{"title":"一种基于粒子滤波的扩散率自适应成像心肌纤维结构重建方法","authors":"Jun Yin, Xuan Gao, Min Wu, Yan Liang","doi":"10.4018/ijec.304033","DOIUrl":null,"url":null,"abstract":"In order to explore the cause of characteristic change and pathological variation of myocardial fiber structure, the posterior probability distribution of fiber direction was described. To solve the problems of low computational efficiency and slow convergence of traditional particle filter, an adaptive particle filter myocardial fiber reconstruction algorithm based on diffusion anisotropy is proposed. This algorithm dynamically adjusts the number of particles and the disturbance intensity at the prediction stage according to the diffusion anisotropy values at different body elements. While ensuring the quality of state estimation, the computational complexity of the algorithm is reduced and the operating efficiency of the system is significantly improved. The experimental results show that the proposed method has strong anti-noise ability. While improving the accuracy of fiber reconstruction, the computational cost of the system decreases by 50%, which significantly improves the efficiency of the system. The proposed algorithm is good over traditional PF and STL approaches.","PeriodicalId":13957,"journal":{"name":"Int. J. e Collab.","volume":"43 1","pages":"1-11"},"PeriodicalIF":0.0000,"publicationDate":"2022-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Method for the Reconstruction of Myocardial Fiber Structure in Diffusivity Adaptive Imaging Based on Particle Filter\",\"authors\":\"Jun Yin, Xuan Gao, Min Wu, Yan Liang\",\"doi\":\"10.4018/ijec.304033\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In order to explore the cause of characteristic change and pathological variation of myocardial fiber structure, the posterior probability distribution of fiber direction was described. To solve the problems of low computational efficiency and slow convergence of traditional particle filter, an adaptive particle filter myocardial fiber reconstruction algorithm based on diffusion anisotropy is proposed. This algorithm dynamically adjusts the number of particles and the disturbance intensity at the prediction stage according to the diffusion anisotropy values at different body elements. While ensuring the quality of state estimation, the computational complexity of the algorithm is reduced and the operating efficiency of the system is significantly improved. The experimental results show that the proposed method has strong anti-noise ability. While improving the accuracy of fiber reconstruction, the computational cost of the system decreases by 50%, which significantly improves the efficiency of the system. The proposed algorithm is good over traditional PF and STL approaches.\",\"PeriodicalId\":13957,\"journal\":{\"name\":\"Int. J. e Collab.\",\"volume\":\"43 1\",\"pages\":\"1-11\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Int. J. e Collab.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4018/ijec.304033\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Int. J. e Collab.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4018/ijec.304033","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A Method for the Reconstruction of Myocardial Fiber Structure in Diffusivity Adaptive Imaging Based on Particle Filter
In order to explore the cause of characteristic change and pathological variation of myocardial fiber structure, the posterior probability distribution of fiber direction was described. To solve the problems of low computational efficiency and slow convergence of traditional particle filter, an adaptive particle filter myocardial fiber reconstruction algorithm based on diffusion anisotropy is proposed. This algorithm dynamically adjusts the number of particles and the disturbance intensity at the prediction stage according to the diffusion anisotropy values at different body elements. While ensuring the quality of state estimation, the computational complexity of the algorithm is reduced and the operating efficiency of the system is significantly improved. The experimental results show that the proposed method has strong anti-noise ability. While improving the accuracy of fiber reconstruction, the computational cost of the system decreases by 50%, which significantly improves the efficiency of the system. The proposed algorithm is good over traditional PF and STL approaches.