S. Mitra, Jiawei Xu, Akinori Matsumoto, K. Makinwa, C. Hoof, R. Yazicioglu
{"title":"用于干电极的700µW 8通道EEG/接触阻抗采集系统","authors":"S. Mitra, Jiawei Xu, Akinori Matsumoto, K. Makinwa, C. Hoof, R. Yazicioglu","doi":"10.1109/VLSIC.2012.6243793","DOIUrl":null,"url":null,"abstract":"A 700μW 8-channel active-electrode (AE) based EEG monitoring system is presented. The complete system consists of 9 AEs and a back-end analog signal processor. It is capable of continuously recording EEG signals and electrode-tissue contact impedance (ETI). The EEG channels have 1.2GΩ input impedance, 1.75μVrms noise (0.5-100Hz), 84dB CMRR, and can reject ±250mV of electrode offset, while consuming less than <;87μW (including ETI measurement). The system facilitates ambulatory use and patient comfort, while delivering high quality EEG signals.","PeriodicalId":6347,"journal":{"name":"2012 Symposium on VLSI Circuits (VLSIC)","volume":"57 1","pages":"68-69"},"PeriodicalIF":0.0000,"publicationDate":"2012-06-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"24","resultStr":"{\"title\":\"A 700µW 8-channel EEG/contact-impedance acquisition system for dry-electrodes\",\"authors\":\"S. Mitra, Jiawei Xu, Akinori Matsumoto, K. Makinwa, C. Hoof, R. Yazicioglu\",\"doi\":\"10.1109/VLSIC.2012.6243793\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A 700μW 8-channel active-electrode (AE) based EEG monitoring system is presented. The complete system consists of 9 AEs and a back-end analog signal processor. It is capable of continuously recording EEG signals and electrode-tissue contact impedance (ETI). The EEG channels have 1.2GΩ input impedance, 1.75μVrms noise (0.5-100Hz), 84dB CMRR, and can reject ±250mV of electrode offset, while consuming less than <;87μW (including ETI measurement). The system facilitates ambulatory use and patient comfort, while delivering high quality EEG signals.\",\"PeriodicalId\":6347,\"journal\":{\"name\":\"2012 Symposium on VLSI Circuits (VLSIC)\",\"volume\":\"57 1\",\"pages\":\"68-69\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-06-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"24\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 Symposium on VLSI Circuits (VLSIC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/VLSIC.2012.6243793\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 Symposium on VLSI Circuits (VLSIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/VLSIC.2012.6243793","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A 700µW 8-channel EEG/contact-impedance acquisition system for dry-electrodes
A 700μW 8-channel active-electrode (AE) based EEG monitoring system is presented. The complete system consists of 9 AEs and a back-end analog signal processor. It is capable of continuously recording EEG signals and electrode-tissue contact impedance (ETI). The EEG channels have 1.2GΩ input impedance, 1.75μVrms noise (0.5-100Hz), 84dB CMRR, and can reject ±250mV of electrode offset, while consuming less than <;87μW (including ETI measurement). The system facilitates ambulatory use and patient comfort, while delivering high quality EEG signals.