.17533/udea.redin.20220889","DOIUrl":null,"url":null,"abstract":"Electrical bioimpedance (EBI) is a non-invasive technique for monitoring bladder volume. The EBI approaches global impedance (GI), impedance ratio method (IRM), and voltage change ratio (VCR) have been successfully applied to detect changes in the volume of objects with constant but unknown conductivity. In this work, simulated and in-vitro experiments are used to compare the performance of these methods with respect to a new approach proposed by some authors and called modified VCR (MVCR). Experimental results indicated that GI, VCR, and MVCR indices increase when the volume of the object under study increases. On the other hand, no direct or inverse relationship between IRM and volume was observed. The coefficient of variation, defined as the interquartile range divided by the median of a set of measurements, was lower for MVCR, which indicates that the proposed approach is less sensitive to measurement noise than the other three methods.","PeriodicalId":42846,"journal":{"name":"Revista Facultad de Ingenieria, Universidad Pedagogica y Tecnologica de Colombia","volume":null,"pages":null},"PeriodicalIF":0.2000,"publicationDate":"2022-08-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A modified voltage changes ratio (MVCR) for in-vitro volume estimation\",\"authors\":\"Víctor Hugo Mosquera Leyton, C. F. Rengifo-Rodas\",\"doi\":\"10.17533/udea.redin.20220889\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Electrical bioimpedance (EBI) is a non-invasive technique for monitoring bladder volume. The EBI approaches global impedance (GI), impedance ratio method (IRM), and voltage change ratio (VCR) have been successfully applied to detect changes in the volume of objects with constant but unknown conductivity. In this work, simulated and in-vitro experiments are used to compare the performance of these methods with respect to a new approach proposed by some authors and called modified VCR (MVCR). Experimental results indicated that GI, VCR, and MVCR indices increase when the volume of the object under study increases. On the other hand, no direct or inverse relationship between IRM and volume was observed. The coefficient of variation, defined as the interquartile range divided by the median of a set of measurements, was lower for MVCR, which indicates that the proposed approach is less sensitive to measurement noise than the other three methods.\",\"PeriodicalId\":42846,\"journal\":{\"name\":\"Revista Facultad de Ingenieria, Universidad Pedagogica y Tecnologica de Colombia\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.2000,\"publicationDate\":\"2022-08-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Revista Facultad de Ingenieria, Universidad Pedagogica y Tecnologica de Colombia\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.17533/udea.redin.20220889\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista Facultad de Ingenieria, Universidad Pedagogica y Tecnologica de Colombia","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17533/udea.redin.20220889","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

摘要

电生物阻抗(EBI)是一种监测膀胱容量的无创技术。EBI方法的全局阻抗(GI)、阻抗比法(IRM)和电压变化率(VCR)已经成功地应用于检测恒定但未知电导率的物体的体积变化。在这项工作中,模拟和体外实验被用来比较这些方法的性能相对于一些作者提出的一种新方法,称为修改VCR (MVCR)。实验结果表明,GI、VCR和MVCR指标随着研究对象体积的增大而增大。另一方面,IRM与体积之间没有直接或负相关关系。MVCR的变异系数(定义为一组测量值的四分位数范围除以中位数)较低,这表明该方法对测量噪声的敏感性低于其他三种方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A modified voltage changes ratio (MVCR) for in-vitro volume estimation
Electrical bioimpedance (EBI) is a non-invasive technique for monitoring bladder volume. The EBI approaches global impedance (GI), impedance ratio method (IRM), and voltage change ratio (VCR) have been successfully applied to detect changes in the volume of objects with constant but unknown conductivity. In this work, simulated and in-vitro experiments are used to compare the performance of these methods with respect to a new approach proposed by some authors and called modified VCR (MVCR). Experimental results indicated that GI, VCR, and MVCR indices increase when the volume of the object under study increases. On the other hand, no direct or inverse relationship between IRM and volume was observed. The coefficient of variation, defined as the interquartile range divided by the median of a set of measurements, was lower for MVCR, which indicates that the proposed approach is less sensitive to measurement noise than the other three methods.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
审稿时长
8 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信